• Title/Summary/Keyword: Ground Fixed Environment

Search Result 47, Processing Time 0.026 seconds

Failure Rate Characteristics Analysis under Ground Mobile and Ground Fixed Environments (지상 기동 및 고정 환경하 고장률 특성 분석)

  • Yun, Hui-Sung;Jeong, Da-Un;Yoon, Jong-Sung;Lee, Seung-Hun
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.293-303
    • /
    • 2011
  • Reliability Prediction using MIL-HDBK-217F has some restrictions due to its one modeling basis. One of the restrictions is caused by selecting one operating environment of a system, which is chosen regardless of its detailed conditions, e.g., external impact and vibration. Especially, an equipment, which is installed on a mobile vehicle though its movement is quasi-static, is controversial to designate its environment as ground mobile($G_M$), rather than ground fixed($G_F$). In this paper, failure rates were compared, which are computed using several moving time rates to total operating time. RiAC-HDBK-217Plus was used as the basic calculation model. In addition, $G_F$ conditioned failure rate was evaluated by comparing with that under $G_M$ environment but fixed state.

Experimental Study on the Ground Support Conditions of Pipe Ends in Single Span Pipe Greenhouse (단동파이프하우스의 지점조건 분석을 위한 실험 연구)

  • Lee, Suk-Gun;Lee, Jong-Won;Kwak, Cheul-Soon;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.188-196
    • /
    • 2008
  • Single span pipe greenhouses (pipe houses) are widely used in Korea because these simple structures are suitable for construction by farmers thus reducing labor cost. However, these pipe houses are very weak and frequently damaged by heavy snow and strong wind. Pipe house is constructed by pipe fabricator, which is anchored to the ground by inserting each pipe end into ground to $30\sim40cm$, so the ground support condition of pipe end is not clear for theoretical analysis on greenhouse structure. This study was carried out to find out the suitable ground support condition needed f3r structural analysis when pipe house was designed. The snow and wind loading tests on the actual size pipe house were conducted to measure the collapsing shape, displacement and strain. The experimental results were compared with the structural analysis results for 4 different ground support conditions of pipe ends(fixed at ground surface, hinged at ground surface, fixed under ground and hinged under ground). The pipe house under snow load was collapsed at the eaves as predicted, and the actual strain at the windward eave and ground support under wind load was larger than that under snow load. The displacement was the largest at the hinged support under ground, followed by the hinged at ground surface, the fixed under ground and then the fixed at ground surface independent of displacement direction and experimental loading condition. The experimental results agreed most closely with the results of theoretical analysis at the fixed condition under ground among 4 different ground support conditions. As the results, it was recommended that the pipe end support condition of single span pipe greenhouse was the fixed under ground for structural analysis.

Study on Reflectance and NDVI of Aerial Images using a Fixed-Wing UAV "Ebee"

  • Lee, Kyung-Do;Lee, Ye-Eun;Park, Chan-Won;Hong, Suk-Young;Na, Sang-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.6
    • /
    • pp.731-742
    • /
    • 2016
  • Recent technological advance in UAV (Unmanned Aerial Vehicle) technology offers new opportunities for assessing crop situation using UAV imagery. The objective of this study was to assess if reflectance and NDVI derived from consumer-grade cameras mounted on UAVs are useful for crop condition monitoring. This study was conducted using a fixed-wing UAV(Ebee) with Cannon S110 camera from March 2015 to March 2016 in the experiment field of National Institute of Agricultural Sciences. Results were compared with ground-based recordings obtained from consumer-grade cameras and ground multi-spectral sensors. The relationship between raw digital numbers (DNs) of UAV images and measured calibration tarp reflectance was quadratic. Surface (lawn grass, stairs, and soybean cultivation area) reflectance obtained from UAV images was not similar to reflectance measured by ground-based sensors. But NDVI based on UAV imagery was similar to NDVI calculated by ground-based sensors.

Analysis and modeling of DGPS antenna performance depending on the DGPS site environment (DGPS 기준국 사이트 환경에 따른 안테나 성능 모델링 해석)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.5
    • /
    • pp.1022-1027
    • /
    • 2014
  • Based on the modeling of DGPS antenna and antenna site environment, the DGPS short-monopole antenna performance according to the antenna surrounding environment are analyzed in this paper. The DGPS antenna site modeling that considers the ground conductivity and radio wave obstacles is performed and the general requirements for DGPS antenna site are proposed. In case of antenna site with proper radials on the ground plane of the fixed scale, the effect for antenna matching network due to the ground conductivity and radio wave obstacles is small but the impact on the radiation efficiency is large. To provide the stable DGPS service, it is important to install the DGPS antenna on the flat ground plain with good conductivity and without radio wave obstacles.

The Study of Improve Safety for Signaling System using Communication (통신에 의한 신호시스템의 안전성 확보에 대한 연구)

  • 백종현;한성호;안태기;온정근
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.307-314
    • /
    • 1999
  • The potential use of ranging sensors for reducing the occurrence of accidents in real environment is explored by many companies and laboratories. Most of the sensors under investigation utilize the FMCW(Frequency Modulated Continuous Wave) waveforms. The automotive environment presents to the FMCW radar sensor a multitude of moving and fixed targets and the sensor must detect and track only the targets which may pose a threat of collision or passengers accident. The sensor must function accurately in the presence of background echoes generated by moving and fixed targets, ground reflections, atmospheric noises, including rains, fog, and, snow and noise generated within the receiver. False detection of the desired target in this environment may issue false alarms. That may be dangerous to the passenger and the vehicle. A high false alarm rate is totally unacceptable. The false alarm mechanism consists of noise peaks, crossing the threshold and the undesired response of the system to off lane targets which are not potentially hazardous to the radar equipped vehicle. This paper presents an improve technique safety performance for driver-less operation using FMCW radar sensors.

  • PDF

Extended and Adaptive Inverse Perspective Mapping for Ground Representation of Autonomous Mobile Robot (모바일 자율 주행 로봇의 지면 표현을 위한 확장된 적응형 역투영 맵핑 방법)

  • Jooyong Park;Younggun Cho
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2023
  • This paper proposes an Extended and Adaptive Inverse Perspective Mapping (EA-IPM) model that can obtain an accurate bird's-eye view (BEV) from the forward-looking monocular camera on the sidewalk with various curves. While Inverse Perspective Mapping (IPM) is a good way to obtain ground information, conventional methods assume a fixed relationship between the camera and the ground. Due to the nature of the driving environment of the mobile robot, there are more walking environments with frequent motion changes than flat roads, which have a fatal effect on IPM results. Therefore, we have developed an extended IPM process to be applicable in IPM on sidewalks by adding a formula for complementary Y-derive processes and roll motions to the existing adaptive IPM model that is robust to pitch motions. To convince the performance of the proposed method, we evaluated our results on both synthetic and real road and sidewalk datasets.

The Study of Improved Safety of Signalling System using Communication (통신에 의한 신호시스템의 안전성 확보에 관한 연구)

  • Baek, Jong-Hyen;Wang, Jong-Bae;Byun, Yeun-Sub;Park, Hyun-Jun;Han, Young-Jae;Kim, Kil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1368-1370
    • /
    • 2000
  • The automotive environment presents to the FMCW radar sensor a multitude of moving and fixed targets and the sensor must detect and track only the targets which may pose a threat of collision or passengers accident. The sensor must function accurately in the presence of background echoes generated by moving and fixed targets, ground reflections, atmospheric noises, including rains, fog, and, snow and noise generated within the receiver. False detection of the desired target in this environment may issue false alarms. That may be dangerous to the passenger and the vehicle. A high false alarm rate is totally unacceptable. The false alarm mechanism consists of noise peaks, crossing the threshold and the undesired response of the system to off lane targets which are not potentially hazardous to the radar equipped vehicle. This paper presents an improve technique safety performance for driver-less operation using FMCW radar sensors.

  • PDF

An Estimation of Behavior for Wedge type Removable Soil Nailing System by Field Trial Construction (현장시험시공을 통한 쐐기형 제거식 쏘일네일링 공법의 거동 평가)

  • Han, Yeon-Jin;Park, Si-Sam;Kwon, Hyuk-Jun;Kim, Hong-Taek;Park, Ju-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1360-1364
    • /
    • 2009
  • Necessity of removable soil nailing has been arisen in the soil nailing system because of problem such as civil petition for geotechnical environment and invasion of the ground boundary line and payments for use besides geotechnical engineering. Removable soil nailing system is improved soil nailing system that fixed socket arranged in boring hole for increasement of skin friction. In this study, field pull-out tests are carried out more 4 times considering installed distance of fixed socket and analyze skin friction behavior characteristics in fixed socket through analysis of measurements of strain gauge attached to fixed socket. Also, to evaluate application for wedge type removable soil nailing system analyzing displacement aspects through field pull-out tests by trial construction.

  • PDF

Measurements of Dark Area in Sensing RFID Transponders

  • Kang, J.H.;Kim, J.Y.
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • Radiofrequency(RF) signal is a key medium to the most of the present wireless communication devices including RF identification devices(RFID) and smart sensors. However, the most critical barrier to overcome in RFID application is in the failure rate in detection. The most notable improvement in the detection was from the introduction of EPC Class1 Gen2 protocol, but the fundamental problems in the physical properties of the RF signal drew less attention. In this work, we focused on the physical properties of the RF signal in order to understand the failure rate by noting the existence of the ground planes and noise sources in the real environment. By using the mathematical computation software, Maple, we simulated the distribution of the electromagnetic field from a dipole antenna when ground planes exist. Calculations showed that the dark area can be formed by interference. We also constructed a test system to measure the failure rate in the detection of a RFID transponder. The test system was composed of a fixed RFID reader and an EPC Class1 Gen2 transponder which was attached to a scanner to sweep in the x-y plane. Labview software was used to control the x-y scanner and to acquire data. Tests in the laboratory environment showed that the dark area can be as much as 43 %. One who wants to use RFID and smart sensors should carefully consider the extent of the dark area.

Applications of Drones for Environmental Monitoring of Pollutant-Emitting Facilities

  • Son, Seung Woo;Yu, Jae Jin;Kim, Dong Woo;Park, Hyun Su;Yoon, Jeong Ho
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.2 no.4
    • /
    • pp.298-304
    • /
    • 2021
  • This study aimed to determine the applicability of drones and air quality sensors in environmental monitoring of air pollutant emissions by developing and testing two new methods. The first method used orthoimagery for precise monitoring of pollutant-emitting facilities. The second method used atmospheric sensors for monitoring air pollutants in emissions. Results showed that ground sample distance could be established within 5 cm during the creation of orthoimagery for monitoring emissions, which allowed for detailed examination of facilities with naked eyes. For air quality monitoring, drones were flown on a fixed course and measured the air quality in point units, thus enabling mapping of air quality through spatial analysis. Sensors that could measure various substances were used during this process. Data on particulate matter were compared with data from the National Air Pollution Measurement Network to determine its future potential to leverage. However, technical development and applications for environmental monitoring of pollution-emitting facilities are still in their early stages. They could be limited by meteorological conditions and sensitivity of the sensor technology. This research is expected to provide guidelines for environmental monitoring of pollutant-emitting facilities using drones.