• Title/Summary/Keyword: Ground densification

Search Result 15, Processing Time 0.019 seconds

Evaluation Technique of Ground Densification on Sand Deposit using SASW and Resonant Column Tests (표면파시험과 공진주시험을 이용한 사질토지반 개량평가 시스템의 개발)

  • 김동수;박형춘;김성인
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 1999
  • In order to assess the quality and depth of ground densification by compaction, SPT and/or CPT are performed before and after compaction. Both methods are intrusive and one point tests, require a substantial time to evaluate a large area, and their results are quite dependent on the operation technique and soil type. In this paper, the quality and extent of ground densification by compaction was evaluated by using in situ SASW test and laboratory resonant column (RC) test results. SASW test was used to determine the shear wave velocity profiles before and after compaction, and RC test was adopted to determine the correlation between the normalized shear wave velocity and the density of the site, which is almost uniquely independent of confinement. Testing and data reduction procedures of both tests were discussed, and a simplified evaluation procedure of ground densification was proposed. Finally, the feasibility of the proposed method was verified by performing field study at Inchon International Airport Project. Field densities determined by the proposed method matched well with those determined by sand cone tests.

  • PDF

Evaluation of Ground Improvement on Sands at Yongjong Island Geotechnical Experimental Site (영종도 지반공학 야외시험장에서의 사질토지반 개량효과 평가)

  • 김동수;박형춘;김영웅;김수일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.439-446
    • /
    • 1999
  • In situ experimental studies were Performed at Yongjong Island Geotechnical Experimental Site to evaluate the ground densification on sand deposited. Standard penetration test, cone penetration test, and SASW test were performed and soil profiles and quality of ground improvements were evaluated. The feasibility of applying SASW method were verified by comparing test results. The evaluation technique of in-situ density using SASW and resonant column tests was proposed, and the reliability of proposed method was verified by performing case studies.

  • PDF

A FEM Alalysis to the Sand Densification due to Increasing Loading (점증하중을 받는 사질토 지반의 조밀화에 대한 유한요소해석)

  • 한경제
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.79-85
    • /
    • 2000
  • 본 논문에서는 사질토 지반에 일정기간 계속하여 증가되는 단계별 하중이 작용할 때 발생할수 있는 지반의 밀도화 현상을 hyperbolic model의 매개변수 변화를 고려한 방법으로 유한요소법에 의한 수치적 침하해석에 반영해 주었다. 이를 위해 사질토의 상대밀도별 삼축압축실험을 실시하여 매개변수를 산정하였으며, 이를 토대로 각각의 상대밀도의 변화에 따른 매개변수값을 Lagrange의 다항식 수치보간법으로 프로그램에 반영하였다. 또한 유한요소프로그램 내에서 요소의 체적을 계산하고 체적의 변화를 상대밀도 개념으로 접근함으로서 지반의 밀도화를 프로그램내에서 모사할수 있도록 하였다. 본 연구에서 개발한 해석 프로그램에 의한 지반의 밀도화현상의 모사 결과를 실내 모형기초재하실험에 의하여 비교 분석해 본 결과 기존의 해석 보다 향상된 결과를 나타냄을 알 수 있었다.

  • PDF

A Study on the Ground Improvement by Compaction Grouting System (C.G.S에 의한 기초지반보강효과에 관한 연구)

  • 천병식;여유현;최현석;오일석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.02a
    • /
    • pp.1-13
    • /
    • 1999
  • The use of Compaction Grouting evolved in the 1950's to correct structural settlement of buildings. Over the almost 50 years, the technology has developed and is currently used in wide range of applications. Compaction Grouting, the injection of a very stiff, 'zero-slump' mortar grout under relatively high pressure, displaces and compacts soils. It can effectively repair natural or man-made soil strength deficiencies in variety of soil formations. Major uses of Compaction Grouting include densifying loose soils or fill voids caused by sinkholes, poorly compacted fills, broken utilities, improper dewatering, or soft ground tunneling excavation. Other application include preventing liquefaction, re-leveling settled structures, and using compaction grout bulbs as structural elements of minipiles or underpinning. The technique replaced slurry injection, or 'pressure grouting', as the preferred method of densification grouting. There are several reasons for the increased use of Compaction Grouting which can be summarized in one word: CONTROL. The low slump grout and injection processes are usually designed to keep the grout in a homogeneous mass at the point of injection, while acceptable in some limited applications, tends to quickly get out of control. Hydraulic soil fracturing can cause extensive grout travel, often well beyond the desired treatment zone. So, on the basis of the two case history constructed in recent year, a study has been peformed to analyze the basic mechanism of the Compaction Grouting and verify the effectiveness of the ground improvement using some test methods.

  • PDF

A Study on the Ground Improvement by Compaction Grouting System (CGS에 의한 기초지반보강에 관한 연구)

  • 천병식;권형석
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.4
    • /
    • pp.9-19
    • /
    • 1999
  • The use of compaction grouting evolved in 1950's to correct structural settlement of buildings. Over the almost 50 years, the technology has been developed and is currently used in wide range of applications. Compaction grouting, the injection of a very stiff, 'zero-slump' mortar grout under relatively high pressure, displaces and compacts soils. It can effectively repair natural or man-made soil strength deficiencies in variety of soil formations. Major applications of compaction grouting include densifying loose soils or fill voids caused by sinkholes, poorly compacted fills, broken utilities, improper dewatering, or soft ground tunneling excavation. Other applications include preventing liquefaction, re-leveling settled structures, and using compaction grout bulbs as structural elements of minipiles or underpinning. In this paper, on the basis of the case history constructed in this year, a study has been performed to analyze the basic mechanism of the compaction grouting. Also, the effectiveness of the ground improvement and the bearing capacity of the compaction pile has been verified by the Cone Penetration Test(CPT) and Load Test. Relatively uniform compaction grouting column could be maintained by planning the quality control in the course of grouting. And, the Qualify Control Plan has been conceived using grout pressure, volume of grout and drilling depth.

  • PDF

Reinforcement of the Foundation using C,G.S (C.G.S공법에 의한 기초지반 보강)

  • 천병식;권형석;정의원
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.441-448
    • /
    • 2000
  • While the Grouting has been used to reinforce the foundation of structures in wide range of application, there need complementary measures against problems such as pollution, durability, influence on the adjacent structures. Compaction Grouting, the injection of a very stiff, 'zero-slump' mortar grout under relatively high pressure, displaces and compacts soils. It can effectively repair natural or man-made soil strength deficiencies in variety of soil formations. In this paper, on the basis of the case history constructed in this year, a study has been performed to analyze the basic mechanism of the Compaction Grouting, Also, the effectiveness of the ground improvement and the bearing capacity of the Compaction Pile has been verified by the S.P.T and core strength.

  • PDF

The Impact of Supertall Density on City Systems

  • Price, Bill;Bickerdyke, Andrew;Borchers, Meike;Gabbitas, Tim;Hailey, Lee
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.4
    • /
    • pp.327-332
    • /
    • 2017
  • This paper discusses several topics associated with the densification caused by supertall buildings and their impact on city systems. The paper covers five key areas where a supertall tower creates a concentration of needs and effects. First, the paper comments on population shifts towards the city and how they affect carbon footprint, utilities infrastructure and transport. The effect of single- and mixed-use towers is discussed in the context of population density. The second section brings the issues of transit, accessibility and master planning into focus. The use and criticality of public transport, cycling and walking is described. Servicing and deliveries using freight consolidation and shared systems is also discussed along with their contribution to the culture of sustainable travel. In the third section the paper reflects on supertall buildings' below-ground utilities and drainage provision, particularly the challenges faced in established city infrastructures. The utilities issues associated with supertall concentration (in land-use terms) compared to equivalent low-rise distribution is also commented on in the context of surface water runoff. In the fourth section, the topic of supertall sustainability is discussed and how city systems need to respond to create desirable and affordable space for occupiers. The changing need for vertical communities, 'stacked neighbourhoods' and the notion of a micro-city is described. Finally, the paper considers the energy consumption and resilience of supertall buildings in the context of basic geometry, façade design, climate and mixed-use benefits as they impact city systems.

A Study on the Behavior of George Massey Immersed Tunnel during Earthquake (지진 시 George Massey 침매터널의 거동에 관한 연구)

  • Park, Sung-Sik;Moon, Hong-Duk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.221-230
    • /
    • 2008
  • The George Massey immersed tunnel passes the Fraser River near Vancouver, Western Canada. The tunnel was founded on sandy soils and its behavior during earthquake was analyzed by an effective stress constitutive model called UBCSAND. This model is able to calculate pore pressure rise and resulting tunnel movements due to cyclic loading. Centrifuge tests conducted at Rensselaer Polytechnic Institute (RPI) were used to verify the model performance. The centrifuge tests consisted of 2 models: Model 1 was designed for an original ground condition, Model 2 for a ground improvement by densification. In Model 1, large deformation of the tunnel was observed due to liquefaction of surrounding soil. Because of the densified zones around the tunnel the vertical and horizontal displacements of the tunnel in Model 2 was 50% less than Model 1. Measured excess pore pressures, accelerations, and displacements from centrifuge tests were in close agreement with the predictions of UBCSAND model. Therefore, the model can be used to predict seismic behavior of immersed tunnels on sandy soils and optimize liquefaction remediation methods.

Numerical analysis of offshore monopile during repetitive lateral loading

  • Chong, Song-Hun;Shin, Ho-Sung;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.19 no.1
    • /
    • pp.79-91
    • /
    • 2019
  • Renewed interest in the long-term pile foundations has been driven by the increase in offshore wind turbine installation to generate renewable energy. A monopile subjected to repetitive loads experiences an evolution of displacements, pile rotation, and stress redistribution along the embedded portion of the pile. However, it is not fully understood how the embedded pile interacts with the surrounding soil elements based on different pile geometries. This study investigates the long-term soil response around offshore monopiles using finite element method. The semi-empirical numerical approach is adopted to account for the fundamental features of volumetric strain (terminal void ratio) and shear strain (shakedown and ratcheting), the strain accumulation rate, and stress obliquity. The model is tested with different strain boundary conditions and stress obliquity by relaxing four model parameters. The parametric study includes pile diameter, embedded length, and moment arm distance from the surface. Numerical results indicate that different pile geometries produce a distinct evolution of lateral displacement and stress. In particular, the repetitive lateral load increases the global lateral load resistance. Further analysis provides insight into the propagation of the shear localization from the pile tip to the ground surface.

Temperature-compensated Resistivity Probe - Development and Application (온도보상형 전기비저항 프로브 - 개발 및 적용)

  • Jung, Soon-Hyuck;Yoon, Hyung-Koo;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Electrical resistivity is applied for understanding details about layers and obtaining basic properties of soils to various measurement devices. The objective of this study is development of TRP(Temperature-compensated Resistivity Probe), analysis about effects of temperature changes during cone penetration test, and observation of characteristics of cone penetration. In order to observation of temperature changes according to a diameter difference of resistivity cone probe, the cone which has wedge type cone tip is made to two types, 2mm and 5mm. Temperature sensor is attached at 15mm below from cone tip because of an electrical interference with elecrical resistance probe. Delectrical connector is used to prevent electric disturbance between motor type penetrating machine and electrical resistivity cone probe. Application tests are carried out in acrylic cell whose diameter is 30cm with uniform Jumunjin sand according to densification caused by blows. The test results indicate that the temperature is increased uniformly during penetration and a tendency, characteristics of cone penetration, is discovered during altering state of soils. This study suggests that the temperature effects and characteristics of penetration should be considered in penetrating tests in order to conduct an accurate ground investigation using TRP(Temperature-compensated Resistivity Probe).