• Title/Summary/Keyword: Gross system

Search Result 482, Processing Time 0.028 seconds

A Study on the Operational Improvement at Pusan Container Terminal (부산항 컨테이너 전용 터미널 운영 개선을 위한 연구)

  • 허윤수;하원익;정승호
    • Journal of Korean Port Research
    • /
    • v.14 no.1
    • /
    • pp.13-26
    • /
    • 2000
  • In this paper, we compare and analyze the current state of the productivity of the stevedoring work among several container terminals in 1999. Based on these results of analysis, we firstly classify several factors which impede the efficient operations of container terminal as follows ; late arrival of container beyond cargo closing time(CCT), change of port of destination, change of vessel, and return cargo. Such factors are major cause for the cargo rehandling on terminals, thus deteriorate the overall performance of transfer crane during the stevedoring work. In order to improve the productivity of container terminal, we suggest that it is necessary for establishing and operating the efficient logistics management system. Especially, we emphasize the importance of information exchange on the scheduled cargoes among the relevant parties such as shippers, shipping companies, and terminal operators, which is the most effective way to alleviate the cargo rehandling.

  • PDF

Performance Analysis of OTEC Power Plant (해양온도차 발전 플랜트 성능해석)

  • Uhm, Ji-Hong;Lee, Jae-Yong;Kim, Nam-Jin;Kim, Chong-Bo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.234-240
    • /
    • 2000
  • The Energy is the basis for almost all industrial activities and domestic needs. But recently there are increasing concerns internationally over environmental problems and consequent climate changes caused by the excessive use of fossil fuels. Furthermore the price of crude oil is increasing steadily with unstable supplies. In order to solve these national energy problems, the utilization of Ocean Energy is introduced as one of the best alternative technologies for the future. OTEC Power Plant has been installed at the West Inchon Power Plant Site. Temperature differences of $20{\sim}25^{\circ}C$ have been utilized for plant operations, where R22 is used as a working fluid. The system is composed of low pressure turbine, plate type heat exchanger, and pumps. In the present investigation the experimental results, such as gross power, net power and objective function, are analysed when temperature differences change from the reference design point.

  • PDF

Studies on infection rate and histopathological findings of canine heartworms in Inchon city (인천 지역 사육견의 심장사상충 감염률 및 병리조직학적 연구)

  • 이성모;황현순;김종훈
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.1
    • /
    • pp.25-35
    • /
    • 1999
  • The prevalence of canine heartworm(Dirofilaria immitis) infection in 150 mixed-breed dogs(male : 54, female : 96) from February to December 1997 was investigated by using antigen test kit(ICT $GOLD^{TM}$ HW, Synbiotics, USA) based on immunochromatographic assay in Inchon city. Also, gross and histopathological findings of an antigen positive dog were carried out. The results were summarized as follows ; 1. Four dogs were positive from 150 tested dogs(2.7%). They were all more than 2 years old and infection rates in male and outdoor dogs was higher than those in female and indoor, respectively. Species of infected dogs were Pug(2) , German Sheperd(1) and Great-dane (1). 2. Regional infection rates were closely related with housing system in the city. 3. Pathological findings of antigen-positive dog was excessive enlargement, congestion and hemorrhage of lung and D immitis in heart and histologically hemosiderin, hypertrophy of pulmonary alveoli wall and irregular hypertrophy of pulmonary artery inner wall. Microfilaria was observed in pulmonary artery and arteriole, ventricle and splenic artery.

  • PDF

20kw급 해양온도차 파이롯 플랜트 성능실험

  • 엄지홍;이재용;김남진;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.1002-1008
    • /
    • 2001
  • The energy is the basis for almost all industrial activities and domestic needs. But recently there are increasing concerns internationally over environmental problems and consequent climate changes caused by the excessive use of fossil fuels. Furthermore the price of crude oil is increasing steadily with unstable supplies. In order to solve these national energy problems, the utilization of Ocean Energy is introduced as one of the best alterative technologies for the future. OTEC Power Plant has been installed at the West Inchon Power Plant Site. Temperature differences of$20~25^{\circ}C$ been utilized for plant operations, where R22 is used as a working fluid. The system is composed of low pressure turbine, plate type heat exchanger, and pumps. In the present investigation the experimental results, such as gross power, net power and objective function, are analysed when temperature differences change from the reference design point.

  • PDF

A Study on Measuring Method in Technical Progress (기술진보 측정방법에 관한 일고안)

  • 박일근
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.59-66
    • /
    • 1980
  • The purpose of this paper to study on measuring method in technical progress. Technology is combination method of raw material and capital, land, labour. The first step to technical Progress is COBB-DOUGLAS production function, so technical progresses are important role in economic growth and development. General production function from Y=f(K, L, T) and COBB-DOUGLAS production function Y=${AK^I}{L^b}$ is first condition. Technical progress is saving of production factor In capital saving, labour saving, neutral saving. Marred Hicks Robinson has Insist on technical progress by each view of production factor, but, what is most excellent measuring method of technical progress\ulcorner I : productivity index method. II : Gross Production function method. Productivity method used in every products level in weight values, gross method function method used in production factor attributed to products. Above two measuring method has delicate problem in each input factor, substitution relation and production factor simultaneously linked each others This basic problem based on technical progress is not solubable in this time.

  • PDF

Clinical Manifestation Patterns and Trends in Poststreptococcal Glomerulonephritis

  • Kim, Kee Hyuck
    • Childhood Kidney Diseases
    • /
    • v.20 no.1
    • /
    • pp.6-10
    • /
    • 2016
  • Poststreptococcal glomerulonephritis (PSGN) is one of the most recognized diseases in pediatric nephrology. Typical clinical features include rapid onset of gross hematuria, edema, and hypertension, and cases are typically preceded by an episode of group A ${\beta}$-hemolytic streptococcus pharyngitis or pyoderma. The most common presenting symptoms of PSGN are the classic triad of glomerulonephritis: gross hematuria, edema, and hypertension. However, patients with PSGN sometimes present with unusual or atypical clinical symptoms that often lead to delayed diagnosis or misdiagnosis of the disease and increased morbidity. Additionally, the epidemiology of postinfectious glomerulonephritis (PIGN), including PSGN, has changed over the past few decades. This paper reviews atypical clinical manifestations of PSGN and discusses the changing demographics of PIGN with a focus on PSGN.

Radiologic Findings of Renal Hemangioma: Report of Three Cases

  • Hak-Soo Lee;Byung-Hee Koh;Jang-Wook Kim;Yong-Soo Kim;Hyun-Chul Rhim;On-Koo Cho;Chang-Kok Hahm;Young-Nam Woo;Moon-Hyang Park
    • Korean Journal of Radiology
    • /
    • v.1 no.1
    • /
    • pp.60-63
    • /
    • 2000
  • Renal hemangioma is an uncommon benign tumor which usually causes painless or painful gross hematuria. Its preoperative diagnosis is extremely difficult or even impossible. We experienced three cases of renal hemangioma, located mainly at the pelvocalyceal junction or in the inner medulla. US demonstrated variable echogenecity, and CT revealed a lack of significant enhancement. Where there is gross hematuria in a young adult, especially when the renal mass located in the pelvocalyceal junction or inner medulla shows little enhancement on CT, renal hemangioma should form part of the differential diagnosis.

  • PDF

A Study on the Classification of Inventory Items (재고품목의 분류에 관한 연구)

  • 이상도;이강우
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.13 no.21
    • /
    • pp.61-72
    • /
    • 1990
  • In the past, a fundamental technique in inventory control system was to rank the items of a inventory from a distribution by value to draw an ABC curve. Unfortunately the use of ABC categorization technique has created problems and introduced some gross errors into the inventory control system. First, the author considers the possible applications of the technique in the real world and then attempts to discuss ABC fallacies through the literatures. Finally, an inventory categorization algorithm by the principal component analysis is derived and a numerical example is also presented to illustrate the algorithm.

  • PDF

Risk Assessment for Abolition of Gross Containment Leak Monitoring System Test in CANDU Design Plant (중수로 원자로건물 총누설감시계통 시험 중지에 따른 리스크 영향 평가)

  • Bae, Yeon-Kyoung;Na, Jang-Hwan;Bahng, Ki-In
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.123-130
    • /
    • 2015
  • Wolsong Unit 2,3&4 has been performing a containment integrity test during power operation. This test could impact to the safe operation during test. If an accident occurs during pressure dropping phase, reactor trip can be delayed because of the increased pressure difference which causes a time delay to reach the trip set-point. On the contrary, if an accident occurs during pressure increasing phase, reactor trip could be accelerated because the pressure difference to the trip set-point decrease. Point Lepreau nuclear power plant, which installed GCLMS (Gross Containment Leakage Monitoring System) in 1990, has discontinued the test since 1992 due to these adverse effects. Therefore, we evaluated the risk to obviate the GCLMS test based on PWR's ILRT (Integrated Leak Rate Test) extension methodologies. The results demonstrate that risk increase rate is not high in case of performing only ILRT test at every 5 years instead of doing GCLMS test at every 1.5 years. In addition, the result shows that GCLMS test can be removed on a risk-informed perspective since risk increasement is in acceptable area of regulatory acceptance criteria.

Thickness of shear flow path in RC beams at maximum torsional strength

  • Kim, Hyeong-Gook;Lee, Jung-Yoon;Kim, Kil-Hee
    • Computers and Concrete
    • /
    • v.29 no.5
    • /
    • pp.303-321
    • /
    • 2022
  • The current design equations for predicting the torsional capacity of RC members underestimate the torsional strength of under-reinforced members and overestimate the torsional strength of over-reinforced members. This is because the design equations consider only the yield strength of torsional reinforcement and the cross-sectional properties of members in determining the torsional capacity. This paper presents an analytical model to predict the thickness of shear flow path in RC beams subjected to pure torsion. The analytical model assumes that torsional reinforcement resists torsional moment with a sufficient deformation capacity until concrete fails by crushing. The ACI 318 code is modified by applying analytical results from the proposed model such as the average stress of torsional reinforcement and the effective gross area enclosed by the shear flow path. Comparison of the calculated and observed torsional strengths of existing 129 test beams showed good agreement. Two design variables related to the compressive strength of concrete in the proposed model are approximated for design application. The accuracy of the ACI 318 code for the over-reinforced test beams improved somewhat with the use of the approximations for the average stresses of reinforcements and the effective gross area enclosed by the shear flow path.