• 제목/요약/키워드: Grounding Electrode

검색결과 154건 처리시간 0.026초

지중송전계통의 접지특성분석에 관한 연구 (A Study on the Grounding Characteristics of Underground Transmission Power Canble Systems)

  • 정채균;홍동석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.482-484
    • /
    • 2001
  • Earth resistivity and changing of grounding electrode's shape are very important factor to reduce grounding resistance. Earth resistivity has different values according to property of soil and is effected by temperature, climate, and environment. This Paper describes the effect of the grounding resistance according to the grounding type such as driven rod, counterpoise grounding and mesh grounding. And also grounding resistance values with earth resistivity and shape of grounding electrode were represented in this paper.

  • PDF

Corrosion Performance of Cu Bonded Grounding-Electrode by Accelerated Corrosion Test

  • Choi, Sun Kyu;Kim, Kyung Chul
    • Corrosion Science and Technology
    • /
    • 제17권5호
    • /
    • pp.211-217
    • /
    • 2018
  • Natural degradation of grounding-electrode in soil environment should be monitored for several decades to predict the lifetime of the grounding electrode for efficient application and management. However, long-term studies for such electrodes have many practical limitations. The conventional accelerated corrosion test is unsuitable for such studies because simulated soil corrosion process cannot represent the actual soil environment. A preliminary experiment of accelerated corrosion test was conducted using existing test standards. The accelerated corrosion test that reflects the actual soil environment has been developed to evaluate corrosion performances of grounding-electrodes in a short period. Several test conditions with different chamber temperatures and salt spray were used to imitate actual field conditions based on ASTM B162, ASTM B117, and ISO 14993 standards. Accelerated degradation specimens of copper-bonded electrodes were made by the facile method and their corrosion performances were investigated. Their corrosion rates were calculated to $0.042{\mu}m/day$, $0.316{\mu}m/day$, and $0.11{\mu}m/day$, respectively. These results indicate that accelerated deterioration of grounding materials can be determined in a short period by using cyclic test condition with salt spray temperature of $50^{\circ}C$.

구조체접지극 활용을 위한 모형블록의 저항률 분석 (Resistivity Analysis of Model Block for Using of Structure Grounding Electrode)

  • 김성삼;정만길;최종규;고희석
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.40-45
    • /
    • 2007
  • 건축물의 기초를 구조체접지 및 대용접지극으로 활용하기 위한 기초실험으로 모형블록의 저항률 특성에 관해 검토하였다. 콘크리트와 몰탈의 모형블록을 제작 후 상온과 함수 상태에서 저항률을 측정하였으며, 저항률을 저감시키기 위해 접지저항 저감제를 혼합한 블록을 제작 하여 비교 하였다. 블록의 저항 값은 블록 저항률에 의해 가장 많은 영향을 받으며, 블록 저항률이 동일하거나 유사한 값일 때 대지저항률 값의 차이만큼 접지저항 값의 차이가 발생하였다.

반구형 실험모델을 이용한 대지표면 전위상승의 분석 (Analysis of the Ground Surface Potential Rise using a Hemisphere-Shaped Test Model)

  • 유재덕;조용승;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.208-213
    • /
    • 2010
  • This paper deal with an analysis of the ground surface potential profiles using a hemispherical scaled-model. Because it is very difficult to draw valid conclusions concerning a general grounding problem from actual field data, scale model tests can be used to determine the ground surface potential profile around the grounding electrodes according to the configuration of grounding electrodes. In this work, a hemispherical vessel with a diameter of 1,100 [mm] was employed to simulate uniform soil and CDEGS program was employed to compare the measured and simulated results. As a result, the ground surface potential around the grounding electrode was significantly raised and the ground surface potential at the just upper point of ground electrode particularly was higher than other points. The ground surface potential of counterpoise was higher than other grounding electrodes such as mesh and grounding rods and the ground surface potential strongly depends on the frequency responses of grounding electrodes. Also the results measured with the small-sized model were in reasonably agreement with the data obtained from simulation.

ETM 기법을 이용한 접지전극의 전위간섭 평가 (Assessment of Potential Interference between Grounding Electrodes Using ETM Method)

  • 길형준;김동욱;김동우;이기연;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.333-336
    • /
    • 2007
  • This paper deals with assessment of potential interference between grounding electrodes using ETM(Electrolytic Tank Modeling) method. When a test current flowed through grounding electrode, potential rise was measured and analyzed using an electrolytic tank in real time. In order to analyze the potential interference between grounding electrodes, ETM method was studies. Potential interference between isolated grounding electrodes was evaluated as functions of the separation distance between grounding electrodes and the configuration of grounding electrode to be induced. It was found that the separation distance between grounding electrodes in reducing the potential interference was a major factor.

  • PDF

전위상승에 대한 독립접지방식과 공통접지방식의 비교 (Comparison of Individual and Common Grounding Method for Potential Rise)

  • 길형준;김동욱;김동우;이기연;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.41-43
    • /
    • 2006
  • This paper deals with a comparison of individual and common grounding method for potential rise. When a test current flowed through grounding electrode, potential rise was measured and analyzed for grounding method using a electrolytic tank in real time. The grounding electrodes were designed and fabricated with ground rods on a scale of one-eightieth. Potential rises of individual grounding method were higher than those of common grounding method. The distributions of surface potential are dependent on the distance from grounding electrode.

  • PDF

Research on Assessment of Potential Interference between Individual Grounding Electrodes Using an Electrolytic Tank Modeling Method

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Choi, Chung-Seog
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.27-33
    • /
    • 2008
  • This paper deals with the assessment of potential interference between individual grounding electrodes using an Electrolytic Tank Modeling method. When a test current was passed through a grounding electrode, potential rise was measured and analyzed using an electrolytic tank in real time. In order to analyze the potential interference between grounding electrodes, a reduced scale modeling method was studied. Potential interference between isolated grounding electrodes was evaluated as a function of the separation distance between grounding electrodes and the configuration of grounding electrode to be induced. It was found that the separation distance between grounding electrodes was a major factor in reducing the potential interference.

접지저항(接地抵抗) 의감책(儀減策)에 관한 일방안(一方案) (A method for reducing grounding resistance)

  • 김태훈;백승도;김양수;배철한;김종철;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.351-353
    • /
    • 1997
  • In this paper, we investigate the grounding installation using grounding electrode into the earth in order to protect the power transmission line and transmission system and to improve the reliability of operations. Grounding electrode into the earth that has small grounding resistance is found to be very cost effective compare to other electrode systems by the ease of installation and making the earth damage small.

  • PDF

임펄스전류에 의한 매설지선의 과도임피던스특성에 대한 모의해석 (Simulated Analysis for the Transient Impedance Behaviors of Counterpoises Subjected to the Impulsive Currents)

  • 조정현;이복희
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1861-1868
    • /
    • 2009
  • A ground electrode subjected to lightning surge current shows the transient impedance behaviors. The ground electrode for protection against lightning should be evaluated in view of the transient grounding impedance and conventional grounding impedance, not ground resistance. The transient impedance characteristics of ground electrodes are influenced by the shape of ground electrode and the soil characteristics, as well as the waveform of lightning surge current. In order to propose a simulation method of analyzing the transient impedance characteristics of the grounding system in practical use, this paper suggests a theoretical analysis method of distributed parameter circuit model to simulate the transient impedance characteristics of counterpoise subjected to lightning surge current. EMTP and Matlab programs were employed to compute the transient grounding impedances of three counterpoises with different lengths. As a consequence, the simulated results using the proposed distributed parameter circuit model are in good agreement with the measured results.

대규모 접지전극 망의 접지성능 평가를 위한 겉보기저항곡선의 해석에 관한 연구 (A study on the Interpretation Technique of Fall-Of-Potential Curve for Grounding Performance Evaluation of a Large Grounding Electrode Network)

  • 최종기;유희영;이동일;정길조;김경철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.49-54
    • /
    • 2005
  • 접지저항의 측정은 접지극의 성능을 정량적으로 평가하는 가장 일반적인 방법이며, 여러 측정방법 중 전위강하 법은 대형 접지극의 저항측정에 많이 이용되는 방법이다. 그러나 접지극의 크기에 비례하여 측정선 길이도 길어져야 하므로, 대규모 접지전각의 경우 현장여건상 충분한 길이의 측정선을 펼치기가 곤란한 경우가 있을 수 있다. 본 논문에서는 여러 개의 접지망이 상호 연결되어 대규모의 접지극 네트워크를 형성하고 있어 충분한 길이의 전위강하법 측정선을 펼치는 것이 현실적으로 어려운 경우에 전위강하법 측정결과의 해석방법을 제시한다. 사례연구로서 상부댐 접지극과 약 2(km) 떨어져 있는 스위치야드 접지극이 상호 연결된 대형 접지극망에서 전위강하법 측정곡선 및 해석사례를 기술하였다.