• Title/Summary/Keyword: Ground rod

Search Result 161, Processing Time 0.023 seconds

Ground ing Impedance Characteristics of Ground Rods in frequency Domain (주파수 영역에서 봉상전극의 접지임피던스 특성)

  • Lee, Hyung-Soo;Shim, Keon-Bo;Kim, Kyung-Chul;Choi, Jong-Kee;Park, Sang-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.248-253
    • /
    • 2005
  • Although DC ground resistance is a good index of grounding performance for grounding electrodes, it does not reflect the grounding performance during transient state. Besides, impulse ground impedance, which is defined by a ratio of the peak value of transient ground potential rise to the peak value of impulse current, cannot be an absolute index due to its dependence on impulse current shape. In this paper, ground impedance of various rod-type ground electrodes has been measured in frequency domain ranging from 1 Hz to hundreds of kHz. Equivalent circuit models of the ground rod have been identified from the measured values of ground impedance in frequency domain.

  • PDF

Measurement Method of the Frequency Dependent Characteristics of Ground Impedance (접지임피던스의 주파수 의존성 측정기법)

  • Eom Ju-Hong;Lee Bok-Hee
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.211-214
    • /
    • 2004
  • The measurement system of ground impedance is based on a computer aided technique. The magnitude and phase of ground impedance were determined by the novel measurement and analysis using the revised fall-of-potential method. The ground impedances of the ground rod of 30 m long are considerably dependent on the frequency. The ground impedance is mainly resistive in the frequency range of 3-20 kHz. At higher frequencies, the reactive components of the ground impedances are no longer negligible and the inductance of the ground rod was found to be the core factor deciding the ground impedance.

  • PDF

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

롯드 체결에 따른 에너지 전달 평가

  • Bae, Myeong-Ho;Yoon, Hyung-Koo;Kim, Ju-Han;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.171-175
    • /
    • 2010
  • Various soil characteristics for safe construction is necessary to understand the tests using the samples collected, and head in place an energy evaluation is conducted to evaluate the ground. In-Situ testing ground, Rod length and around the intrusive when the energy loss due to friction has been measured only in the head. Abstract The purpose of this agreement when increasing contract area of Rod agreement to transform the energy attenuation and the attenuation at the energy being delivered to evaluate. To this end, the same material used in the field test, laboratory test to apply Rod diameter and length have been considered, designed to perform the experiment was to use the Rod. Energy that raised at head of Rod, was increased and decreased by contracting type. The energy difference occurs in the head with the tip that shows the energy rating may be required at the tip is showing. Abstract The energy evaluation for the Rod field test to be at the basic sources and will be able to calculate the trusted information are measured from the tip.

  • PDF

Transient Impedance of the Ground Grid and Deeply-driven Ground Rod (그리드접지와 심매설 접지전극의 과도임피던스)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Jeong, Dong-Cheol;Gil, Hyoung-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.240-243
    • /
    • 2005
  • This paper presents the transient behaviors of grounding system impedance against lighting impulse currents. The dynamic characteristics of the deeply driven ground rod and grounding grid subjected to the impulse current with various rise time were investigated. It was found that the transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient ground impedance of grounding system in the short time domain.

  • PDF

Simulations of Frequency-dependent Impedance of Ground Rods Considering Multi-layered Soil Structures

  • Lee, Bok-Hee;Joe, Jeong-Hyeon;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.531-537
    • /
    • 2009
  • Lightning has a broad frequency spectrum from DC to a few MHz. Consequently, the high frequency performance of grounding systems for protection against lightning should be evaluated, with the distributed parameter circuit model in a uniform soil being used to simulate grounding impedances. This paper proposes a simulation method which applies the distributed parameter circuit model for the frequency-dependent impedance of vertically driven ground rods by considering multi-layered soil structures where ground rods are buried. The Matlab program was used to calculate the frequency-dependent ground impedances for two ground rods of different lengths. As a result, an increase of the length of ground rod is not always followed by a decrease of grounding impedance, at least at a high frequency. The results obtained using the newly proposed simulation method considering multi-layered soil structures are in good agreement with the measured results.

Analysis of the Potential Rises near Grounding Electrodes using Semisplere type scale Model (반구형 축소모델을 이용한 접지전극 주변의 전위상승 분석)

  • Lee, B.H.;Beak, Y.H.;Li, F.;Kim, K.B.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.259-262
    • /
    • 2008
  • This paper describes the ground surface potential profiles near the object to be grounded. The hemisphere water tank was used to simulate the. scale model. As a result, the ground surface potential near the ground electrode was considerably raised. In particular the ground surface potential at the just upper part of ground rod was higher than other part. The ground surface potential was lowered with increasing the buried depth of ground rod.

  • PDF

Transient Ground Impedance of Small-sized Needle-rod Electrodes due to Underground Soil Discharge (토양의 지중방전에 따른 소형 침봉전극의 과도접지임피던스)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.211-215
    • /
    • 2008
  • This paper deals with the transient ground impedance of small-sized needle-rod installed in a test field, Impulse voltage generator was used to inject lightning impulse on a ground electrode and modified fall-of potential method was proposed to measure the high ground potential rise. Transient ground impedance was analysed with impedance curve and I-V curve as respects the resistivity of soil. Soil ionization near the ground electrode is activated in high resistivity soil and have an effect on the reduction of transient ground impedance significantly.

  • PDF

Ground Impedance Characteristics Analysis of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 동봉 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Oh, Jung-Suk;Park, Sang-Young;Choi, Jong-Ki;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.46-51
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. A cower rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of cower rods has been measured in frequency ranging from 60[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Analyses of Hazard Voltages According to the Buried Depth of Small-sized Model Grounding Electrode (축소형 모델 접지전극의 매설깊이에 따른 위험전압의 분석)

  • Paek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.56-61
    • /
    • 2009
  • This paper presents the ground surface potential profiles and hazard voltages around the metallic structure connected to a small-sized model ground electrode. Because it is very difficult to draw valid conclusions concerning a general grounding problem from actual field data, scale model tests can be used to determine the touch and stop voltages and surface potential profiles around ground electrode. In this work, a hemispherical vessel with a diameter of 1,100[mm] was employed to simulate uniform soil. As a result, the ground surface potential around the ground electrode was significantly raised In particular the ground surface potential at the just upper point of ground rod was higher than other points. When the buried depth of ground rod is increased, the ground surface potential and step voltage were lowered but the touch voltage was elevated.