• Title/Summary/Keyword: Ground current

Search Result 1,725, Processing Time 0.025 seconds

Antenna Factors of Half-wave Resonance Dipole Antennas above the Ground Plane (접지판 위에 놓여진 반파장 공진다이폴 안테나의 안테나 인자)

  • Ki-Chai Kim
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.3-9
    • /
    • 1991
  • This paper presents the characteristics of antenna factors of half-wave resonance dipole antennas above a ground plane. The current distributions on a horizontal and vertical dipole antennas were analyzed by the Galerkin's method of moments, and these solutions are used for calculating the horizontal and vertical antenna factors above the ground plane. It is shown that accurate antenna factors of the horizontal and vertical dipole above the ground plane are required of the radiated emission test.

  • PDF

The study on the ground wire size (접지선 굵기에 관한 연구)

  • 최홍규;최병숙;송영주
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.97-102
    • /
    • 2003
  • Ground in must choose enough sectional area of conductor endurably in maximum fault current, fault duration time, maximum allowable temperature and have strong durability and life-time can bear enough from spontaneous corrosion or electrolytic corrosion and must choose material that problem does not exist electrically and mechanically when connection or junction. In this paper, modeled new ground wire size numerical formula, and examine and compare of modeled numerical formula and abroad regulation, and proved and analyzed validity of the new ground wire size computation method because do simulation to computer program.

  • PDF

A Fundamental Study on the Impulse Responses of Ground Rod Attendant upon Soil Discharges (토중방전을 수반하는 접지봉의 임펄스응답에 대한 기초적 연구)

  • Yoo, Yang-Woo;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.62-69
    • /
    • 2014
  • This paper deals with the fundamental characteristics of transient and conventional ground impedances associated with soil discharges when the lightning impulse voltage was applied to a small-sized ground rod. The potential rise responses of the test ground rod to impulse currents were observed. The current-voltage (I-V)curves, transient and conventional ground impedance curves were examined.. To analyze the transient behaviors of ground rod attendant upon soil discharges, the impulse responses of ground rod were compared with those of non-inductive resistor. As a consequence, the potential rise and impedance of ground rod were reduced and the currents dispersed into the earth were increased due to soil discharges near the ground rod. Soil discharges are classified into two regimes; ionization and breakdown phenomena. The potential rise and impulse impedance of ground rod are significantly decreased by breakdown processes in soil.

Effects of Auxiliary Probe on Low Frequency Ground Impedance Measurement (저주파 접지임피던스 측정에 미치는 보조전극의 영향)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Moon, Hyun-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.367-370
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the auxiliary probes on the measurements of the low frequency ground impedance with the fall-of-potential method are described iud the testing techniques to minimize the measuring errors are proposed. The fall-of-pot ential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the characteristics of ground impedance due to the location of the potential probe, ground impedances were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from 10[m] to 50[m]. Also, the potential robe was located at 30[$^{\circ}$], 40[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$], and 180[$^{\circ}$]. The results could be help to determine the location of potential probe when the ground impedance was measured at grounding system.

  • PDF

An Analysis of Potential Interference in the Vicinity of the Vertical Ground Rod (수직 접지전극 주변에서 전위간섭의 분석)

  • Lee, Bok-Hee;Lee, Kang-Soo;Seong, Chang-Hoon;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.85-91
    • /
    • 2011
  • A grounding system is generally composed of several vertical, horizontal electrodes or grids. Excessive ground potential rises due to adjacent grounding electrodes can cause failures or misoperation of electronic devices and control systems. It is therefore necessary for computer-related and information-oriented equipment to be placed at a sufficient distance from the areas influenced by grounding electrodes. In this paper, in order to propose a method for evaluating the ground potential rise and interference in the vicinity of vertical grounding electrodes, the experimental and theoretical results on the potential interference between vertical grounding electrodes and its frequency dependence were described. The ground potential rise is sharply decreased with increasing the distance between grounding electrodes. In case that the separation of vertical grounding electrodes is less than 1.5[m], the potential interference coefficient was greater than 0.1 and linearly increased with the frequency of the test current within the frequency of 1[MHz].

CLIMATOLOGICAL CHARACTERISTICS OF THE POLAR IONOSPHERE BASED ON THE SONDRESTROM INCOHERENT SCATTER RADAR MEASUREMENTS (SONDRESTROM 비간섭 산란 레이더 자료를 이용한 극지방 전리층의 기후학적 특성 연구)

  • 곽영실;안병호
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.1
    • /
    • pp.75-88
    • /
    • 2002
  • The climatological characteristics of the polar ionosphere is examined in terms of the ionospheric conductance and electric field. For this purpose, 109 days of measurements from the Sondrestrom incoherent scatter radar are utilized. By combining these two quantities, it is possible to deduce the overhead ionospheric current distributions. The ionospheric current density thus obtained is compared with the corresponding ground magnetic disturbance. Also examined is the effect of the field-aligned current on the ground magnetic disturbance, particularly on the D component Several interesting climatological characteristics about the ionosphere over the Sonderstrom are apparent from this study. (1) The conductance distribution is mainly due to solar EUV radiation during day-time On the other hand, the conductance distribution during the night-time is very low. (2) The conductance distribution one. the polar cap region during the day-time is controlled mostly by the solar EUV radiation, while it is extremely low during night-time wish the Hall and Pedersen conductances being 1.6 and 1.2 siemen, respectively (3) The region of the maximum N-S electric field tend to locate in the dayside sector. The E-W component of the electric field is stronger than that over Chatanika (4) The E-W auroal inospheric current (J/sub E/) is more important in the sunlit hemisphere than the night hemisphere. And a strong southward current is noted in the prenoon sector (5) There is a significant correlation between the overhead ionospheric current and the simultaneously observed ground magnetic disturbance. However, the assumption for the infinite sheet current approximation is far from realistic, underestimating the current density. And the correlation between ${\Delta}H$ and J/sub E/ is higher than the one between ${\Delta}D$ and J/sub N/ , indicating that field-aligned current affects significantly ${\Delta}D$.

Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter (저항접지 시스템에서 지락사고시 CLR과열 소손방지를 위한 GPT 정격용량의 적정성 연구)

  • Shin, Ho-Jeon;Kim, Jin-Seok;Park, Yu-Hwan;Kim, Jae-Chul;Cho, Man-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.503-508
    • /
    • 2012
  • Among the high distribution voltage consumers, high-capacity consumers are often applying the grounding resistance method in order to overcome demerits such as erroneous operation of the ground reply or potential increase in the battery at the accident of the isolated neutral system. In this paper, to prevent damage to CLR and GPT in the delay to block the breakdown in the resistance grounded neutral system, this study aims to provide a proper suggestion for continuous rating capacity of GPT to check the appropriateness of CLR size and reduce GPT burden. Thereupon, this study comparatively analyzes CLR current applied in general GPT and the current gained when CLR demanded in the system is used and analyzes the simulated system through simulation using PSCAD/EMTDC in order to suggest GPT's proper continuous rating capacity.

A 3.3V-65MHz 12BIT CMOS current-mode digital to analog converter (3.3V-65MHz 12비트 CMOS 전류구동 D/A 변환기 설계)

  • 류기홍;윤광섭
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.518-521
    • /
    • 1998
  • This paper describes a 3.3V-65MHz 12BIT CMOS current-mode DAC designed with a 8 MSB current matirx stage and a 4 LSB binary weighting stage. The linearity errors caused by a voltage drop of the ground line and a threshold voltage mismatch of transistors have been reduced by the symmetrical routing method with ground line and the tree structure bias circuit, respectively. In order to realize a low glitch energy, a cascode current switch ahs been employed. The simulation results of the designed DAC show a coversion rate of 65MHz, a powr dissipation of 71.7mW, a DNL of .+-.0.2LSB and an INL of .+-.0.8LSB with a single powr supply of 3.3V for a CMOS 0.6.mu.m n-well technology.

  • PDF

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI) (ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구)

  • Park Jae Hong;Lee Jong Beom
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

A Low Power SDRAM Output Buffer with Minimized Power Line Noise and Feedthrough Current (최소화된 Power line noise와 Feedthrough current를 갖는 저 전력 SDRAM Output Buffer)

  • Ryu, Jae-Hui
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.8
    • /
    • pp.42-45
    • /
    • 2002
  • A low power SDRAM output buffer with reduced power line noise and feedthrough current is presented. In multi I/O SDRAM output buffer, feedthrough current as well as the corresponding power dissipation are reduced utilizing proposed undershoot protection circuits. Ground bounce is minimized by the pull down driver using intelligent feedback scheme. Ground bounce noise is reduced by 66.3% and instantaneous and average power are reduced by 27.5% and 11.4%, respectively.