• 제목/요약/키워드: Ground meter

검색결과 163건 처리시간 0.028초

스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구 (An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger)

  • 이상훈;최용석;안근묵
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

A study of in-process optical measurement of surface roughness

  • Noda, Atsuhiko;Harada, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.541-544
    • /
    • 1993
  • This paper attempts to propose new procedures to evaluate roughness of ground metallic surface in the range of 1-10.mu.m from data gained by an optical, in-process measurement of the surfaces. Studies are made to process the data of reflected lights pointed at the surface to be measured. Results obtained are compared with those of measurement by stylus roughness meter. Correlations between the two types of roughness measurement are well. The proposed method can be used as a sensor for a polishing robot.

  • PDF

고장 표정 알고리즘에 적합한 원형 웨이브릿 변환 (Mother Wavelet Transform Suitable to Fault Method Algorism)

  • 박인덕;이승환;김시경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.62_63
    • /
    • 2009
  • This paper is distribution utility to generation of analysis fault several cases on the ground of substation in a energy meter three phase current, voltage data measurement to fault type and characteristics. Mother wavelet transformation of suitable to method algorism from the distribution utility to generation of fault in image impedance etc several parameter for utility characteristics effective to probatory.

  • PDF

소래대교 건설공사 감리 사례 (The Nature of start Businessman and Service Strategy)

  • 전성환
    • 기술사
    • /
    • 제34권2호
    • /
    • pp.42-45
    • /
    • 2001
  • This Grand Sorae Bridge was built in order to lead to balanced reigoonal development by linking the 2nd Seoul - Inchon Highway to WestCiast Highway and it will contribute to develop the economy of the region and traffic of its vicinities by helping ease traffic in and around Inchon. It extends 470 meter across Sorae port by using 10 continuous steel box griders under benoto(all casing) system considering ultra soft ground condition of the site.

  • PDF

단층파쇄대의 사면안정성 연구 (A Study on Slope Stability of Faultzone)

  • 이수곤;금동헌
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.183-190
    • /
    • 2001
  • There are complicated and big shear zone which is about several tens meter in the middle of the cutting slope in this study area. And slope stability analysis is very hard because many fault zones are gathered in the shear zone. This study furnish imformations of scrutinized geological survey, numerical stability analysis, reinforcement work analysis and computation of ground mass properties. Then this offer rational slope stability analysis, rock mass decision and counterplan.

  • PDF

원형 웨이브릿 변환을 이용한 배전계통의 고장점 추출 (Mother Wavelet Transform using Distribution Utility of Fault Point Extraction)

  • 박인덕;이승환;최광진;김시경
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1855-1860
    • /
    • 2009
  • This paper caused a distribution utility to generation of analysis fault several cases on the ground of substation in a energy meter three phase current, voltage data measurement to fault type and characteristics. Mother wavelet transformation of suitable to method algorithm from the distribution utility to generation of fault in image impedance etc several parameter for utility characteristics effective to probatory fault point extraction.

지오텍스타일 보강토벽의 계측결과에 의한 거동분석 (Behavior Analysis from the Site Monitoring Results of Geotextile Reinforced Wall)

  • 원명수;이재열;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.145-152
    • /
    • 1999
  • In the applying of the reinforced soil method, it would be possible to obtain reinforcement effect more than before in terms of economic if high water content clayey soils could be used as embanking material. Futhermore it would be possible to expect the expansion of the applying field of reinforced soil method too. In this study, the authors describe the analysis results on the behavior of 5 meter high walls reinforced with nonwoven geotextile having the permeability and woven geotextile or geogrid having large tensile strength on the soil ground. The behavior of the walls were investigated for about 100 days after construction and the deformations of reinforcements, lateral soil pressures, vertical and horizontal displacements of the walls were examined by automatical measuring system. It was found that this kinds of reinforcing system might effectively improve the performance of the steep walls by virtue of the reciprocal action between soil and reinforcements, and it might be concluded that construction of the clayey reinforced soil walls with three kinds of geotextiles could be done successfully even on the comparative weak ground.

  • PDF

실리카샌드 첨가에 의한 벤토나이트 그라우트의 열전도도 증가 (Thermal Conductivity Enhancement of Bentonite Grout Using Silica Sands)

  • 손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.713-718
    • /
    • 2006
  • This paper concerns the measurement of thermal conductivity of grouting materials for ground loop heat exchanger. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of neat bentonite and mixtures of bentonite and various additives. Relative to the total mixture mass, as the percent additive was increased the mixture thermal conductivity increased. For the bentonite-silica sand mixtures, the higher density of the sand particles resulted in much higher mixture thermal conductivity.

  • PDF

크로스홀 탄성파 시험을 이용한 쇄석다짐말뚝의 시공직경 검측 (Logging for Diametric Variation of Granular Compaction Pile Using Crosshole Seismic Tests)

  • 박철수;정재우;김학성;김은정;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1415-1426
    • /
    • 2008
  • Stone columns, locally called "GCP (granular compaction pile)" can be used to improve strength and resistance against lateral movement of a foundation soil like rigid piles and piers. Also installation of such a discrete column facilitates drainage, and densifies and reinforces the soil in the sense of ground improvement. The integrity of the GCP has been indirectly controlled with the records of each batch including depth and the quantity of stone filled. An integrity testing was attempted using crosshole S-wave logging. The method is conceptionally same as the crosshole sonic logging (CSL) for drilled piers. The only and critical difference is that S-wave should be used in the logging, because P-wave velocity of the stone column is less than that of ground water. The crosshole sonic logger does not have the capability to measure S-wave propagating through the skeleton of crushed stone. An electro-mechanical source, which can generate either P- or SH-waves, and a 1-D geophone were used to measure SH-waves. Two 76mm diameter cased boreholes were installed 1 meter apart across the nominal 700mm diameter stone column. At every 10cm of depth, shear wave was measured across the stone column. One more borehole was also installed 1 meter outward from the one of the above boreholes to measure the shear wave profile of the surrounding soil. The diametric variation of the stone column with respect to depth was evaluated from the shear wave arrival times across the stone column, and shear wave velocities of crushed stone and surrounding soil. The volume calculated with these variational diameters is very close to the actual quantity of the stone filled.

  • PDF

다양한 실험조건을 고려한 동결 사질토의 열전도도 산정에 대한 연구 (Study on the Thermal Conductivity of Frozen Soil Considering Various Experimental Conditions)

  • 김희원;고규현
    • 한국지반공학회논문집
    • /
    • 제39권9호
    • /
    • pp.5-11
    • /
    • 2023
  • 지반구조물의 해석에 있어서 해석의 고려 대상과 분야가 점점 다변화되고 있으며, 특히 지반동결과 관련된 분야에서 지반재료의 열적거동 특성에 대한 예측의 필요성이 중요해지고 있다. 신뢰성 있는 지반의 동결거동 평가를 위해서는 다양한 조건에서의 시료의 유효 열전도도 변화에 대한 고려가 필요하다. 본 논문에서는 시료의 간극률, 초기 포화도, Read time 설정을 달리하여 탐침 실험을 수행하였고, 이를 통해 동결 사질토의 유효 열전도도에 영향을 미치는 인자들을 평가하였다. 서로 다른 간극률 조건에서 실험을 수행한 결과, 시료의 간극률이 작을수록 동결토의 유효 열전도도는 증가하는 경향이 나타났다. 반면, 시료의 포화도가 증가할수록 동결토의 유효 열전도도는 증가하였다. 유효 열전도도 측정에 대한 계측기 Read time 설정의 민감도가 존재하였는데, Read time을 1분으로 설정하여 측정하였을 때 측정값의 범위가 국내의 선행연구결과와 유사하게 나타났다.