• Title/Summary/Keyword: Grid Test

Search Result 951, Processing Time 0.034 seconds

Design & Implementation of a Multimedia communication Grid (멀티미디어 통신 그리드의 설계 및 구현)

  • Kim, Il-Min
    • Journal of Digital Contents Society
    • /
    • v.8 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Grid is a distributed computing model for next to the WWW computing model. Java language is developed for distributed computing and is being commonly used for WWW applications. Java can also be used for designing and implementing Grid systems. We introduced the basic concepts of Grid and implemented a new computing grid system. We test proper distributed applications on the multimedia grid system and analyzed the execution results. The execution results showed that the grid performance was much better than the legacy systems.

  • PDF

Event Detection on Motion Activities Using a Dynamic Grid

  • Preechasuk, Jitdumrong;Piamsa-nga, Punpiti
    • Journal of Information Processing Systems
    • /
    • v.11 no.4
    • /
    • pp.538-555
    • /
    • 2015
  • Event detection based on using features from a static grid can give poor results from the viewpoint of two main aspects: the position of the camera and the position of the event that is occurring in the scene. The former causes problems when training and test events are at different distances from the camera to the actual position of the event. The latter can be a source of problems when training events take place in any position in the scene, and the test events take place in a position different from the training events. Both issues degrade the accuracy of the static grid method. Therefore, this work proposes a method called a dynamic grid for event detection, which can tackle both aspects of the problem. In our experiment, we used the dynamic grid method to detect four types of event patterns: implosion, explosion, two-way, and one-way using a Multimedia Analysis and Discovery (MAD) pedestrian dataset. The experimental results show that the proposed method can detect the four types of event patterns with high accuracy. Additionally, the performance of the proposed method is better than the static grid method and the proposed method achieves higher accuracy than the previous method regarding the aforementioned aspects.

The Strap Vibration Characteristics in $5{\times}5$ Grid Exposed to Axial Flow (축방향 유속에 노출된 $5{\times}5$ 지지격자 스트랩의 진동특성)

  • Kim, Kyoung-Hong;Park, Nam-Gyu;Kim, Kyoung-Ju;Suh, Jung-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.911-916
    • /
    • 2012
  • It is important to identify dynamic characteristics of nuclear fuel components. Since the fuel always exposed to turbulent flow, the dynamic contact between grids and rods is one of the fuel failure modes. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring support are placed in the limited space. The strap in a cell has single spring and double dimples and this paper focuses on investigation of the grid strap(Test Fuel Strap, TFS) vibration in one cell. To identify the grid strap vibration, modal analysis of the strap is performed using Finite Element Method (FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in INvestigation of Flow INduced vIbraTion(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.

  • PDF

Electrohydrodynamic 젯 프린팅 시스템을 이용한 Graphene 기반 Graphene/Ag-grid 하이브리드 투명 전극의 특성연구

  • Park, Ha-Nul;Jo, Da-Yeong;Lee, Hye-Min;Seo, Gi-Won;Kim, Hyo-Jung;Lee, Yeong-U;Kim, Ji-Hun;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.185.1-185.1
    • /
    • 2014
  • 본 연구에서는 Electrohydrodynamic (EHD) 젯 프린팅 시스템을 이용하여 graphene이 올려져 있는 유연성 있는 PET 기판 위에 Ag 용액을 그리드로 간격에 따라 타진하였다. Ag 그리드 간격을 200 um, 300 um, 400 um, 500 um로 증가시켰으며, 이때 UV/Vis spectrometry, four-point probe를 이용하여 전기적, 광학적 특성을 분석하였다. Graphene/Ag-grid 하이브리드 투명전극은 그리드 간격 400 um에서 21Ohm/sq.의 면저항과 550 nm에서 84.08%의 투과도를 확인하였다. 또한, graphene/Ag-grid 하이브리드 투명전극의 기계적 응력에 따른 전기적 안정성을 알아보기 위해 radius에 따른 bending, fatigue test와 twist bending, rolling test를 진행하였다. Fatigue bending은 speed 30 mm/s, outer bending radius 20 mm, inner bending radius 22.5 mm로 bending test를 5000번 진행하였으며, twist bending, rolling test를 각각 10000번 진행하였다. 이 결과를 통해 bending-release cycle 조건에서도 초기저항 대비 5% 이내의 매우 우수한 전기적 안정성을 나타냄을 확인하였다. 이러한 graphene/Ag-grid 하이브리드 투명전극의 우수한 특성을 얻음으로써, graphene 박막의 플렉시블 투명전극으로서의 적용가능성을 타진할 수 있었다.

  • PDF

A Source Code Cross-site Scripting Vulnerability Detection Method

  • Mu Chen;Lu Chen;Zhipeng Shao;Zaojian Dai;Nige Li;Xingjie Huang;Qian Dang;Xinjian Zhao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.6
    • /
    • pp.1689-1705
    • /
    • 2023
  • To deal with the potential XSS vulnerabilities in the source code of the power communication network, an XSS vulnerability detection method combining the static analysis method with the dynamic testing method is proposed. The static analysis method aims to analyze the structure and content of the source code. We construct a set of feature expressions to match malignant content and set a "variable conversion" method to analyze the data flow of the code that implements interactive functions. The static analysis method explores the vulnerabilities existing in the source code structure and code content. Dynamic testing aims to simulate network attacks to reflect whether there are vulnerabilities in web pages. We construct many attack vectors and implemented the test in the Selenium tool. Due to the combination of the two analysis methods, XSS vulnerability discovery research could be conducted from two aspects: "white-box testing" and "black-box testing". Tests show that this method can effectively detect XSS vulnerabilities in the source code of the power communication network.

Reliability Test Recommendations of Transmission Level HTS Power Cable (송전급 초전도케이블 신뢰성평가를 위한 시험방법)

  • Park, J.;Yang, B.;Kang, J.;Cho, J.;Lee, S.;Shim, K.;Kim, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.29-33
    • /
    • 2010
  • For last 10 years, there are big progress and many efforts in the development of HTS power equipments by some country including South Korea. Especially HTS cable system is the strongest candidate among them from the viewpoint of applying to real grid, because of the feature of it, compact and large capacity. In South Korea, transmission level 154kV, the world top voltage class, HTS cable system was installed and has been tested in KEPCO Gochang Underground Cable Test Field since the early of 2010 in order to meet test requirements made by KEPCO, the only grid company in South Korea. The type test of it will be completed by October 2010 and subsequently long-term load cycle test will be performed during 6 months. Also in the near future, KEPCO has a plan to demonstrate transmission level HTS cable system in real grid, in order to meet practical requirements and confirm the feasibility of it. This paper says the test plan of transmission level 154kV HTS cable system and the way how to test it.

Test Method of Communication Reliability based on HPGP between PEV and EVSE (전기차와 충전기 간 HPGP 기반 통신 신뢰성 테스트 방안)

  • Choi, Byeong-Gon;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Smart Grid is a next-generation intelligent grid to optimize energy efficiency by integrating information and communication technologies to the existing power grid as a two-way exchange of information. HPGP communication standard for smart grid implementation has been developed for the emerging smart energy, home automation, electric vehicle communications applications. HPGP communication standard has the advantage of reducing cost and power consumption. Also, it can be interoperated with the previous HPAV communication standard. For the introduction of a new communication standard, the analysis of the reliability and interoperability verification is required. In this paper, we present sniffer test method as reliability test method about power line communication between PEV(Plug-in Electric Vehicle) and EVSE(Electric Vehicle Supply Equipment). Power line communication between PEV and EVSE is one of the most important Smart Gird applications. Also, we analyzed sniffer test results about power line communication based on HPGP between PEV and EVSE by using QCA7000 device, AVitar and Tool kit.

Comparison of Images Using Optimized Grid and Images Using Grid Supperession Software in the Diagnosis of Micro Lesions (미세병변 진단에서 Optimized Grid을 사용한 영상과 Grid Supperession Software를 사용한 영상의 비교분석)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.149-155
    • /
    • 2018
  • Quantitative analysis was performed to confirm that moire artifact was removed without loss of image when using grid suppression software in the diagnosis of micro lesions. we showed that grid suppression images can be morphologically different from original images as they are significantly lower than those of the optimized grid in the similarity analysis with reference images in mammographic phantom images. We were confirmed that images of microcalcification with smaller signal than noise were lost because the pixel values of all lesions increased significantly after the grid suppression, The change in contrast using the NORMI 13 X-ray test phantom was reduced to 30% of the reference image, This result was significantly lower than the 90% when using the optimized grid. In conclusion, the use of grid suppression software in clinical images should be carefully considered because of the possibility of misdiagnosis due to micro lesion loss and morphological changes.

High-Speed Wind Tunnel Test on Rocket Booster Separation (로켓 부스터 분리 고속 풍동시험)

  • Ra, Seung-Ho;Kim, In-Sun;Ok, Ho-Nam;Oh, Bum-Seok;Lee, Joon-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.10
    • /
    • pp.75-81
    • /
    • 2005
  • Jettison, grid and CTS test are widely used for the store and stage separation studies. This is an introductory paper on the experimental methodology and typical results of grid and CTS test used for the Korean 3-stage sounding rocket development. Thirteen separation trajectories were evaluated in the ONERA S2MA wind tunnel at Mach numbers of 2.0 and 2.8. The test result was applied as the basic database for the design of optimized separation device.