• 제목/요약/키워드: Grid-Connection

Search Result 307, Processing Time 0.036 seconds

Analysis of International Trend on the Standard for Power System Connection of V2G System (V2G 시스템의 계통연계에 대한 국제 표준 동향 분석)

  • Lee, Soon-Jeong;Kim, Jun-Hyeok;Kim, Chul-Hwan;Kim, Gi-Hyun;Shin, Seong-Su
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1641-1642
    • /
    • 2015
  • Recently, the interest about Vehicle-to-Grid(V2G) system which can use the electric vehicles as generation sources or storage devices has rapidly increased. However, this technology does not use widely yet, and there is no clear standard or regulation for it. If electric vehicles are connected to the power system indiscreetly, it can cause problem to personnel safety and adverse effect on the power system. Therefore, it is important to analyze the related standards. In this paper, we introduce some international standard related with V2G system.

  • PDF

Study on electric equipment design for solution about Hapcheon No.2 Hydropower capacity increase and consequential grid-connection problem (합천 제2수력 발전기 용량증대에 따른 계통연계범위 이탈문제 해결을 위한 설비설계 방안 고찰)

  • Jeong, Hyo-Geun;Kim, Woo-Yong;Kang, Dong-Hyung;Choi, Hong-Yeol;Ham, Dong-Young;Jeong, Jun-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.219-220
    • /
    • 2015
  • 합천 제2수력 수차발전기 용량증대사업($1,200{\rightarrow}1,800kW$)에 따른 실시설계 시 계통연계 가능여부를 한전으로부터 확인한 결과, 해당 배전선로에 기 연계된 분산형전원에 의해 전압 상한치를 이미 상당히 초과하여 연계 불가한 것으로 회신받음에 따라 계통연계범위 이탈문제 해결 및 해당 배전선로 연계를 위한 위한 설비설계 방안을 고찰하였다.

  • PDF

A study on the variation of power factor by connection of the induction generator to the distribution line (배전선로에 유도발전기 연결시 역률 변동에 관한 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Kyung-Bae;Kim, Young-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1469-1470
    • /
    • 2015
  • Recently induction generator has been applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed how the power factor is changed according to the load increase or decrease in the distribution lines.

  • PDF

Transformer-less Type Grid-Connected PV Power Conditioning System (변압기 없는 계통연계형 PV PCS고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.551-554
    • /
    • 2002
  • This paper describes a new interactive inverter between a photovoltaic(PV) array and single-phase utility that avoid the bulky input (60Hz) transformer on the AC side. The interface employs a pwm boost converter on the DC side followed by a pwm current-forced single-phase rectifier for injecting the power from the PV array into the mains. The current waveform at the AC side remains sinusoidal and exactly in phase at all time. The circuit also has the advantage of requiring fewer switching device than high-frequency link system. This paper describes modeling of PV array and new system topology. Simulation results on the performance of the connection are also presented.

  • PDF

Flux Saturation Modeling of Matching Transformer for Dynamic Voltage Restore (동적전압보상기를 구성하기 위한 정합변압기의 자속포화현상 모델링)

  • Kim Wang-Rae;Kang Ho-Hyun;Jeon Hee-Jong;Han Woon-Dong;Oh Joong-Min
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.428-431
    • /
    • 2006
  • Matching transformer in Dynamic Voltage Compensator is needed for grid connection and isolation. Flux saturation in transformer will be occurred by voltage of transformer from inverter and DC offset voltage and flux saturation makes over current in transformer. In this paper, mathematical modeling of matching transformer is proposed for flux saturation simulation of Dynamic Voltage Compensator.

  • PDF

Demonstration Analysis of 3kW Grid Connected PV System (3kW급 계통연계형 태양광발전시스템 실증연구)

  • Choi Y.O.;Piao Z.G.;Jeong S.B.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.558-560
    • /
    • 2006
  • Solar cell converts sunlight into the electricity that one of the most versatile forms of energy. It has been developed and applied on residental electric power system by urbanized countries as a alternative energy source to overcome energy problem after oil shock. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter-connection and safety equipment will be summarized. Hence this paper discusses only points that might be useful for application.

  • PDF

Robust Direct Adaptive Current Controller for Grid-connection Inverter (계통연계형 인버터의 강인한 직접적응 전류제어 기법에 관한 연구)

  • Kim, Tae-Won;Park, Tae-Joon;Han, Mu-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.510-511
    • /
    • 2010
  • 본 논문은 계통연계형 인버터의 정현파 전류제어를 위한 직접 적응제어 기법을 제안한다. 기존의 계통연계형 인버터 전류제어기에 비해 고조파 성분 제거 능력이 우수하고 소프트웨어적으로 쉽게 구현할 수 있는 장점이 있다. LC필터의 L값의 변동에 의한 제어기 내부의 파라미터가 발산하는 문제를 Resetting기법을 적용하여 보완하였다. 본 논문에서 제안한 정현파 전류 적응제어기의 우수성을 시뮬레이션과 실험을 통해 검증하였다.

  • PDF

Development of the 4kW Photovoltaic Power Conditioning System (4kW 태양광 발전용 PCS 개발)

  • Lee, H.D.;Park, Y.H.;Jeon, S.B.;Kim, J.G.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.291-292
    • /
    • 2010
  • The main purpose of this study is to design and develop the grid connected 4kW photovoltatic PCS(Power Conditioning System) targeting for Japanese market. To make this task, the development of DC to DC converter, one phase inverter and EMI filters, and the research on connection between inverter and utility line are made. The developed 4kW PCS has fully carried out performance verifications and evaluation works and acquired the JET(Japan Electrical Safety & Environment Technology Laboratories) certification for safety and performance.

  • PDF

Study on the Transient Phenomenon Simulation of Wind Power Generation System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 풍력발전시스템의 과도현상 시뮬레이션에 관한 연구)

  • Han, Sang-Geun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.309-312
    • /
    • 2002
  • For the purpose of more effective simulation of the utility interactive WPGS(Wind Power Generation System) the SWRW (Simulation method for WPGS using Real Weather condition) is used in this paper, in which those of three topics for the WPGS simulation. user-friendly method, applicability to grid-connection and the utilization of the real weather conditions, are satisfied. The simulation of the WPGS using the real weather condition including components modeling of wind turbine system is achieved by introducing the interface method of a non-linear external parameter and FORTRAN using PSCAD/EMTDC. The simulations of steady-state and transient-state are performed effectively by the introduced simulation method. The generator output and current supplied into utility can be obtained by the steady-state simulation, and THD can be achieved by analyzing the results as well. The transient - state of the WPGS can be analyzed by the simulation results of over cut-out wind speed.

  • PDF

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF