• Title/Summary/Keyword: Grid Unit

Search Result 282, Processing Time 0.039 seconds

FDTD Analysis of the Absorption Characteristics for Grid Ferrite Electromagnetic Wave Absorber (FDTD를 이용한 격자형 페라이트 전파흡수체 특성 해석)

  • 이재용;정연춘;명노훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.483-490
    • /
    • 1998
  • The reflectivity of a grid ferrite electromagnetic wave absorber is analyzed using finite difference time domain (FDTD) method, which is usually used in anechoic chambers for EMI / EMS test. The frequency dispersive characteristics of ferrite medium and its boundary condition are modeled using magnetic flux in addition to E- and H-fields. By applying Floquets theorem, FDTD analysis of the grid ferrite absorber with periodic infinite array is simplified as a unit cell problem. The method of homogenization which is mainly utilized in the calculation of absorber reflectivity as a low frequency technique takes only into account volume fraction of the unit cell of the absorber except for the structure of medium geometry. However, the presented method in this paper can analyze the geometry effect of the unit cell with its medium characteristics up to high frequency region.

  • PDF

Application Contents Deploy System based on workflow process a unit based for collaboration in Grid Environment (그리드 환경에서 협업을 위한 워크플로우 프로세스 단위 기반의 애플리케이션 컨텐츠 배포 시스템)

  • Moon, Seok-Jae;Heo, Hyuk;Choi, Young-Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.172-182
    • /
    • 2008
  • Application Contents of based on a workflow process unit in grid system is a practical work to solve the problem. To construct cooperation environment is very important because the contents are deployed and executed. And the most of cooperation is executed by workflow. Globus toolkit is the middleware for cooperation process in grid environment. However the middleware only provides basic services for constructing grid, not workflow that can provides cooperation, job scheduling, application contents management. Also Globus toolkit is suitable for huge gird community but small size pc based grid community. Therefore, this paper proposes the efficient application contents deployment system for small sizes cooperation. This system supports efficient cooperation environment with Application contents deployment and resource management provided in grid community. Also it presents information and association relation among application contents with association dictionary among application contents based on workflow process unit, and utilizes this as information for application contents deployment.

Communication Methodology Between Digital FRTUs Based on Wi-Fi Communication for the Smart Grid of Distribution System Area (스마트 그리드 배전 시스템을 위한 와이파이 통신에 기반한 디지털 FRTU간 통신 방법론 기초연구)

  • Woo-Kyung, Jin;Ji-Hyeon, Youn;Min-Seok, Choi;Jae-Hyun, Lee;Birek, Ohgan;Yun-Seok, Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1113-1120
    • /
    • 2022
  • In this paper, a communication methodology for the digital FRTU(: Feeder Remote Terminal Unit) required by the smart grid distribution system was studied. The digital FRTU consists of a fault handling unit and a communication unit. The fault handling unit transmits fault information to the communication unit in case of a failure, and the communication unit is designed to autonomously determine the fault section through two-way communication between surrounding digital FRTUs. For performance verification, a performance verification system consisting of 3 line sections based on 3 digital FRTUs was constructed to enable fault simulation for various failure scenarios. Various fault cases including one phase ground fault, line-to-line short-circuit fault, and three-phase short-circuit fault were experimentally simulated on the established performance verification system, and the validity of the developed methodology was confirmed by proving the accurate fault section inference results for each fault simulation case.

The Grid Type Quadratic Assignment Problem Algorithm (그리드형 2차 할당문제 알고리즘)

  • Lee, Sang-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.4
    • /
    • pp.91-99
    • /
    • 2014
  • TThis paper suggests an heuristic polynomial time algorithm to solve the optimal solution for QAP (quadratic assignment problem). While Hungarian algorithm is most commonly used for a linear assignment, there is no polynomial time algorithm for the QAP. The proposed algorithm derives a grid type layout among unit distances of a distance matrix. And, we apply max-flow/min-distance approach to assign this grid type layout in such a descending order way that the largest flow is matched to the smallest unit distance from flow matrix. Evidences from implementation results of the proposed algorithm on various numerical grid type QAP examples show that a solution to the QAP could be obtained by a polynomial algorithm.

Grid Unit Based Analysis of Climate Change Driven Disaster Vulnerability in Urban Area (격자단위 분석기법을 적용한 도시 기후변화 재해취약성분석)

  • Hong, Jeajoo;Lim, HoJong;Ham, YoungHan;Lee, ByoungJae
    • Spatial Information Research
    • /
    • v.23 no.6
    • /
    • pp.67-75
    • /
    • 2015
  • Today, because human settlements are concentrated into urban area, urban planning and management technique considering the complexity, diversity, and advanced situations of urban living space is being requested. Especially, to effectively respond to large and diverse climate change driven disaster, it is necessary to develop urban planning technique including land use, infrastructure planning based on disaster vulnerability analysis. However, because current urban climate change disaster vulnerability analysis system(UC-VAS) is using census output area as spatial analysis unit, it is difficult to utilize the analysis results for specific urban planning. Instead, this study applies the grid manner to two study areas. The analysis results show that it can generate more detailed results and it can be used for detailed zoning decision by comparing with areal photos. Furthermore, by describing the limitation of the grid manner and providing professional way to secure additional scientific character and objectivity of the future urban climate change disaster vulnerability analysis system, it is expected that this study contributes to the effectiveness of system management.

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

Observer-based Voltage Sensorless Control Scheme for an LCL-filtered Grid-connected Inverter

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.266-267
    • /
    • 2017
  • To synchronize the distributed generation (DG) unit with the grid, the voltage sensors are generally employed to obtain the grid phase angle. This paper presents an observer-based voltage sensorless control scheme for a three-phase inverter connected to the grid through an LCL filter. The proposed control scheme consists of an augmented state observer and a feedback controller. The augmented state observer is used to estimate the grid voltages and states of the inverter system, which are then employed to determine the grid voltage angle and to construct the feedback controller. As a result of using the observer, only the grid current sensors are required to accomplish the control scheme. The simulation results are given to prove the validity of the proposed control scheme.

  • PDF

A Scheme on Energy Efficiency Through the Convergence of Micro-grid and Small Hydro Energy (마이크로그리드와 소수력 에너지의 융합을 통한 에너지 효율화 기법)

  • Kang, Bo-Seon;Lee, Keun-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • As smart grid techniques developed, public attention is concentrating on energy efficiency. So it is necessary to study on new renewable energy in order to manage the energy within micro grid consisting smart grid. Among them, small hydro energy has the advantage of being installable anywhere depending the amount of water used by the users within micro grid. This study examines if the measured value is appropriate for small hydro power generation by measuring generation quantity and operation rate of generator based on the sewage flow used by apartments and multi-unit dwellings where those users live. Some appropriate apartments and multi-unit dwellings generate electricity with small hydro generator using sewage as potential energy. This study intends to suggest more effective management by introducing energy management system and electricity storage device of micro grid.

The Testbed System for Crisis Management System of the Power Grid Using Satellite Communication Network (위성망을 이용한 파워 그리드 위기관리 시스템의 테스트베드 구현)

  • Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.86-95
    • /
    • 2011
  • In this paper, we propose a testbed system for the crisis management system of the power grid(CMS-PG) using satellite communication network. For the verification of CMS-PG, the proposed system composed of the simulator of satellite communication network and the simulator of phase measurement unit. Proposed satellite communication simulator can evaluate the delay and the robustness of the communication according to the rainfall and the humidity of local site. And the proposed simulator can calculates the voltage stability by hardware implementation using FPGA. Using the proposed testbed system, we adapted its function of crisis management system for the conventional power grid.

A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment (배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Kim, Jae-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.