• Title/Summary/Keyword: Ground Plate

Search Result 444, Processing Time 0.034 seconds

Relationship between Dimensionless Leg Stiffness and Kinetic Variables during Gait Performance, and its Modulation with Body Weight

  • Hyun, Seung Hyun;Ryew, Che Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.249-255
    • /
    • 2016
  • Objective: This purpose of this study was to analyze the relationship between dimensionless leg stiffness and kinetic variables during gait performance, and its modulation with body weight. Method: The study sample consisted of 10 young women divided into 2 groups (Control, n=5 and Obese, n=5). Four camcorders (HDR-HC7/HDV 1080i, Sony Corp, Japan) and one force plate (AMTI., USA) were used to analyze the vertical ground reaction force (GRF) variables, center of pressure (COP), low limb joint angle, position of pelvis center and leg lengths during the stance phase of the gait cycle. Results: Our results revealed that the center of mass (COM) displacement velocity along the y-axis was significantly higher in the obese group than that in control subjects. Displacement in the position of the center of the pelvis center (Z-axis) was also significantly higher in the obese group than that in control subjects. In addition, the peak vertical force (PVF) and dimensionless leg stiffness were also significantly higher in the obese group. However, when normalized to the body weight, the PVF did not show a significant between-group difference. When normalized to the leg length, the PVF and stiffness were both lower in the obese group than in control subjects. Conclusion: In the context of performance, we concluded that increased dimensionless leg stiffness during the gait cycle is associated with increased velocity of COM, PVF, and the change in leg lengths (%).

Identification of Cylindrocarpon destructans Associated with Root Rot Disease of Strawberry (딸기 뿌리썩음병(病)에 관여하는 Cylindrocarpon destructans의 분리(分離) 동정(同定))

  • Sung, Jae-Mo;Song, Yoong-Nam;Yang, Sung-Suk
    • The Korean Journal of Mycology
    • /
    • v.13 no.3
    • /
    • pp.179-183
    • /
    • 1985
  • Cylindrocarpon spp. were isolated from the soil where strawberry was grown in Suweon by soil plate method: colonies reaching 10 mm diam. in seven days at about $20^{\circ}C$; sporodochia with cream to beige to conidial slime commonly produced; conidiophore repeatedly branched and bearing subulate phialides; macroconidia cylindrical in the center part, straight or slightly curved and mostly $1{\sim}3\;septate,\;22{\sim}45\;{\times}\;5.0{\sim}6.0\;{\mu}m$; chlamydospore abundantly produced, intercalary or terminal on mycelium, singly or in chains and smooth or warted. The hypha and spore were easily fused each other on water agar. This fungus was pathogenic strawberry as a result of inoculation test. The symptom showed dwarf and yellowing at top and rotted roots under the ground. The fungus was identified as Cylindrocarpon destructans Scholten from the shape of conidiophores and conidia, mycelial growth and pathogenicity test.

  • PDF

Development of an Intelligent Compaction Evaluation Method Based on Statistics Analysis (통계해석에 기초한 연속다짐평가기법 개발)

  • Park, Keun-Bo;Kim, Ju-Hyong
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.8
    • /
    • pp.5-16
    • /
    • 2011
  • The objective of this paper is to assess the potential use of the resilient force of the ground obtained from an accelerometer and to propose a new compaction control process. Several comprehensive field experimental programs were conducted to analyze the correlation of compaction results obtained from an accelerometer and conventional test methods (e.g. the plate load test and field density test). This study focused on comparing the compaction results obtained from an accelerometer with conventional test results statistically. Based on the statistical analysis results, impact and resilient force measured from an accelerometer, mounted on the drum of a roller are very useful factors for continuous compaction control. A new compaction criteria determination process using an accelerometer is also proposed in this study.

Non-Contacting Capacitive Sensor with 4-Electrodes for Measuring Small Displacement (미소변위 측정용 비접촉식 4-전극형 전기용량 센서)

  • Lee, Rae-Duk;Kim, Han-Jun;Park, Se-Il;Semyonov, Yu. P.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.90-96
    • /
    • 1998
  • Non-contacting capacitive sensors, based on principle of the cross capacitor, for measuring small displacement less than $1.95{\pm}0.5\;mm$ have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors with 2-electrodes and 3-electrodes, the new sensor is consisted of 4-electrodes which are formed two electrode(high, low) and 2 guard electrodes on a sapphire plate with diameter 17 mm and thickness 0.7 mm, and are symmetrically situated with a constant gap of 0.2 mm between the electrodes. This sensor can be used for measuring both metallic and non-metallic target without ground connection, and is evaluated to the correlation coefficient of 0.9987 for the range of $1.95{\pm}0.5\;mm$ and that of 0.9995 for $1.95{\pm}0.25\;mm$ range.

  • PDF

Correlation Between Joint Angular Displacement and Moment in the Human Foot (인체 족부관절의 각변위와 모멘트의 상관관계)

  • 김시열;신성휴;황지혜;최현기
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.209-215
    • /
    • 2003
  • The goal of this study was to investigate the relationship between kinematic and kinetic characteristics of foot joints resisting ground reaction force. Passive elastic joint moment and angular displacement were obtained from the experiment using 3 cameras and force plate. The relationship between joint angle and moment was mathematically modeled by using least square method. The ranges of motion of joints ranged from 5$^{\circ}$ to 7$^{\circ}$ except metatarsophalangeal joint. In the study, we presented simple mathematical models that could relate joint angle and plantar pressure. From this model, we can got the kinematic data of joints which is not available from conventional motion analysis. Furthermore, the model can be used not only for biomechanical model which simulates gait but also for clinical evaluation.

Development of Ceramic Pigment using Brass Scrap (각종 황동 Scrap를 사용한 Ceramic 안료 개발)

  • Kim, Jun-Ho;Jeon, Ok-Hyun;Suh, Man-Chul;Lee, Byung-Ha
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.6
    • /
    • pp.197-204
    • /
    • 2007
  • Ceramic pigments were developed by using 4 kinds of Brass scraps. Each Brass scraps were mixed with same weight-ratio of Husk ash, and fine-ground by Rotate ring mill(RRG-120, Armstech industrial. co. Ltd, Korea) after firing at $900^{\circ}C$, $1000^{\circ}C$ and $1100^{\circ}C$. As a result, analysis of particle size of synthetic pigments by particle size analyser, they are $3{\mu}m$ as average. The resulting pigments were characterized by using XRD, FT-IR, SEM Structure of the crystals are Zn2SiO4,, and ZnO, Cu2O, CuO, and cristobalite are existed and particles' shape are plate or needle. As a result of analysis of chemical composition by XRF, synthetic pigments have high SiO2 and CuO content and have SnO2, ZnO and NiO, too. 1wt%, 3wt% and 5wt% pigments were added in each lime glaze, lime-barium glaze and lime-magnesia glaze, and fired at oxidation and reducing atmosphere to figure hue in glazes out. As a result of analysis of color, chroma and brightness by UV, colors of glazes fired at oxidation atmosphere turned into green from sky blue, and colors of glazes fired at reducing atmosphere turned into pink and red.

Effect of Independent Suspension Function of Hiking Boots on the Stability and Load of Foot (등산화 아웃솔의 독립적 서스펜션 기능이 발의 안정성 및 부하에 미치는 효과)

  • Lee, Ki-Kwang;Choi, Chi-Sun;Eun, Seon-Deok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.115-119
    • /
    • 2006
  • To investigate the effects of independent suspension technology(IST) of hiking boot on the stability and load of foot, eight participants performed medial and lateral drop landing from 33.4cm height and 85cm distance to uneven surface while wearing normal & IST hiking boots. For the stability of foot during the drop landing, the balance angle & suspension angle and rearfoot angle was analyzed using high-speed video analysis. Also kinetic analysis using the force plate and insole pressure measurement was conducted to analyze vertical & breaking ground reaction force and pressure distribution. Not only the balance angle & suspension angle but also rearfoot angle was improved with IST boots for lateral drop landing. These results indicate the IST boots may have the suspension function which keeps the foot to be stable during landing. However the IST boots did not show any effect for medial landing. This might be related to the hardness of medial part of outsole. Therefore the softer outsole of medial part could be recommended. Furthermore the impact force & breaking force and insole pressure were reduced with IST boot. These results means that IST boot has not only cushioning effect but also good grip effect. Therefore the hiking boots applied the independent suspension function may help to reduce fatigue and prevent injury such as ankle sprain in hiking on uneven surface.

Gait Initiation in a Patient With Spastic Hemiplegia Cerebral Palsy With and Without a Dynamic Ankle Foot Orthosis: A Pilot Study (강직성 편측 뇌성마비 환자의 보행 기시에 미치는 동적 단하지 보조기의 효과: 사전연구)

  • Jeon, Hye-Seon;Senesac, Claudia;Kaufman, Elizabeth
    • Physical Therapy Korea
    • /
    • v.7 no.4
    • /
    • pp.39-46
    • /
    • 2000
  • 본 연구는 강직성 편측 뇌성마비 환자의 보행 기시(gait initiation)의 특성을 파악하고, 동적 단하지 보조기(dynamic ankle foot orthosis : DAFO)가 이런 환자들의 보행 기시에 미치는 영향을 알아보기 위하여 실시하였다. 연구대상자는 19세 선천성 강직성 우측 뇌성마비를 가진 여자 대학생이었다. 연구대상자는 4개의 다른 보행 기시 조건에서 각 조건당 7회의 보행 기시를 하였는데, 각각의 보행 기시 조건은: 1) 보조기 없이 좌측 하지로 보행 기시; 2) 우측 하지 보조기 착용 상태에서 좌측하지로 보행 기시; 3) 보조기 없이 우측 하지로 보행 기시; 4) 우측 하지 보조기 착용 상태에서 우측 하지로 보행 기시였다. 두개의 힘 판(force plate) 위에서 본인이 선택한 가장 편안한 방법과 속도로 2 m를 걷도록 하였다. 연구대상자가 보행 기시를 하는 동안 양쪽 가자미근과 앞정강근에 부착된 4개의 표면 전극으로부터 근 전도 신호와 보행 기시를 하는 연구 대상의 양 발 아래 놓인 두개의 힘 판의 자료를 분석하여 체중(body weight : BW)으로 정량화 하였다. 실험결과는 각 조건마다 7회 실시된 측정값들의 평균을 이용하였다. 본 사전연구의 결과는 다음과 같다. 1. 보행 기시 전 양다리로 선 상태에서 환측보다 건측으로 많은 체중지지를 하였으나(환측 42.57%BW, 건측 58.03%BW) 보조기의 착용이 환측으로의 체중지지를 향상시켰다(환측 44.46%BW, 건측 55.54%BW). 2. 보행 기시 중 가자미근과 앞정강근의 동시수축(coactivation)이 계속되었는데 이러한 양상은 보조기의 착용 유무에 따라 크게 달라지지 않았다. 3. 힘 판에서 들어온 지면 반발력(ground reaction force)의 수직 분력(vertical element, Fz)과 전후 분력(anterior-posterior element, Fx)을 분석한 결과, 건측 다리로 보행 기시를 할 때 보조기 착용은 가속을 촉진시켜 역학적으로 유리하였다. 이상의 연구 결과는 보조기의 착용이 건측 다리로 보행 기시를 할 때 미치는 신경학적, 역학적 장점들에 대한 구체적 연구의 필요성 및 근거를 제시하고, 환자들의 보행훈련 접근에 보다 효율적인 보행방법을 소개하는데 이용될 수 있다.

  • PDF

Compact Range Detection Sensor by Oscillation Frequency Deviation of an Active Antenna (능동안테나의 발진주파수 편이에 의한 소형 거리 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.528-535
    • /
    • 2011
  • In this paper, a compact doppler sensor with oscillator type active antenna operating at 2.4GHz frequency band is proposed to measure the distance to a moving object. The oscillation frequency is shifted depending on approaching of the object, and a detection circuit discriminates the frequency deviation. The active antenna has been designed and simulated. The prototype fabricated has a small circular disk type of diameter 30mm and height 4.2mm. As for antenna performance, broadside radiation pattern with beamwidth of $120^{\circ}$ and oscillation frequency of 2.35GHz has been measured. Test results as a range sensor shows that signal voltage of about 240mV has been obtained for conducting plate moving 1 meter away from the sensor. And, signal voltage has been linearly increased to the ground from 5m height by free-falling the sensor.

Load-transfer mechanism in the ground with discontinuity planes during tunnel excavation (불연속면이 존재하는 지반에서 터널굴착에 의한 하중전이)

  • Lee, Sang-Duk;Byun, Gwang-Wook;Yoo, Kun-Sun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.1
    • /
    • pp.71-78
    • /
    • 2002
  • In this study, the influence of the presence of discontinuity planes on the load transfer mechanism and the pattern of loosening zone was studied based on the laboratory test. The trap-door and the reaction plates are installed as the bottom plane of the model box. The vertical discontinuity plane is installed in the dry sand. Various overburden heights and locations of discontinuity planes are applied as major factors in this study. The results show that at higher overburden heights over about 1.5 times the excavation width, the ratio of the transferred stress to the insitu stress converges to a certain value even if the overburden height increases further. The results also show that the discontinuity plane gives relatively larger influence on the load transfer mechanism, that produces the unsymmetrical load concentration, when the discontinuity plane locates within the tunnel width. When the discontinuity plane locates outside the tunnel width, the unsymmetrical load concentration is reduced considerably.

  • PDF