• Title/Summary/Keyword: Ground

Search Result 22,704, Processing Time 0.042 seconds

The Effect of the Artificial Ground on Building Thermal Environment (인공지반이 건물 열환경에 미치는 효과에 관한 연구)

  • Hwang, Hyo-Keun;Lim, Jong-Yeon;Ryu, Min-Kyung;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.170-175
    • /
    • 2009
  • Apartment housing block has been spreaded according to rapid economic development and urbanization in Korea. A parking lot is located at underground, artificial ground is inevitably created in apartment housing block. Artificial ground creates different thermal environment compared to natural ground, because the composition and coverage of artificial ground are diverse. In this study, the effect of the artificial ground on building thermal environment will be disscussed by simulation. Considering the result of simulation, surface albedo is more important for building energy performance. A purpose of this study is to examine how the characteristic of surface effect to thermal environment, and to develop design method for sustainable outdoor space.

  • PDF

Development of low-cost, low-depth unit-type ground heat exchanger (저심도 저비용 유닛형 지중열교환기의 개발)

  • Oh, Jin-Hwan;Nam, Yujin;Chae, Ho-Byung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.166-167
    • /
    • 2014
  • Recently, in according to increase cognizance of energy and resources exhaustion, renewable energy system is received attention. In particular, ground heat pump system(GSHP) utilizing annually stable ground temperature for energy saving have been attracted in many buildings. However, GSHP system have disadvantage due to increase of initial installation and boring cost. In this study, in order to reduce the initial cost and to supply ground heat pump system into small scale house, an unit-type ground heat exchanger was developed.

  • PDF

Case Study of Ground and Supporting System Failure in Soft Ground Deep Excavation (연약지반 깊은 굴착에서 지보재 및 지반 파괴 사례 연구)

  • Kim, Sung-Wook;Han, Byung-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.537-544
    • /
    • 2005
  • We find out many soft ground deep excavation cases where results of careless overexcavation accelerate the advance of loosening zone of adjacent ground, bucklings of struts and bottom heaves happen due to delayed supporting time. This article introduces a soft ground deep excavation case where steel pipe sheet piles were used with struts as an earth retaining system. There were 2 times of buckling in the supporting system and heaving of bottom ground due to overexcavation and insufficient penetration depth of the steel pipe sheet piles. The effort of this article aims to improve and develop the technique of design and construction in the coming projects having similar ground condition and supporting method.

  • PDF

A Failure of disturbed natural-slope ground caused by cutting slope (절토에 의한 상부자연지반의 붕괴 특성 연구)

  • Nah, Kwang-Hee;Chang, Buhm-Soo;Shin, Chang-Gun;Kim, Yong-Soo;Choi, Yong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.629-634
    • /
    • 2004
  • When it was a localized torrential downpour last year, a natural-slope fell down above a cut-slope. They were caused that stress was opened by cutting slope, ground water level rose quickly and a ground mass strength fell etc. So volume of ground mass increase because of that reasons, finally the disturbed ground was collapse. Therefore I suggest that safety of a natural-slope is a consideration, when a cut-slope is made by cutting ground.

  • PDF

Assessment of Code-specified Ground Motion Selection Criteria with Accurate Selection and Scaling Methods - I Ground Motion Selection (구조물 동적해석을 위한 현행 내진설계기준의 입력 지반 운동 선정 조건 타당성 평가 - I 선정방법)

  • Ha, Seong Jin;Han, Sang Whan;Ji, Hyun Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.171-179
    • /
    • 2017
  • For estimating the seismic demand of buildings, most seismic design provisions permit conducting linear and nonlinear response history analysis. In order to obtain reliable results from response history analyses, a proper selection of input ground motions is required. In this study, an accurate algorithm for selecting and scaling ground motions is proposed, which satisfies the ASCE 7-10 criteria. In the proposed algorithm, a desired number of ground motions are sequentially scaled and selected from a ground motion library without iterations.

Wake Shapes Behind Wings in Close Formation Flight Near the Ground

  • Han Cheolheui;Cho Leesang;Cho Jinsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.674-681
    • /
    • 2005
  • The unsteady evolution of trailing vortex sheets behind wings in close formation flight near the ground is simulated using a discrete vortex method. The ground effect is included by an image method. The method is validated by comparing computed results with other numerical results. For a lifting line with an elliptic loading, the ground has an effect of moving wingtip vortices laterally outward and suppressing the development of vortex evolution. The gap between wings in close formation flight has an effect of moving up wingtip vortices facing each other. For wings flying in parallel, the ground effect causes the wingtip vortices facing each other to move up, and it makes the opposite wing tip vortices to move laterally outward. When there is a relative height between the wings in ground effect, right-hand side wingtip vortices from a mothership move laterally inward.

Enhanced dissolution rates of piroxicam from the ground mixtures with chitin or chitosan

  • Koh, Ik-Bae;Shin, Sang-Chul;Lee, Yong-Bok
    • Archives of Pharmacal Research
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1986
  • To increase the dissolution rate of piroxicam, chitin and chitosan which are widely occurring biodegradable natural materials were used as drug carriers. The ground mixtures of piroxicam with chitin or chitosan were prepared by grinding in a ball mill. The dissolution rates of piroxicam from the ground mixtures were enhanced markedly than that from the physical mixtures or from intact piroxicam. The X-ray diffraction peaks disappeared in the ground mixture indicating the production of the amorphous form. The comparison of infrared spectra of the physical mixture and the ground minture showed an interaction such as association between the functional groups of piroxicam and chitin or chitosan in the molecular level. The weight losses in TGA curves shoed all the same patterns. However, in the ground mixture by DTA curve, the undothermic peak due to the fusion of piroxicam was disappeared indicating the different thermal property.

  • PDF

TBM considerations for soft-ground tunnels

  • Rozgonyi T. G.;Kieffer D. S.;Maidl U.;Bald Cernal
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.42-51
    • /
    • 2003
  • The global demand for underground facilities has increased substantially in the past decades, and a substantial number of underground projects have had to deal with challenging ground conditions in urban environments. Particularly challenging are weak and unstable water bearing soils. Advancements in shielded TBM tech-nology have led to significant improvements regarding the ability to control ground deformations in soft ground. Nonetheless, ground collapse may occur even when the most advanced TBM designs are employed if unexpected adverse ground conditions are encountered or if insufficient stabilizing pressure is transferred to the tunnel face. This paper reviews common approaches for face stability and face pressure transmission calculations, and provides an overview of some of the latest technological developments and considerations for soft ground TBM applica-tions.

  • PDF

The Method for detecting ground fault between power part and controller part of a electricity vehicle (전기동력 자동차 구동부와 제어부 간 절연고장 검출 방법)

  • Park, Hyun-Seok;Cho, Se-Bong;Jeon, Ywun-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.174-176
    • /
    • 2007
  • Because of accident or leak of electricity, high voltage electricity can be conducted to vehicle chassis and damage human. Therefore the unit for detecting ground fault is necessary to minimize loss of life or equipment damage. Isolation resistance must be monitored for detecting ground fault. GFD(Ground Fault Detection) unit continually generate the pulse voltage between high voltage network and chassis. This will be sensing the returned current, calculate the isolation resistance and make decision the ground fault. This paper describes the method detecting ground fault.

  • PDF

An Experimental Study on the Performance of Semi-Closed Loop Ground Heat Exchanger (반밀폐형 지중열교환기 성능에 관한 실험적 연구)

  • Kim, Ook-Joong;Yeom, Han-Kil;Lee, Chun-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.542-545
    • /
    • 2007
  • A semi-closed loop ground heat exchanger is proposed and its performance is compared through the measuring the effective thermal conductivity of the ground. In-situ tests based on the line source model are carried out to evaluate the thermal characteristics of each ground heat exchanger which has different penetration water flow rate. The test results show the increasing effective thermal conductivity of ground as the penetration water flow rate(PWFR) is increased. Therefore, the higher thermal performance of the proposed semi-closed ground heat exchanger can be expected.

  • PDF