• 제목/요약/키워드: Ground Water

검색결과 3,602건 처리시간 0.035초

강변여과수 열원 히트펌프 온실난방 성능시험 (Estimation of Greenhouse Heating performance for Ground Filtration Water Source Heat Pump)

  • 문종필;이성현;권진경;강연구;이수장
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.200.2-200.2
    • /
    • 2011
  • This study was carried out in order to estimate the greenhouse performance for Ground filtration water source heat pump which was installed for supplying the heat to the paprika greenhouse in Jinju city. Experimental area of Greenhouse was $3,300m^2$, For keeping the heat from greenhouse, single plastic covering and double thermal screen was installed. With considering all of greenhouse insulation condition and designed heatng temperature, heating capacity for experimental greenhouse was calculated as 320,000kcal/hr. Coefficient of performance(COP) of Ground filtration water source heat pump was gauged and greenhouse heating performance was tested from Febuary 1 to Febuary 28 in 2011. The result showed that COP of heat pump was in the range of 3.7~4.7 and COP of heating system was in the range of 3.0~3.5. The vaule of COP was very high and the temperature inside greenhouse was well corresponded to the setting temperature of greenhouse environment controlling system. lots of Ground filtration water made the the number of well fewer and the expense for installing heating system cheaper than that of geothermal system used custmarily. and this system went beyond the limitation of intaking amount of groundwater in normal Groundwater source heat pump.

  • PDF

신재생에너지를 이용한 사막화 방지 시스템 실증 (몽골) (Demonstration of system to combat desertification using renewable energy)

  • 김만일;이승훈;황정훈;조운식;박문희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 2009
  • Generally, wind or solar power system is operated as a stand-alone power system, the efficiency of which could be higher by designing wind-solar combined system considering average wind speed and solar radiation of the desert region, Mongolia. This system is designed to generate electricity for power users and pumps the ground water for irrigation using deep well pump. The ground water can be used for farming or forestation where there is no or little irrigation system. In connection with this study, a renewable energy park, Green Eco Energy Park, was developed at about 50km east of Ulaanbaatar. 3 sets of 10kW wind power generator and 70 kW of solar power module were installed there. The electricity generated from the system is used to on-site office building and deep well pump for ground water pumping. A 10kW stand-alone solar pumping system, which has no rechargeable battery system, is installed to pump the ground water with the amount of generated power. The ground water is stored in 3 artificial ponds and then it is used for raising nursery tree and farming. The purpose of this study is to provide a possible energy solution to desert regions where there is no or little power system. The system also supply power to ground water pump, and the water can be used for farming and forestation, which will also be a solution of preventing desertification or spreading of desert area.

  • PDF

뉴질랜드 캔터배리 지역 연속지진에 의해 발생된 일시지반변형과 매설된 상수도관 성능평가 (Transient Ground Deformation induced by Sequential Earthquakes and Estimation of Underground Water Pipeline Performance in Canterbury, New Zealand)

  • 전상수
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2818-2827
    • /
    • 2015
  • 본 연구는 최근 뉴질랜드 Canterbury 지역에서 연속적으로 일어난 지진의 지진계 기록과 지리정보체계(GIS)의 정규크리깅을 이용하여 최대지반속도(PGV)와 기하평균최대지반속도(GMPGV) 컨투어를 생성하였고 이들의 공간적 패턴과 특징을 조사하였다. 지진발생 후 얻어진 데이터를 이용하여 지하의 상수도관 시스템의 성능에 주안점을 두고 연구를 수행하였다. 기하평균최대지반속도의 공간분포와 일시적인 지반거동으로 인하여 발생된 상수도관 시스템의 GIS 중첩과 비액상화지역의 기하최대지반속도와의 관계를 통하여 서로 다른 재질의 상수도관에 따른 1 km 당 매설된 상수도관 손상 개수로 산정되는 손상율을 산정하였다. 또한, 본 연구는 매설된 상수도관의 지진성능을 요약하여 설명하였다.

수리역학 연계해석을 이용한 누수로 인한 터널 구조물 및 지반 거동의 분석 (Investigation on Water Leakage-Induced Tunnel Structure and Ground Responses Using Coupled Hydro-Mechanical Analysis)

  • 박도현
    • 터널과지하공간
    • /
    • 제33권4호
    • /
    • pp.265-280
    • /
    • 2023
  • 터널누수는 주변지반의 응력 및 간극수압을 변화시켜 터널 안정성 및 지반변형에 영향을 미칠 수 있는 결함요소이다. 장기간 또는 큰 규모의 누수발생은 터널 라이닝의 불안정성 및 지표침하와 같은 터널 구조물 및 주변지반 환경에 손상을 일으킬 수 있다. 본 연구에서는 누수발생 시 터널의 구조 안정성 및 지반거동에 미치는 영향을 수치해석적으로 분석하였다. 고려된 터널은 내부로 주변 지하수의 유입을 허용하지 않는 비배수 조건으로 가정하였고 터널 완공 후 라이닝에서 누수가 발생하는 것으로 설정하였다. 누수로 인한 터널 구조물 및 지반의 거동을 모사하기 위해 수리역학 연계해석이 수행되었으며 파이썬으로 개발된 TOUGH-FLAC 시뮬레이터가 사용되었다. 누수 발생량과 누수위치를 변화시켜 수치모사가 수행되었으며 수리역학 해석을 위한 연계항들이 복합거동 결과에 미치는 영향을 조사하였다.

지중열전도도 측정과 지중열교환기의 열확산 특성 분석 (Measurement of Ground Thermal Conductivity and Characteristics of Thermal Diffusion by the Ground Heat Exchanger)

  • 정영만;구경민;황유진;장세용;이영호;이동혁;이재근
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.739-745
    • /
    • 2008
  • This paper presents the measurement of ground thermal conductivity and the characteristics of ground thermal diffusion by a ground heat exchanger(GHE). A borehole is installed to a depth of 175 m with a diameter of 150 mm. To analyze the thermal diffusion property of the GHE, thermocouples are installed under the ground near the GHE. The outdoor temperature, the ground temperature, and the water temperature of the GHE are monitored for evaluating the characteristics of ground thermal diffusion. The ground thermal conductivity is evaluated by the in-situ thermal response tester and the line source model. It is found to be 3.08 W/$m^{\circ}C$ in this study. The ground temperature is greatly dependent on the outdoor temperature from the ground surface to 2.5 m in depth and is stable below 10 m in depth. The surface temperature of the GHE varies as a function of the temperature of circulating water. But the ground temperature at 1.5 m far from the GHE is not changed in accordance with the temperature of circulating water.

USGS 지하수 연구정책 소개 (USGS Groundwater Scientific Research Policy)

  • 염병우
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제12권6호
    • /
    • pp.8-13
    • /
    • 2007
  • 이 현장보고에서는 앞으로 10년간 수행될 USGS 연구정책의 방향과 USGS 수자원국의 지하수 분야의 테마, 생물국의 전략, 그리고 지하수 연구자들의 모델링 분야 보고서 표준화 노력에 대하여 다운사이징의 방법으로 소개하였다. USGS는 생태계와 생태계 변화에 중점을 둔 연구를 최우선 주제로 제시하였으며, 지하수 분야는 특히 이 정책 주제의 중심에 있다고 할 수 있다. 이 소개를 통하여 우리 연구자들의 현재를 돌아보고 앞으로의 계획에 도움을 줄 수 있기를 기대 하는 바이다.

국가 지하수 정보 종합관리 체계의 구축과 활용(II) - 두레박 프로그램과 지하수세상 홈페이지 -

  • 손영철;김규범;최영진
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.270-274
    • /
    • 2000
  • We have developed the computer system with MOCT which is called "The Integrated National Groundwater Information system" since 1995 and now begin to supply the database and related informations for ground water by internet homepage. The integrated system is composed of four sub systems which are "Groundwater Information System", "DUREBAK", "Hydrogeologic Map Management System" and "Groundwater World Homepage". The local government offices use the "DUREBAK" program to manage the well development and maintenance. About 1,000,000 wells are managed in "DUREBAK" program and they submit the well database to MOCT every year. And now everyone can obtain the well data and other informations through internet homepage. We have set the standard process of data acquisition and management for ground water last four years.s of data acquisition and management for ground water last four years.

  • PDF

현장계측에 의한 지반거동 분석 (Ground Movement Analysis by Field Measurements)

  • 전용백;조상완
    • 한국산업융합학회 논문집
    • /
    • 제8권3호
    • /
    • pp.161-168
    • /
    • 2005
  • This study is analysis for adjacent structures and ground movement by deep excavation work. Underground Inclinometer has shown that deformation of increment is minor within to allowable limit. According to the measurements result of slope and crack for adjacent structures, a detached house showed bigger than hospital structure to deformation of increment. Variation of underground water level didn't effect so much to ground and adjacent structures movement because underground water flows in rock and didn't give the water press to propped walls. Measurement data of strut variation is within tolerance limit. Because excavation site's wall was strengthened suitably. This study will contribute in establishment of measurement standard and information-oriented construction during deep excavation in multi-layered ground including rock masses.

  • PDF

Determination of Icing Inhibitors (Ethylene Glycol Monomethyl Ether and Diethylene Glycol Monomethyl Ether) in Ground Water by Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang;Jung, Dong-Gyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.806-808
    • /
    • 2004
  • A gas chromatography/mass spectrometric assay method has been developed for the simultaneous determination of icing inhibitors, ethylene glycol monomethyl ether and diethylene glycol monomethyl ether in ground water contaminated with JP-8. Ethylene glycol monobutyl ether and ethylene glycol monoethyl ether were used as the internal standard and surrogate, respectively. 100 mL of ground water was extracted twice with 20 mL of methylene chloride. The extract was concentrated to dryness, dissolved with 100 ${\mu}$L of methanol and analyzed by GC-MS (SIM). The use of an Innowax column gave the peaks good chromatographic properties, and the extraction of these compounds from samples gave recoveries of about 50% with small variations. The method detection limits of the target compounds were in a range of 0.5-0.8 ng/mL in ground water.

철도 터널 공사시 지하수 발생량 산정에 관한 연구 (Evaluation of Groundwater Flow on Railroad Tunnel Excavation)

  • 어성욱;안태봉;최승선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.448-453
    • /
    • 2005
  • Tunnel excavation is an inevitable process for railroad construction in Korea and it being a one of the major issues of its environmental impact assessment. Ground water flow by tunnel excavation is an important parameter to determine environmental effects. The current method to determine the ground water flow is used a unit number induced a highway construction site. But it does not consider any site characteristics; ground water level, soil properties and others. The purpose of this study is to suggest the determination way of ground water flow considering site characteristics in tunnel construction.

  • PDF