• Title/Summary/Keyword: Grid current

Search Result 1,327, Processing Time 0.035 seconds

Grid Current Control Scheme at Thee-Phase Grid-Connected Inverter Under Unbalanced and Distorted Grid Voltage Conditions (계통전압 왜곡 및 불평형시 3상 계통연계인버터의 계통전류제어 기법)

  • Tran, Thanh-Vu;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1560-1565
    • /
    • 2013
  • This paper proposes the control method for compensating for unbalanced grid current and reducing a total harmonic distortion (THD) of the grid current at the three-phase grid-connected inverter systems under unbalancd and distorted grid voltage conditions. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for a minimum point of THD. Both the gain and angle of a compensation voltage at the minimum point of THD of the grid current are derived. The negative-sequence components in the three-phase unbalanced grid voltage are cancelled in order to achieve the balanced grid current. The simulation and experimental results show the validity of the proposed control methods.

Research on a Multi-Objective Control Strategy for Current-source PWM Rectifiers under Unbalanced and Harmonic Grid Voltage Conditions

  • Geng, Yi-Wen;Liu, Hai-Wei;Deng, Ren-Xiong;Tian, Fang-Fang;Bai, Hao-Feng;Wang, Kai
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.171-184
    • /
    • 2018
  • Unbalanced and distorted grid voltages cause the grid side current of a current source PWM rectifier to be heavily distorted. They can also cause the DC-link current to fluctuate with a huge amplitude. In order to enhance the performance of a current-source PWM rectifier under unbalanced and harmonic grid voltage conditions, a mathematical model of a current-source PWM rectifier is established and a flexible multi-objective control strategy is proposed to control the DC-link current and grid-current. The fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic components of the grid voltage are first separated with the proposed control strategy. The grid current reference are optimized based on three objectives: 1) sinusoidal and symmetrical grid current, 2) sinusoidal grid current and elimination of the DC-current $2^{nd}$ order fluctuations, and 3) elimination of the DC-current $2^{nd}$ and $6^{th}$ order fluctuations. To avoid separation of the grid current components, a multi-frequency proportional-resonant controller is applied to control the fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic current. Finally, experimental results verify the effectiveness of proposed control strategy.

Analysis and Control of Neutral Point Current Deviation in Grid Tied 3-Level NPC Converter under Various Grid Unbalanced Conditions (다양한 불평형 계통 상황에서 계통 연계형 3-레벨 NPC 컨버터의 중성점 전류 변동에 대한 해석 및 제어)

  • Choi, Jaehoon;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.385-393
    • /
    • 2020
  • This study introduces an analysis and control method for the variation of neutral point current in a grid-tied three-level neutral point clamped (NPC) converter under various grid imbalance operating conditions. Various fault cases with unbalanced amplitude and phase are systematically categorized and described using a unified metric called the imbalance factor. The fundamental component of neutral point current is generated under grid imbalance cases. The pattern and behavior of this fundamental component of neutral point current highly depend on the imbalance factor regardless of the particular type of grid fault cases. The control scheme for regulating the negative sequential component of AC input current effectively reduces the size of the fundamental component of neutral point current under a wide range of grid imbalance cases. The control scheme will enable a grid-tied three-level NPC converter to operate reliably and stably under various types of grid faults.

Current Harmonics Rejection and Improvement of Inverter-Side Current Control for the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1672-1682
    • /
    • 2017
  • For grid-connected LCL-filtered inverters, the inverter-side current can be used as the control object with one current sensor for both LCL resonance damping and over-current protection, while the grid-voltage feedforward or harmonic resonant compensator is used for suppressing low-order grid current harmonics. However, it was found that the grid current harmonics were high and often beyond the standard limitations with this control. The limitations of the inverter-side current control in suppressing low-order grid current harmonics are analyzed through inverter output impedance modeling. No matter which compensator is used, the maximum magnitudes of the inverter output impedance at lower frequencies are closely related to the LCL parameters and are decreased by increasing the control delay. Then, to improve the grid current quality without complicating the control or design, this study proposes designing the filter capacitance considering the current harmonic constraint and using a PWM mode with a short control delay. Test results have confirmed the limitation and verified the performance of the improved approaches.

Control Method for Reducing the THD of Grid Current of Three-Phase Grid-Connected Inverters Under Distorted Grid Voltages

  • Tran, Thanh-Vu;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.712-718
    • /
    • 2013
  • This paper proposes a control method for reducing the total harmonic distortion (THD) of the grid current of three-phase grid-connected inverter systems when the grid voltage is distorted. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for the minimum point of the THD. Both the gain and angle of the compensation voltage at the minimum point of the THD of the grid current are derived with the variation of cut-off frequencies of the hardware LPF. Simulation and experimental results show the validity of the proposed control methods.

Improved Deadbeat Current Controller with a Repetitive-Control-Based Observer for PWM Rectifiers

  • Gao, Jilei;Zheng, Trillion Q.;Lin, Fei
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 2011
  • The stability of PWM rectifiers with a deadbeat current controller is seriously influenced by computation time delays and low-pass filters inserted into the current-sampling circuit. Predictive current control is often adopted to solve this problem. However, grid current predictive precision is affected by many factors such as grid voltage estimated errors, plant model mismatches, dead time and so on. In addition, the predictive current error aggravates the grid current distortion. To improve the grid current predictive precision, an improved deadbeat current controller with a repetitive-control-based observer to predict the grid current is proposed in this paper. The design principle of the proposed observer is given and its stability is discussed. The predictive performance of the observer is also analyzed in the frequency domain. It is shown that the grid predictive error can be decreased with the proposed method in the related bode diagrams. Experimental results show that the proposed method can minimize the current predictive error, improve the current loop robustness and reduce the grid current THD of PWM rectifiers.

The Compensation of the Grid Current Distortion caused by the Grid Voltage Unbalance and Distortion for 3-Phase Bi-Directional DC to AC Inverter (3상 양방향 인버터의 계통전압 불평형 및 왜곡에 의한 계통전류 보상)

  • Yang, Seung-Dae;Kim, Seung-Min;Choi, Ju-Yeop;Choy, Ick;Song, Seung-Ho;Lee, Sang-Cheol;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.228-234
    • /
    • 2012
  • This paper presents the algorithm of the compensation of the grid current distortion caused by the grid voltage unbalance and distortion in 3-phase bi-directional DC to AC inverter. Usually 3-phase grid system has unbalance and distortion because of connecting 1-phase and non-linear load with 3-phase load using same input node. Controlling 3-phase inverter by general method under the unbalanced and distorted grid voltage, the grid current has distortion. This distortion of the grid current cause the grid voltage distortion again. So, it need to control the grid current balanced and non-distorted, even the grid voltage gets unbalanced and distorted. There are some complex method to compensate the gird current distortion. it sugest simple method to solve the problem. PSIM simulation is used to validate the proposed algorithm.

Grid Voltage-sensorless Current Control of LCL-filtered Grid-connected Inverter based on Gradient Steepest Descent Observer

  • Tran, Thuy Vi;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.380-381
    • /
    • 2019
  • This paper presents a grid voltage-sensorless current control design for an LCL-filtered grid-connected inverter with the purpose of enhancing the reliability and reducing the total cost of system. A disturbance observer based on the gradient steepest descent method is adopted to estimate the grid voltages with high accuracy and light computational burden even under distorted grid conditions. The grid fundamental components are effectively extracted from the estimated gird voltages by means of a least-squares algorithm to facilitate the synchronization process without using the conventional phase-locked loop. Finally, the estimated states of inverter system obtained by a discrete current-type full state observer are utilized in the state feedback current controller to realize a stable voltage-sensorless current control scheme. The effectiveness of the proposed scheme is validated through the simulation results.

  • PDF

Stability Analysis of Grid-Connected Inverters with an LCL Filter Considering Grid Impedance

  • Li, Xiao-Qiang;Wu, Xiao-Jie;Geng, Yi-Wen;Zhang, Qi
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.896-908
    • /
    • 2013
  • Under high grid impedance conditions, it is difficult to guarantee the stability of grid-connected inverters with an LCL filter designed based on ideal grid conditions. In this paper, the theoretical basis for output impedance calculation is introduced. Based on the small-signal model, the d-d channel closed-loop output impedance models adopting the converter-side current control method and the grid-side current control method are derived, respectively. Specifically, this paper shows how to simplify the stability analysis which is usually complemented based on the generalized Nyquist stability criterion (GNC). The stability of each current-controlled grid-connected system is analyzed via the proposed simplified method. Moreover, the influence of the LCL parameters on the stability margin of grid-connected inverter controlled with converter-side current is studied. It is shown that the stability of grid-connected systems is fully determined by the d-d channel output admittance of the grid-connected inverter and the inductive component of the grid impedance. Experimental results validate the proposed theoretical stability analysis.

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.383-391
    • /
    • 2014
  • For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.