• Title/Summary/Keyword: Grip length

Search Result 42, Processing Time 0.024 seconds

Association between muscular strengths and gait characteristics of elderly people aged 65 to 74 and 75 and above (전·후기 노인의 근력과 보행 특성의 관계)

  • Back, Chang-Yei;Joo, Ji-Yong;Kim, Young-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.415-422
    • /
    • 2020
  • This study investigates the relationship between muscular strengths and gait characteristics of the elderly. Totally, 107 subjects, aged 65 to 85 years, participated in this study. Researchers measured muscle strengths (grip force, toe grip force, gluteus medius, and gluteus maximus forces) and walking characteristics (walking speed, cadence, step length, single leg support, and double legs support). Dynamometers and inertial measurement unit-based shoe systems were used for measuring muscular strength and gait characteristics, respectively. No significant difference was observed in strengths and walking characteristics between the young elders (YE, 65-74 years) and the old elders (OE, 75-85 years). For each age, muscular strength significantly correlated with some gait parameters. Forces of gluteus medius and gluteus maximus muscles showed better significant correlations between some gait parameters for all age groups, as compared to grip force and toe grip force. Regression coefficients between walking speed and grip force did not vary with age. We conclude that muscular strengths in OE better explained the gait characteristics than in YE subjects. Even though grip strength is an easily measured variable for senior fitness test, forces of gluteus medius and gluteus maximus muscles are more meaningful for understanding the walking characteristics of elderly people.

Tension Based 7 DOEs Force Feedback Device: SPIDAR-G

  • Kim, Seahak;Yasuharu Koike;Makoto Sato
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • In this paper, we intend to demonstrate a new intuitive force-feedback device for advanced VR applications. Force feed-back for the device is tension based and is characterized by 7 degrees of freedom (DOF); 3 DOF for translation, 3 DOF for rotation, and 1 DOF for grasp). The SPIDAR-G (Space Interface Device for Artificial Reality with Grip) will allow users to interact with virtual objects naturally by manipulating two hemispherical grips located in the center of the device frame. We will show how to connect the strings between each vertex of grip and each extremity of the frame in order to achieve force feedback. In addition, methodologies will be discussed for calculating translation, orientation and grasp using the length of 8 strings connected to the motors and encoders on the frame. The SPIDAR-G exhibits smooth force feedback, minimized inertia, no backlash, scalability and safety. Such features are attributed to strategic string arrangement and control that results in stable haptic rendering. The design and control of the SPIDAR-G will be described in detail and the Space Graphic User Interface system based on the proposed SPIDAR-G system will be demonstrated. Experimental results validate the feasibility of the proposed device and reveal its application to virtual reality.

Kinematical Analysis of Men's Pole Vault Event (장대높이뛰기 경기의 운동학적 분석)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.15-26
    • /
    • 2003
  • This study was conducted to investigate the performance times, CM position and CM speed, pole chord length and pole chord angle, whole body angular momentum(X axis), and grip width in pole vault event according to the event and phase; touch down, pole plant, take-off, maximum pole bending pole straight, pole release, peak height, and foot contact, pole contact, free flight. The pole vaulting of four male elite vaulters including six trial were filmed using two video digital cameras at 60 Hz at 56th national athletic match, and data were collected through the DLT method of three dimensional cinematography. In general the better jumper is, the longer the performance time is. And the greater CM speed is, and the better his transformation ability of CM horizontal speed into vertical speed is. As he uses a longer pole, his grip is higher, and it is a enough for him to rock back his body, so that he pulls and pushes the pole well keeping his hips close to. An greater maximum angular momentum and early positioning of the hips parallel to the bar makes his body far side of the bar and his bar clearance easier. Specially our national jumper needs to have more powerful braking force during foot contact phase, and take his body on the pole after maximum pole bending, and pull and push the pole strongly keeping his hips close to. Also he needs to have stronger muscular strength in order to control the longer pole and use the pole of proper tension more efficiently.

A study on the fastening performance and finger function of the cerebral palsied (뇌성마비자의 의복여밈 수행능력과 수지기능)

  • 김순분;함옥상;서승록
    • Journal of the Ergonomics Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.45-62
    • /
    • 1993
  • This study was aimed to obtain the available information for the clothing constru- ction according to the traits of the cerebral palsied. For this purpose, their abilities of eleven methods seven of fastening performance and seven finger functions were tested and their correlationships were clarified. The results are as follows : 1. The length of time needed to perform each fastening method in descending order is as follows : small button > small snap > culumn button > large button > middle button > large snap > separating zipper > velcro. As the spastic has better function than the athetoid in the performance of all fastening methods, there was a significant difference between the types of handicap and between the handi- capped and the normal, except for velcro fastening style in which there was no significant differ- ence between the types of handicap. 2. In finger functions of the cerebral palsied, according to the types of handicap there was no significant difference among grip, palm fixation and hands coordination, howefer there were significant differences among pulp pinching, lateral pinching, finger rolling and lifting control. As to the correlation between the ability of fastening performance and finger function, there was a high significant correlation between the length of time needed to perform each fastenting and finger function of hands co ordination, and that of finger rolling; and there was a significant correlation between the length of time and pulp pinching, and laternal pinching.

  • PDF

Design of a Small Radio Frequency Identification Tag Antenna Using a Corrugated Meander Line Applicable to a Drug Runout Sensor System

  • Ko, Dong-Ok;Woo, Jong-Myung
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2018
  • This article proposes an ultrahigh frequency band radio frequency identification (RFID) tag antenna for drug runout management that can be used in hospitals. The RFID tag antenna is designed to function as a sensor that alerts drug runout when a drug inside a drip chamber is completely consumed but does not work when a drug remains inside a drop chamber. A previously proposed 915 MHz dipole antenna, is too large to be attached to the drip chamber of a feeding bag. Moreover, the length of the dipole (L) should be increased for conjugate matching with an RFID chip. Therefore, the dipole antenna is downsized so that it can be attached to the drip chamber through a fine meander line structure coupling with a corrugate meander line. A transparent cover is added to enhance the grip force between the designed antenna and the drip chamber and to enable detachment. The dimensions of the completed antenna structure attachable to a drip chamber are 32.59 mm (height) and 13.5 mm (width). The gain reduction due to the decreased antenna length is enhanced. The fabricated antenna shows an average omni-directional read range of 10.65 m on a horizontal plane and has the function of sensing the presence of a drug.

The Relationship between Standing Posture Biomechanics and Physical Fitness in the Elderly (노인의 직립자세역학과 체력과의 관계)

  • Yi, Kyung-Ock;Choi, Kyoo-Jeong;Kim, Soyoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2014
  • The purpose of this study was to find the relationship between standing posture biomechanics and physical fitness in the elderly. Physical fitness variables and postural variables for 227 (140 women and 87 men) elderly individuals were tested. Physical fitness tests (Korean Institute of Sports Science, 2012) included 3m sit, walk, and return, grip test, 30 second chair sit and stand, sit and reach, figure 8 walks, and 2 minute stationary march. Postural biomechanics variables included resting calcaneal stance position (RCSP), shoulder slope, pelvic slope, knee flexion angle, leg length difference, thoracic angle, and upper body slope. In statistical analysis, multiple regression was conducted by using stepwise selection method via SAS (version 9.2). Analysis for both men and women revealed significant relationships between physical fitness and age, upper body slope, knee flexion angle, leg length difference. Pelvic and thoracic angle were only related to figure 8 walking and sit and reach in women, while RCSP and shoulder slope had no relationship with any physical fitness variables.

Restoration of the Injured Fingertip with Eponychial Cutaneous Flap (손톱위 피부피판을 이용한 손톱형태 복원의 치험례)

  • Kim, Ho Kil;Kim, Cheol Hann;Kang, Sang Gyu;Jung, Sung Gyun;Kim, Yong Bae
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.763-766
    • /
    • 2005
  • The restoration of the fingernail is not simple in case of amputated distal fingertip which involved the pulp and nail. The nail should maintain a length of at least 2 mm from the eponychium for an adequate grip and decent appearance. Various methods to reconstruct the fingernail bed are available. The nail bed graft from amputated finger or great toe, and free onychocutaneous flap are commonly used. The nail bed of the injured tip tends to be atrophied, deformed and failed as a graft. And the great toe is often turned down as a donor. We have restored satisfactorily the nail beds of three injured finger tips with eponychial cutaneous flaps. The pulps were reconstructed with either a reverse dorsal digital island flap or free pulp graft. Repeated again. A mean follow- up was six months. The nail grew up to the average of 3.7 mm. All patients were satisfied with the length of the nail and met with good cosmetic results. An eponychial cutaneous flap is useful to restore the nail of the distal fingertip amputation. The procedure is relatively simple and morbidity is minimum.

Arterial or venous free flaps for volar tissue defects of the proximal interphalangeal joint: A comparison of surgical outcomes

  • Choi, Min Suk;Roh, Si Young;Koh, Sung Hoon;Kim, Jin Soo;Lee, Dong Chul;Lee, Kyung Jin;Hong, Min Ki
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.451-459
    • /
    • 2020
  • Background For volar soft tissue defects of the proximal interphalangeal (PIP) joint, free flaps are technically challenging, but have more esthetic and functional advantages than local or distant flaps. In this study, we compared the long-term surgical outcomes of arterial (hypothenar, thenar, or second toe plantar) and venous free flaps for volar defects of the PIP joint. Methods This was a single-center retrospective review of free flap coverage of volar defects between the distal interphalangeal and metacarpophalangeal joint from July 2010 to August 2019. Patients with severe crush injuries (degloving, tendon or bone defects, or comminuted/intra-articular fractures), thumb injuries, multiple-joint and finger injuries, dorsal soft tissue defects, and defects >6 cm in length were excluded from the study, as were those lost to follow-up within 6 months. Thirteen patients received arterial (hypothenar, thenar, or second toe plantar) free flaps and 12 received venous free flaps. Patients' age, follow-up period, PIP joint active range of motion (ROM), extension lag, grip-strength ratio of the injured to the uninjured hand, and Quick Disabilities of Arm, Shoulder & Hand (QuickDASH) score were compared between the groups. Results Arterial free flaps showed significantly higher PIP joint active ROM (P=0.043) and lower extension lag (P =0.035) than venous free flaps. The differences in flexion, grip strength, and QuickDASH scores were not statistically significant. Conclusions The surgical outcomes of arterial free flaps were superior to those of venous free flaps for volar defects of the PIP joint.

Changes of Impact Variables by the Change of Golf Club Length (골프 클럽에 따른 타격자세의 변화)

  • Sung, Rak-Joon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.181-189
    • /
    • 2005
  • To know the proper impact posture and changes for the various clubs, changes of impact variables according to the change of golf club length was investigated. Swing motions of three male low handicappers including a professional were taken using two high-speed video cameras. Four clubs iron 7, iron 5, iron 3 and driver (wood 1) were selected for this experiment. Three dimensional motion analysis techniques were used to get the kinematical variables. Mathcad and Kwon3D motion analysis program were used to analyze the position, distance and angle data in three dimensions. Major findings of this study were as follows. 1. Lateral position of the head remained more right side of the target up to 3.5cm compared to the setup as the length of the club increased. 2. Left shoulder raised up to 5cm and right shoulder lowered up to 2.5cm compared to setup. The shoulder line opened slightly (maximum 11 degrees) to the target line. 3. Forward lean angle of the trunk decreased up to 4 degrees (more erected) compared to setup. 4. Side lean angle of the trunk increased compared to setup and increased up to 16 degrees as the club length increased. 5. The pelvis moved to the target line direction horizontally and opened up to 31 degrees. Right hip moves laterally to the grip position at the setup. 6. Flexion of the left leg maintained almost constantly but the right leg flexed up to 11 degrees compared to setup. 7. Left arm is straightened but the right arm flexed about 20degrees compared to straight. 8. Center of the shoulders were in front of the knees and toes of the feet. 9. Hands moved to the left (8.7cm), forward (5.7cm) and upward (11.6cm) compared to the setup. This is because of the rotation of pelvis and shoulders. 10. Shaft angle to the ground was smaller than the lie angle of the clubs but it increased close to the lie of the clubs at impact.

Deformation Properties of Gold Bonding Wire for VLSI Packaging Applications (반도체 패키징용 Gold Bonding Wire의 변형특성 및 해석)

  • Kim K.;Hong S. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.05a
    • /
    • pp.250-253
    • /
    • 2001
  • Mechanical properties of gold bonding wire for VLSI packaging have been studied. The diameters of gold wires are about 20-30 micrometer and fracture loads are 8-20 gram force. The elastic modulus, yield strength, fracture strength and elongation properties have been evaluated by micro-tensile test method. This work discusses for an appropriate selection of micro-force testing system and grip design in mim testing. The best method to determine gauge length of wire and to measure tensile properties has been proposed. The mechanical properties such as strength and elastic modulus of current gold bonding wire are higher than pure those of gold wire.

  • PDF