• Title/Summary/Keyword: Ground temperature

Search Result 1,599, Processing Time 0.031 seconds

A Study on Specific of Ground Water Temperature Changes of the Small Scaled SCW GWHP System in Case of Heating (소규모 SCW 지중열 시스템의 난방시 지하수 온도 변화 특성에 관한 연구)

  • Yang, Seung-Jin;Lee, Won-Ho;Kim, Ju-Young;Hong, Won-Hwa;Ahn, Chang-whan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1347-1352
    • /
    • 2008
  • The SCW ground heat pump system releases ground energy from the ground water of ground heat exchanger. In other word, ground water is used to heating through releases ground energy which oneself has. But the thermal efficiency of system is going to down because repetitive process of ground water will lost ground energy in standing column well system and if heating load is continually increase, energy of ground water may be frozen or there are no benefits to use ground energy as it owes just little energy. To solve these problems, there are need to exchange water to the ground heat exchanger then the way will be used to maintain Efficiency continually as the way of to be supplied with fresh ground water into ground heat exchanger. However, this type causes waste of ground water. Therefore it is essential to discharge water to outside timely on a heat exchanger. Therefor through a study, find out the best time to discharge water to outside and exchange water to ground heat exchanger, and propose to the DB of design of the ground heat exchanger.

  • PDF

Temperature Compensation of Optical FBG Sensors Embedded Tendon for Long-term Monitoring of Tension Force of Ground Anchor (광섬유 센서 내장형 텐던을 이용한 그라운드 앵커의 장기 장력모니터링을 위한 온도보상)

  • Sung, Hyun-Jong;Kim, Young-Sang;Kim, Jae-Min;Park, Gui-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.13-25
    • /
    • 2012
  • Ground anchor method is one of the most popular reinforcing technology for slope in Korea. For the health monitoring of slope which is reinforced by permanent anchor for a long period, monitoring of the tension force of ground anchor is very important. However, since electromechanical sensors such as strain gauge and V/W type load cell are also subject to long-term risk as well as suffering from noise during long distance transmission and immunity to electromagnetic interference (EMI), optical FBG sensors embedded tendon was developed to measure strain of 7-wire strand by embedding FBG sensor into the center king cable of 7-wire strand. This FBG sensors embedded tendon has been successfully applied to measuring the short-term anchor force. But to adopt this tendon to long-term monitoring, temperature compensation of the FBG sensors embedded tendon should be done. In this paper, we described how to compensate the effect in compliance with the change of underground temperature during long-term tension force monitoring of ground anchors by using optical fiber sensors (FBG: Fiber Bragg Grating). The model test was carried out to determine the temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon. The determined temperature sensitivity coefficient ${\beta}^{\prime}=2.0{\times}10^{-5}/^{\circ}C$ was verified by comparing the ground temperatures predicted from the proposed sensor using ${\beta}^{\prime}$ with ground temperatures measured from ground thermometer. Finally, temperature compensations were carried out based on ${\beta}^{\prime}$ value and ground temperature measurement from KMA for the tension force monitoring results of tension type and compression type anchors, which had been installed more than 1 year before at the test site. Temperature compensated tension forces are compared with those measured from conventional load cell during the same measuring time. Test results show that determined temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon is valid and proposed temperature compensation method is also appropriate from the fact that the temperature compensated tension forces are not dependent on the change of ground temperature and are consistent with the tension forces measured from the conventional load cell.

Long Term Changes in Sea Surface Temperature Around Habitat Ground of Walleye Pollock (Gadus chalcogrammus) in the East Sea (동해 명태(Gadus chalcogrammus) 서식처 표층수온 장기 변동 특성)

  • Seol, Kangsu;Lee, Chung-Il;Jung, Hae-Kun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.2
    • /
    • pp.195-205
    • /
    • 2020
  • Oceanic conditions in walleye pollock habitat in the East Sea have shown decadal fluctuations between warm and cold periods in turn. Specifically, sea surface temperature (SST) has shown a dramatic increase between the late 1980s and the middle 2000s, and abrupt decreasing patterns after the late 2000s. Oceanic conditions in the Dong-han Bay (spawning ground) and middle eastern coastal waters (fishing ground), however, indicated different fluctuation trends in SST, increasing in the Dong-han Bay after the late 1980s, and decreasing after the late 2000s. These fluctuation patterns were especially clear in February and March. Sea surface temperature in the middle eastern coastal waters of Korea soared continuously after the late 1980s, but did not show a distinct decreasing pattern after the late 2000s compared with Dong han Bay, except for February SST values. These long term water temperature changes in both walleye pollock spawning and fishing ground are related to variation in walleye pollock landings. Especially, abrupt changes in spawning ground SST can be one of the factors influencing survival in the early ontogenesis of walleye pollock, including egg and yolk larval stages. During the 1980s, the area of suitable spawning temperature (2-5℃) was wider, and the length of Walleye pollock egg and larval stages greater compared with past and present oceanographic environments. However, such patterns did not correspond with the optimal spawning temperature range and greater length of development of walleye pollock during the late 1980s likely triggering a decline in pollock stock. In conclusion, it has been supposed that the dramatic decrease in walleye pollock landings in the East Sea since the late 1980s was caused by increasing water temperature leading to both early mortality and unsuitable spawning conditions.

Catch variation of a set net fishing ground in the coastal waters off Neungpo, Goeje Island (거제도 능포 정치망 어장의 어획물과 어획량 변동요인)

  • Cha, Byung-Yul
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.4
    • /
    • pp.211-222
    • /
    • 2009
  • The fisheries resources by a set net in the coastal waters off Neungpo, Goeje Island from 2003 to 2004 were studied to determine species composition and catch variation. The main fishing period by a set net were from April to December in 2003 and from May to December in 2004. A total weight of 48 species caught through the survey period was 540,688.0kg. Most of them were 44 species of fishes and a few were 4 species of cephalopods. Dominant species was Trachurus japonicus accounting to 57.5% in total catch. Sub-dominant species were Trichiurus lepturus(12.9%), Engraulis japonicus(10.6%), Scomber japonicus(6.9%), Clupea pallasii(4.5%), Todarodes pacificus(2.8%) and Parapristipoma trilineaturm(1.3%). The remnant species showed a low catch, indicating the catch had less than 1% in total, respectively. T. japonicus and T. lepturus were caught throughout the survey period, but C. pallasii, Gadus macrocephalus, Oncorhynchus keta in low temperature season and Thunnus obesus in high temperature season. The fishing ground temperature was 11.7-24.0${^{\circ}C}$ in range and the catch by a set net was higher in autumn than in spring and in summer with the variation of fishing ground temperature. The annual catch by a set net was much higher in 2004 than in 2003 due to high temperature(>17${^{\circ}C}$) and the recruitment of T. japonicus from offshore seas. Therefore we concluded that the catch of Neungpo fishing ground by a set net was highly related to the variation of T. japonicus catch with fishing ground temperature.

Application of a Prototype of Microbial Time Temperature Indicator (TTI) to the Prediction of Ground Beef Qualities during Storage

  • Kim, Yeon-Ah;Jung, Seung-Won;Park, Hye-Ri;Chung, Ku-Young;Lee, Seung-Ju
    • Food Science of Animal Resources
    • /
    • v.32 no.4
    • /
    • pp.448-457
    • /
    • 2012
  • The predictive ability for off-flavor development and quality change of ground beef was evaluated using a microbial time temperature indicator (TTI). Quality indices such as off-flavor detection (OFD) time, color, pH, volatile basic nitrogen (VBN), aerobic mesophilic bacteria (AMB) counts, and lactic acid bacteria (LAB) counts were measured during storage at 5, 10, 15, and $25^{\circ}C$, respectively. Arrhenius activation energies (Ea) were estimated for temperature dependence. The Ea values for TTI response (changes in titratable acidity (TA)), VBN, AMB counts, LAB counts, and freshness, which is defined based on OFD time for quality indices of ground beef, were 106.22 kJ/mol, 58.98 kJ/mol, 110.35 kJ/mol, 116.65 kJ/mol, and 92.73 kJ/mol, respectively. The Ea of microbial TTI was found to be closer to those of the AMB counts, LAB counts, and freshness. Therefore, AMB counts, LAB counts, and freshness could be predicted accurately by the microbial TTI response due to their Ea similarity. The microbial TTI exhibited consistent relationships between its TA change and corresponding quality indices, such as AMB counts, LAB counts, and freshness, regardless of storage temperature. Conclusively, the results established that the developed microbial TTI can be used in intelligent packaging technology for representing some selected quality indices of ground beef.

Transient Heat Conduction Through the Ondol Floor and Beat toss to the Ground (온돌의 구들장과 땅바닥의 비정상 열전도 해석)

  • Bae, Soon-Hoon;Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.1
    • /
    • pp.6-17
    • /
    • 1975
  • For a periodic variation of the flue gas temperature the heat conduction through the Ondol floor was analysized. Also the heat loss to the ground was estimated. The floor thermal capacity, as a function of the floor thickness, has strong influence on the time lag of the temperature variation. It is an important design parameter for intermittent heating. Even for the steady periodic variation, there was significant heat loss to the ground below the Ondol floor.

  • PDF

Analysis of Temperature Change of Tunnel Lining with Heating Element (발열체가 적용된 터널 라이닝 내부 및 배면의 온도변화 분석)

  • Jin, Hyunwoo;Kim, Teasik;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.5-12
    • /
    • 2017
  • The damage of the tunnel lining on the cold regions can be represented by cracks and leaks caused by freezing of ground water. However, domestically, the relevant construction guidelines are not provided so far. Thus, in this research, the mechanical behavior and thermal conductivity of designated tunnel area are measured using instrumentation system installed in the lining concrete inside tunnels in order to analysis their behavior with regard to temperature variations. Previous research mainly focused on the effect of temperature on the tunnel lining based on the air and initial ground temperature at urban regions. Thus, this study analyzes effects of air temperature and initial ground temperature of designated tunnel area at the cold regions. The temperature of the groundwater at the backfill of the tunnel lining are analyzed to evaluate the heating element. Numerical analyses are performed to evaluate the heating element with regard to the various initial ground temperatures.

An Applicability Analysis of River Water Source Heat Pump System using EnergyPlus Simulation (에너지플러스 시뮬레이션을 통한 하천수 열원 히트펌프 시스템의 적용 가능성 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.2
    • /
    • pp.10-21
    • /
    • 2022
  • A water source heat pump (WSHP) system is regarded as an energy-efficiency heating and cooling supply system for buildings due to its high energy efficiency and low greenhouse gas emissions. Recently, water sources such as river water, lake water, and raw water are attracting attention as heat sources for a heat pump system in Korea. This paper analyzed the applicability of a river water source heat pump system (RSHP). The river water temperature level was compared with the outdoor air and ground temperature levels to present applicability. In addition, the cooling and heating performance were compared through a simulation approach for the RSHP and a ground source heat pump (GSHP) applied to a large-scale office building. To compare the temperature level, the actual data were applied to the river water and the outdoor air, while the simulation results were applied to the ground circulation water. The results showed that the change in river water temperature throughout the year was similar to the change in outdoor air temperature. However, unlike the outdoor air temperature, the difference between the hourly and daily average river water temperatures was not large. The temperature level of river water was lower during the heating season and somewhat higher during the cooling season than that of the ground circulation water. Finally, the performance of the RSHP system was 13.4% lower than that of the GSHP system on an annual-based.

A Study on the Lunar Ground Temperature Profile for Investigation of Possible Condition of the Ice Layer Existence in Sub-surface of the Moon (달 지하 얼음 층 존재 가능조건 검토를 위한 달 지반 온도 프로파일 산정 연구)

  • Go, Gyu-Hyun;Lee, Jangguen;Shin, Hyu-Soung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.801-809
    • /
    • 2019
  • NASA's lunar polar exploration mission in 2009 confirmed the presence of ice-layer in the permanently shadowed regions (PSR) of the moon. Since then, studies have been actively conducted to evaluate the ground characteristics for exploring the ice-layer in the polar regions of the Moon. In this study, transient heat transfer analysis for the lunar ground was conducted to predict the ground's temperature that varies with the time and location. As a result of the numerical analysis, it was confirmed that the temperature under the lunar ground converged to below the ice sublimation reference temperature (≒112 K) at above 86° latitude. This model enabled us to identify the regions where there is a high possibility of ice being buried. Besides, we found that the ice-layer in the shallow region, where the temperature deviation is significant, makes ground temperature distribution heterogeneous. Lastly, this study suggested the maximum allowable frictional heat of a drill bit that can preserve the phase of buried ice.

Effect of Ground Subsidence on Reliability of Buried Pipelines (지반침하가 매설배관의 건전성에 미치는 영향)

  • 이억섭;김동혁
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.173-180
    • /
    • 2004
  • This paper presents the effect of varying boundary conditions such as ground subsidence, internal pressure and temperature variation for buried pipelines on failure prediction by using a failure probability model. The first order Taylor series expansion of the limit state function incorporating with von-Mises failure criteria is used in order to estimate the probability of failure mainly associated with three cases of ground subsidence. Using stresses on the buried pipelines, we estimate the probability of pipelines with von-Mises failure criterion. The effects of varying random variables such as pipe diameter, internal pressure, temperature, settlement width, load for unit length of pipelines, material yield stress and pipe thickness on the failure probability of the buried pipelines are systematically studied by using a failure probability model for the pipeline crossing ground subsidence regions which have different soil properties.