• 제목/요약/키워드: Grid interface

검색결과 298건 처리시간 0.025초

공간 및 시간 정확도 향상을 위한 최적의 삽간영역 구성에 관한 연구 (A Study of Optimal Mesh Interface Region Generation to Improve Spatial and Temporal Accuracy)

  • 조금원
    • 한국전산유체공학회지
    • /
    • 제8권3호
    • /
    • pp.41-49
    • /
    • 2003
  • The spatial accuracy becomes first-order when second-order conservation schemes including the non-conservative interpolation in general Chimera method are used. To ensure the solution accuracy, the discontinuities must be located away from the overlapped regions, and the length of overlapped region also must be proportional to the grid spacing. In this paper, a proposed method, cut-paste algorithm, is used to satisfy above constraints. The cut-paste algorithm can generate the optimal mesh inteface region automatically, To validate the spatial and temporal accuracy due to the non-conservative interpolation, inviscid and viscous problems are tested.

병렬로 나열된 두개의 원형실린더 주위 층류의 후류 특성 (Characteristics of Laminar Wake Around Two-Circular Cylinder in Side-by-Side Array)

  • 이상범;박종천
    • 한국해양공학회지
    • /
    • 제20권5호
    • /
    • pp.15-22
    • /
    • 2006
  • A finite-volume method using multi-block grid technique has been developed in order to investigate the flow field around multi-body. Here the matching grids are used at the interface between blocks and the boundary conditions are imposed there to exchange physical values across the interface. For the test problems, the laminar viscous flaw around one-and two-cylinder are simulated and the results are compared with experiments and other numerical results.

Review of Multifunctional Inverter Topologies and Control Schemes Used in Distributed Generation Systems

  • Teke, Ahmet;Latran, Mohammad Barghi
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.324-340
    • /
    • 2014
  • Recent developments in power electronics technology have spurred interest in the use of renewable energy sources as distributed generation (DG) generators. The key component in DG generators is a grid-connected inverter that serves as an effective interface between the renewable energy source and the utility grid. The multifunctional inverter (MFI) is special type of grid-connected inverter that has elicited much attention in recent years. MFIs not only generate power for DGs but also provide increased functionality through improved power quality and voltage and reactive power support; thus, the capability of the auxiliary service for the utility grid is improved. This paper presents a comprehensive review of the various MFI system configurations for single-phase (two-wire) and three-phase (three- or four-wire) systems and control strategies for the compensation of different power quality problems. The advances in practical applications and recent research on MFIs are presented through a review of nearly 200 papers.

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

LOCALLY ENRICHED QUADTREE GRID NUMERICAL MODEL FOR NEARSHORE CIRCULATION IN THE SURF ZONE

  • Park, Koo-Yong
    • Water Engineering Research
    • /
    • 제1권3호
    • /
    • pp.187-197
    • /
    • 2000
  • This paper describes an adaptive quadtree-based 2DH wave-current interaction model which is able to predict wave breaking, shoaling, refraction, diffraction, wave-current interaction, set-up and set-down, mixing processes (turbulent diffusion), bottom frictional effects, and movement of the land-water interface at the shoreline. The wave period-and depth-averaged governing equations are discretised explictly by means of an Adams-Bashforth second-order finite difference technaique on adaptive hierarchical staggered quadtree grids. Grid adaptation is achieved through seeding points distributed according to flow criteria(e.g. local current gradients). Results are presented for nearshore circulation at a sinusoidal beach. Enrichment permits refined modelling of important localised flow features.

  • PDF

Implementation of Intelligent Home Network and u-Healthcare System based on Smart-Grid

  • Kim, Tae Yeun;Bae, Sang Hyun
    • 통합자연과학논문집
    • /
    • 제9권3호
    • /
    • pp.199-205
    • /
    • 2016
  • In this paper, we established ZIGBEE home network and combined smart-grid and u-Healthcare system. We assisted for amount of electricity management of household by interlocking home devices of wireless sensor, PLC modem, DCU and realized smart grid and u-Healthcare at the same time by verifying body heat, pulse, blood pressure change and proceeded living body signal by using SVM algorithm and variety of ZIGBEE network channel and enabled it to check real-time through IHD which is developed by user interface. In addition, we minimized the rate of energy consumption of each sensor node when living body signal is processed and realized Query Processor which is able to optimize accuracy and speed of query. We were able to check the result that is accuracy of classification 0.848 which is less accounting for average 17.9% of storage more than the real input data by using Mjoin, multiple query process and SVM algorithm.

OAuth 기반의 대리 인증서 위임 서비스 (OAuth based Proxy Delegation Service)

  • 허대영;황선태
    • 인터넷정보학회논문지
    • /
    • 제13권6호
    • /
    • pp.55-62
    • /
    • 2012
  • 그리드 환경에서 그리드 서비스를 웹 인터페이스 및 웹 서비스로 제공하기 위해 웹 표준 기술에 기반을 둔 그리드-웹 애플리케이션이 증가하고 있다. 그러나 웹 표준 보안 구조에서 위임 인증 방법의 부재로 웹 애플리케이션에 그리드 보안 시스템 GSI를 통합하는 것은 매우 어렵다. 이를 해결하기 위해서는 온라인 자격증명 저장 서비스를 이용하여 웹 애플리케이션에서 그리드 자격증명을 사용할 수 있도록 해야 한다. 본 논문에서는 그리드-웹 애플리케이션과 사용자 간의 상호 신뢰를 전제로 하는 온라인 자격증명 저장 서비스인 MyProxy를 사용하는 방법의 문제점을 분석하고, 상호 신뢰를 바탕으로 하지 않는 그리드 자격증명 위임 서비스를 제안한다. 이 서비스의 자격증명 교환 프로토콜은 OAuth에 X.509 인증 위임 절차를 추가한 것이다. 이 위임 서비스는 그리드-웹 애플리케이션에게 단일 로그온을 제공하고, 하나 이상의 그리드 자격증명을 위임하고 획득할 수 있는 보안 방법을 제공한다.

2차원 압축공기-물의 압축성 이상 유동 수치 해석 (Numerical Analysis for Two-Dimensional Compressible and Two-Phase Flow Fields of Air-Water in Eulerian Grid Framework)

  • 박찬욱;이승수
    • 대한기계학회논문집B
    • /
    • 제32권6호
    • /
    • pp.429-445
    • /
    • 2008
  • Two-phase compressible flow fields of air-water are investigated numerically in the fixed Eulerian grid framework. The phase interface is captured via volume fractions of each phase. A way to model two phase compressible flows as a single phase one is found based on an equivalent equation of states of Tait's type for a multiphase cell. The equivalent single phase field is discretized using the Roe‘s approximate Riemann solver. Two approaches are tried to suppress the pressure oscillation phenomena at the phase interface, a passive advection of volume fraction and a direct pressure relaxation with the compressible form of volume fraction equation. The direct pressure equalizing method suppresses pressure oscillation successfully and generates sharp discontinuities, transmitting and reflecting acoustic waves naturally at the phase interface. In discretizing the compressible form of volume fraction equation, phase interfaces are geometrically reconstructed to minimize the numerical diffusion of volume fraction and relevant variables. The motion of a projectile in a water-filled tube which is fired by the release of highly pressurized air is simulated presuming the flow field as a two dimensional one, and several design factors affecting the projectile movement are investigated.

순시직전류(瞬時直電流) 추종제어형(追從制御形) Inverter의 태양광발전(太陽光發電) 시스템에의 응용(應用) (Application of Instantaneous sinusoidal current tracking control inverter for photovoltaic system)

  • 유권종;정명웅;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.372-375
    • /
    • 1990
  • A sinusoidal PWM type inverter using 1GBT and a new instantaneous current tracking control stategy is described. Its utilization as an interface for a grid-connected photovoltaic system with maxmum power tracking capability is explaned, and competer simulation along with waveforms are discussed. Finally, experimental results are analysed by state space avarge method to actual grid-connected systems.

  • PDF