• 제목/요약/키워드: Grid fault

검색결과 358건 처리시간 0.03초

22.9kV 지중선로용 한류기 한전 실계통 시범적용 (Application of Fault Current Limiter in 22.9kV KEPCO power distribution line)

  • 김민지;박경원;안길영;김영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

안티아일랜딩 기능을 적용한 전기자동차 충전계통 연계 스마트그리드 모니터링 시스템 개발 (Development of a Smart Grid Monitoring System with Anti-Islanding Function for Electric Vehicle Charging)

  • 노선희;신범식;이경중;기영훈;안현식
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 논문에서는 무선 센서 네트워크를 활용하여 스마트그리드와 전기자동차의 충전 시스템 연계과정을 효과적으로 파악하고, 안티아일랜딩 기능을 적용하여 전기자동차 충전계통과 연계된 스마트그리드 모니터링 시스템을 제안한다. 스마트그리드 모니터링 시스템은 지그비(ZigBee)통신을 통해 무선으로 전력 모니터링 데이터를 수신하며, 별도의 물리적 연결 없이 원격 제어를 통해 전기자동차의 충전제어가 가능하다. 또한, 그리드 내 독립전원에 아일랜딩 현상이 발생하면, 아일랜딩 현상이 발생한 독립전원을 즉시 감지하여 차단하고 다른 독립전원으로 대체하여 그리드의 안정적인 운용을 하도록 하며, 실험을 통하여 스마트그리드 모니터링 시스템의 성능을 확인한다.

PQR 순시전력이론에 의한 Dynamic Voltage Restorer의 제어기 설계 I -기준전압 파형의 발생 (Controller Design for Dynamic Voltage Restorers by use of PQR Power Theory I - Reference Wave Generation)

  • 김효성;이상준;설승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.398-403
    • /
    • 2003
  • Dynamic Voltage Restorers (DVR)s are known as the best effective and economic means to compensate for voltage sags and swells [1]-[11]. This paper proposes a novel method to generate reference voltages synchronized with the grid whether the line voltages are distorted by a fault or not. The proposed reference wave generator (RWC) looks for the original wave forms from the corrupted line voltages and synthesizes the expected positive sequence reference waves for DVRs. There is no transient problem on the generated reference waves when the line voltages are distorted by the fault.

  • PDF

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

송.배전급 저항형 초전도 한류기 설계 요소 검출을 위한 고온 초전도 선재의 특성 연구 (Experimental Study on the High Temperature Superconductor for Investigated Design Factors of Distribution and Transmission Level Resistive Type Superconductor Fault Current Limiter)

  • 나진배;장재영;조현철;황영진;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.10-13
    • /
    • 2011
  • The power demand is steadily increasing due to rapidly develop of industrial field. The ratio of prospected increment of power consumption is over 2.2 % per year from 2007 to 2020 year. The superconducting fault current limiters(SFCLs) should be suggested to be one of promising machines to protect power grid. Four basis tests such as resistivity, short-circuit tests, ac losses and recovery time were investigated according to various reached maximum temperature, operating temperature. This paper deals with investigation of the various commercial high temperature superconductor for applying resistive type SFCLs.

유도전동기 부하 고려 시 저전압 부하차단을 이용한 전력계통 안정도 향상 방안 (Using the Under Voltage Load Shedding for Stability Enhancement of Power Systems Considering Induction Motor Load)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.1-6
    • /
    • 2016
  • Recently, proportion of the induction motor load is gradually increased. When a contingency in the power systems, it has been discovered phenomenon that the voltage is delayed recover caused mechanical characteristics of the induction motor load. It can be a serious impact on the voltage stability of the power system considering induction motor load. The scheme to mitigate this phenomenon tripping off the motors to prevent voltage drop and delayed voltage recovery on the load demand side. Fault induced delayed voltage recovery phenomenon is caused by stalling of small induction motor load in transmission level contingencies. In this paper, fault induced delayed voltage recovery phenomenon mitigation method implementation under voltage load shedding on the korean power system considering induction motor load.

PQR 순시전력이론에 의한 동적전압보상기의 기준파 발생기 (The Reference Wave Generator for Dynamic Voltage Restorers by use of PQR Instantaneous Power Theory)

  • 김효성;이상준;설승기
    • 전력전자학회논문지
    • /
    • 제8권5호
    • /
    • pp.435-441
    • /
    • 2003
  • 순시전압강하보상기 (DVR)는 순시전압강하 및 상승을 보상하기 위한 가장 효과적이고 경제적인 수단으로 알려져 있다. 본 논문은 계통의 전압이 사고에 의해서 심하게 왜곡되는 경우에서도 계통과 동기된 정현적인 기준파를 생성하는 방법을 제시한다. 제안된 기준파발생기 (RWG)는 사고로 왜곡된 전압으로부터 원래의 정현적인 파형을 추출하고 정상 성분만의 전압을 합성하여 DVR의 제어에 사용하도록 한다. 전윈 전압의 사고 순간에도 RWG는 과도적인 문제가 없는 안정된 정현 파형을 출력한다.

Grid Code의 Fault Ride Through와 독립부하전압 보상을 위한 간접전류제어 계통연계 인버터 (Utility Interactive Inverter using Indirect Current Control for Fault Ride Through and Voltage Compensation)

  • 윤선재;오형민;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.207-209
    • /
    • 2010
  • 연료전지 시스템의 경우 계통에 Sag 및 Swell 같은 이상이 발생하더라도 계통과 분리되기 전 MBOP등 독립부하에는 안정적인 전원을 공급하는 것이 중요하다. 기존의 직접전류제어방식으로는 계통이상 시 전압을 제어할 수 없으므로 독립부하에 계통이상전압이 그대로 걸리게 된다. 본 논문에서는 계통에 Sag 및 Swell 같은 상황이 발생하더라도 무효전류를 제어하여 자체 부하전압을 보상할 수 있는 간접전류제어 전압보상기법을 이용한 계통 연계형 인버터의 동작을 분석하고 이에 맞는 소자 및 새로운 LCL필터 설계방법을 제안한다.

  • PDF

적응적 자가 튜닝 서포트벡터머신을 이용한 베어링 고장 진단 (Bearing Fault Diagnosis using Adaptive Self-Tuning Support Vector Machine)

  • 김재영;김종면;최병근;손석만
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2016년도 제53차 동계학술대회논문집 24권1호
    • /
    • pp.19-20
    • /
    • 2016
  • 본 논문에서는 서포트 벡터 머신 (SVM)의 분류 성능에 영향을 주는 인수인 C와 ${\sigma}$ 값을 적응적으로 최적화할 수 있는 적응적 자가튜닝 SVM을 이용한 베어링의 상태 진단 방법을 제안한다. SVM의 각 인수의 변화에 따른 베어링 상태 진단의 성능 변화 패턴을 분석하여 적합한 인수를 적응적으로 찾을 수 있는 방법을 제안하고, 제안한 방법의 우수성을 검증하기 위해 실제 베어링 신호를 이용하여 기존방법인 격자탐색과의 성능을 비교하였다.

  • PDF

루프 배전계통에서 Agent를 이용한 보호협조 및 자동정정 방법에 관한 연구 (A Study on the Protective Coordination and Automatic Setting Method using Agents in Distribution System with Loop)

  • 진영택;이승재;최면송;임성일;김태완
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1107-1114
    • /
    • 2012
  • In this paper, we propose protective coordination and automatic setting method using agents for distribution system with loop. The proposed protection scheme adopts an agent technology assuming communication among protection agents and auto-switch agents. Having exchanged fault-related information with each other, protection agents and auto-switch agents perform the primary and backup protection and fault section isolation, respectively. this proposed scheme using agents for distribution system with loop is implemented by matlab. Because of the various configuration of distribution system, It's difficult to find cooperative agents for each agent. This paper develops a program to automatically set the cooperative route for the agents.