멀티레벨 스위칭 회로를 이용한 트렌스리스형 계통 연계 인버터의 동작 특성 (Operation Characteristic of Transless type Grid-connected Inverter using Multi-level Switching circuit)

  • 김주용;노쾌협;정태욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.916-917
    • /
    • 2008
  • In this paper, Switching damage of switches that is used to proposed power conversion system is reduced by soft switching way. dissipation by part resonance and my resonance stress for resonance of resonance circuit are decreased. Is acted by conversion system high effectiveness. Have following characteristic. Design snubber circuit that is used by switch protection in existent hard work rate Topology by resonant circuit for sogt switching, circuit structure was simple and control system is easy. Also, Can generate free output voltage by multi level Tuesday of output that use individuation Power Cell's Phase Shift PWM, and Low-end switching frequency the harmonic is few.

  • PDF

Propulsive Performance Analysis of Ducted Marine Propulsors with Rotor-Stator Interaction

  • Jang, Jin-Ho;Yu, Hye-Ran;Jung, Young-Rae;Park, Warn-Gyu
    • Journal of Ship and Ocean Technology
    • /
    • 제8권1호
    • /
    • pp.31-41
    • /
    • 2004
  • A ducted marine propulsor has been widely used for the thruster of underwater vehicles for protecting collision damage, increasing propulsive efficiency, and reducing cavitation. Since a single-stage ducted propulsor contains a set of rotor and stator inside an annular duct, the numerical analysis becomes extremely complex and computationally expensive. However, the accurate prediction of viscous flow past a ducted marine propulsor is essential for determining hydrodynamic forces and the propulsive performances. To analyze a ducted propulsor having rotor-stator Interaction, the present work has solved 3D incompressible RANS equations on the sliding multiblocked grid. The flow of a single stage turbine flow was simulated for code validation and time averaged pressure coefficients were compared with experiments. Good agreement was obtained. The hydrodynamic performance coefficients were also computed.

다시기 TM 밴드 6와 DEM을 이용한 지형별 온도변화(서울시 영역을 대상으로) (Temperature Variation by Terrain Using Multitemporal TM Band 6 and DEM(With Seoul City Area))

  • 박민호
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 추계학술발표회 논문집
    • /
    • pp.203-210
    • /
    • 2004
  • The average temperatures by the land cover class, by the elevation extent, by the slope and by the aspect have been calculated using multitemporal Landsat TM band 6 and DEM. For this, the TM band 6 data from October 21, 1985, June 2, 1992, September 1, 1996, May 7, 2000 and the 28.5m x 28.5m grid elevation data of Seoul have been used. From the varying curve of the average land surface temperature by the elevation extent, the presence of the atmospheric inversion phenomenon and the scope of the inversion layer can be inferred. Especially, the average land surface temperature by the aspect can be effective for deciding a road line. For these reasons, it is expected that temperature estimation using remote sensing data shall be effective for the survey of heat damage, environmental temperature monitoring, and urban and environmental Planning usage.

  • PDF

The Field of Power/Ground Planes influenced by the HPEM Source, and its Damage Reduction

  • Kahng, Sung-Tek;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.406-410
    • /
    • 2012
  • This paper looks into the field inside the wide rectangular box structure that is excited by the High Power Electromagnetic(HPEM) source as a potential threat to electric grid and communication networks causing malfunction or destruction. The rectangular box is assumed power/ground planes and its internal field is calculated by the cavity model with the lightning strike excitation as an HPEM pulse. The accuracy of the calculation method employed here is validated through a $156mm{\times}106mm{\times}508{\mu}m$ parallel metallic plate case which is manufactured and tested, and is applied to the size of a building. With the help of the cavity model that takes into account loading, the level of the electric field is shown to decrease when a metal pillar is loaded between the power and ground planes.

PV 시스템의 계통연계를 위한 새로운 고립운전 방지 알고리즘 (A Novel Anti-islanding Algorism for Utility Interconnection of PV System)

  • 윤중혁;김흥근;최종우;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.271-273
    • /
    • 2005
  • Islanding of PV systems occurs when the utility grid is removed but local sources continue to operate and provide power to local loads. Islanding is one of the serious problems in an electric power system connected with dispersed power sources. Also, this can present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

Virtual Qualification을 통한 자동차용 전장부품의 수명 평가 (Life Assessment of Automotive Electronic Part using Virtual Qualification)

  • 이해진;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.143-146
    • /
    • 2005
  • In modern automotive control modules, mechanical failures of surface mounted electronic components such as microprocessors, crystals, capacitors, transformers, inductors, and ball grid array packages, etc., are mai or roadblocks to design cycle time and product reliability. This paper presents a general methodology of failure analysis and fatigue prediction of these electronic components under automotive vibration environments. Mechanical performance of these packages is studied through finite element modeling approach fur given vibration environments in automotive application. Using the results of vibration simulation, fatigue lift is predicted based on cumulative damage analysis and material durability information. Detailed model of solder/lead joints is built to correlate the system level model and obtain solder strains/stresses. The primary focus in this paper is on surface-mount interconnect fatigue failures and the critical component selected for this analysis is 80 pin plastic leaded microprocessor.

  • PDF

OPMT 초음파 트랜스듀서를 이용한 평판구조 이상진단 (Nondestructive Evaluation of plate structures using the Ultrasonic Transducer OPMT)

  • 김윤영;조승현;이주승;선경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.423-427
    • /
    • 2004
  • In this work, we propose a new ultrasonic damage inspection method in plate structures. The proposed method employs an OPMT (Orientation-adjustable Patch-type Magnetostrictive Transducer) in order to make the ultrasonic waves focused on the specific target point. For experiments, virtual grid points were set up at every 50 mm in an aluminum plate and two OPMTs were used for inspection. If there exists a crack in a plate, the reflected Lamb wave from the crack is measured in addition to the direct waves from the transmitting transducer to the receiving transducer.

  • PDF

Experimental Study on Seismic Behavior of Roof Joint

  • Cui, Yao;Gao, Xiaoyu;Liu, Hongtao;Yamada, Satoshi
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1373-1383
    • /
    • 2018
  • Experimental study was conducted to investigate the seismic behavior of roof joint. Eight full-scale specimens were tested considering the effects of axial force, joint height, hole shape of base plate and edge distance of concrete on the failure mode and resistance capacity of roof joint. With the increase of axial force, the hysteretic curves were fuller. The mechanical model of roof joint change from bending to shear. With the increase of joint height, the ultimate strength of roof joint decreased. If the hole shape of base plate changed from circle to loose, the slip behavior of roof joint appeared and the ultimate strength of roof joint decreased. The damage of edge concrete may occur if the edge distance of concrete was not big enough.

지자기 교란으로 인한 전력망 유도전기장 예상값 검증 (Verification on the Calculated Geoelectric Field on Power Grid during Geomagnetic Disturbances)

  • 박성원;유충현
    • 한국전자파학회논문지
    • /
    • 제26권1호
    • /
    • pp.94-100
    • /
    • 2015
  • 태양흑점폭발로 인해 방출되는 코로나 물질은 지자기 교란을 일으킨다. 대규모 지자기 교란으로 인한 유도전류는 변압기 손상을 일으킬 수 있다. 이러한 유도전류를 산출하기 위해 먼저 유도전기장을 산출해야 한다. 푸리에 변환 방법을 적용한 유도전기장 산출방법은 정확도가 높으나, 1일 24시간 동안의 관측 데이터가 필요하다. 반면, 적분 공식을 적용한 유도전기장 산출방법은 실시간 데이터로 산출이 가능하나, 정확도 확인이 요구된다. 이 논문에서 적분 구간을 조정하여 푸리에 변환 방법의 결과값과 오차를 줄이고자 하였다. 그 결과, 적분 공식을 적용한 유도전기장 예상값은 푸리에 변환방법의 예상값과 상관성이 높았으며, 적분 공식으로 산출한 유도전류 예상값은 유도전류 관측값과 시간 동기 및 방향이 일치하고, 그 크기가 오차 범위 1 A 이하에서 92 % 이상 일치함을 확인하였다.

해양플랜트의 화재 및 폭발 예측을 위한 메탄 연소의 CFD 시뮬레이션 (CFD Simulation of Methane Combustion for Estimation of Fire and Explosion in Offshore Plant)

  • 석준;정세민;박종천;백점기
    • 한국해양공학회지
    • /
    • 제27권2호
    • /
    • pp.59-68
    • /
    • 2013
  • Because of the recent increase in maritime cargo capacity, the production and price of crude oil have been rising. As oil prices have risen, many problems have occurred in the industry. To solve these problems, marine resources are being actively developed, and there has been an increase in the orders for special vessels and marine structures for the development of marine resources. However, consequently, various kinds of accidents have also occurred in these special vessels and structures. One of the major types of accidents involves fire and explosion, which cause many casualties and property damage. Therefore, various studies to estimate and prevent such accidents have been carried out. In this study, as basic research for the prevention of fire and explosion, numerical simulations on combustion were carried out by using a commercial grid generation program, Gridgen, and a CFD program, ANSYS-CFX. The influences of some parameters, such as the grid system, turbulence model, turbulent dissipation rate, and so on, on the simulation results were investigated, and optimum ones were chosen. It was found that the present results adopting these parameters agreed moderately well with other experimental and numerical ones.