• Title/Summary/Keyword: Greenhouses

Search Result 639, Processing Time 0.021 seconds

Estimation of Modal Parameters for Plastic Film-Covered Greenhouse Arches (비닐하우스 아치구조의 모달계수 산정)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • To a series of vibration records obtained from experimental modal testing using a fixed hammer and roving accelerometers for greenhouse arch structures, modal parameters such as natural frequencies, damping ratios and mode shapes are extracted by applying the two most advanced system identification methods in the frequency-domain up to now, so-called PolyMAX and FDD. The former involves both input and output data, while the latter utilizes only the output data. The possibility of determining the static buckling load, detecting damages, etc., for very slender steel-pipe arches by means of a non-destructive testing method based on vibration measurements is primarily investigated. The extracted modal parameters generally correlated well with those obtained using finite element analysis, demonstrating promising results for further on-going research.

Modal Testing of Arches for Plastic Film-Covered Greenhouses (비닐하우스 아치구조의 모달실험)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.57-65
    • /
    • 2010
  • To determine the static buckling loads and evaluate the structural performance of slender steel pipe-arches such as for greenhouse structures, a series of modal tests using a fixed hammer and roving sensors was carried out, by providing no load, then a range of vertical loads, on an arch rib in several steps. More attention was given to an internal arch where vertical and horizontal auxiliary members are not placed, unlike an end arch. Modal parameters such as natural frequencies, mode shapes and damping ratios were extracted using more advanced system identification methods such as PolyMAX (Polyreference Least-Squares Complex Frequency Domain), and compared with those predicted by commercial FEA (Finite Element Analysis) software ANSYS for various conditions. A good correlation between them was achieved in an overall sense, however the reduction of natural frequencies due to the existence of preaxial loads was not apparent when the vertical load level was about up to 38% of its resistance. Some difficulties related to the field testing and parameter extraction for a very slender arch, as might arise from the influences of neighboring members, are carefully discussed.

Remote monitoring of light environment using web-camera for protected chrysanthemum production (웹 카메라를 이용한 시설 내 국화생산 광 환경 원격 모니터링)

  • Chung, Sun-Ok;Kim, Yong-Joo;Lee, Kyu-Ho;Sung, Nam-Seok;Lee, Cheol-Hwi;Noh, Hyun-Kwon
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.4
    • /
    • pp.447-453
    • /
    • 2015
  • Increase of national family income improved demand of high-quality and year-round horticultural products including chrysanthemum. To meet these demand, farmers have introduced protected facilities, such as greenhouses, of which environmental conditions could be monitored and controlled. Environment management up to three weeks after transplanting is critical for chrysanthemum quality. Artificial lighting and light-blocking screen are especially important for long-day (day period > 13 hours) and short-day (night period > 13 hours) treatments. In this study, a web-camera was installed, and the image was obtained and transmitted to mobile phones to monitor the status of 3-wavelength(RGB) lighting environments. RGB pixel values were used to determine malfunctioning of the lighting lamps, and leaking out and incoming illumination status during short-day and long-day treatment periods. Normal lighting lamps provided RGB pixel values of 240~255. During long-day treatment period, G pixel values were useful to detect abnormal lighting conditions (e.g., leaking). During short-day treatment period, R pixel values were useful to determine incoming light (e.g., sun-light). Results of this study would provide useful information for remote monitoring of light conditions for protected chrysanthemum production under artificial lights.

Household Characteristics and Housing Deficits of Low-Income Renter Households in Housing Poverty: Focused on the 2014 Korea Housing Survey (주거빈곤 저소득 임차가구의 특성 및 주거문제: 2014년도 주거실태조사를 중심으로)

  • Lee, Hyun-Jeong
    • Human Ecology Research
    • /
    • v.54 no.2
    • /
    • pp.155-164
    • /
    • 2016
  • This study explored the characteristics, housing deficits and expectations for support programs of low-income renter households in housing poverty in order to provide housing policy development and improvement information. Microdata of the 2014 Korea Housing Survey was utilized as secondary data for this study. A total of 2,508,672 low-income renter households (weighted count) in the bottom 40% income ranks of entire general households living in private rental units were selected as study subjects. The major findings were as follows. (1) One point four percent of the subjects were living in non-house living quarters (e.g., shanties, vinyl greenhouses, container houses, and mud huts), 1.4% were in dosshouses, 9.9% were in basements, semi-basements or rooftop units, and 8.2% were in sub-standard units. (2) Among the households whose housing costs burdens were measurable, 75.7% were found to have housing cost burdens to pay 30% or more of their household income towards housing costs (rental costs and maintenance costs), but only 7.5% of the burdened households received a housing voucher. (3) Eighty-one percent were found to be in a housing poverty status as defined by the researcher; in addition, low-income renter households in housing poverty in Seoul tended to have a greater proportion of households headed by females, the elderly, and be persons with low-education or disabilities. (4) Households in housing poverty showed greater expectations for financial support and/or extended provisions of public rental housing than other low-income renter households.

Characteristics of Asphalt Concrete Mixed with Polyethylene Aggregate (폐비닐 골재 혼합 아스콘의 성질)

  • Kim, Youngchin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.12
    • /
    • pp.5-11
    • /
    • 2017
  • The 19 mm-sized aggregate was produced by melting vinyl waste (waste polyethylene film) generated from vinyl greenhouses in rural areas. It was mixed with As'cone at various weight ratios, and then insulation effect test, tension test after repeated freezing and thawing, ice pull-out strength test and field density test were conducted for the mixtures. These results demonstrated that as the mixing ratio of polyethylene aggregate increased, the insulation effect increased, due to the many pore spaces that existed in the polyethylene aggregate. After repeatedly freezing and thawing As'cone, the tensile strength significantly increased at 2.5% of the polyethylene aggregate content rather than 0% of polyethylene aggregate content but it also slightly decreased at 5% and 10% of polyethylene aggregate content in comparison to 2.5% of its polyethylene aggregate content. As'cone added with polyethylene aggregate by 2.5% resulted in lower ice pull-out strength than that of normal As'cone. As a result of the porosity test for the samples taken at the site, porosity of the As'cone, which added polyethylene aggregate, was smaller than that of the general As'cone.

Toxicity of Pesticides to Minute Pirate Bug, Orius strigicollis Poppius (Hemiptera: Anthocoridae), a Predator of Thrips (총채벌레의 천적인 으뜸애꽃노린재에 대한 농약 독성)

  • Ahn Ki-Su;Lee Ki-Yeol;Kang Hyu-Jung;Park Sung-Kyu;Kim Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.43 no.3 s.136
    • /
    • pp.257-262
    • /
    • 2004
  • Toxicities of 51 pesticides (25 insecticides, 11, acaricides, 11 fungicides and 4 adjuvants) commonly used to control greenhouse insect, mite, and disease pests were evaluated to minute pirate bug, Orius strigicollis nymphs and adults at the recommended concentration. Among 25 insecticides tested, fipronil, lufenuron, acetamiprid+fipronil, $\alpha$-cypermethrin+flufenoxuron and buprofezin + amitraz showed low toxicity to O. strigicollis. Among acaricides, acequinocyl, bifenazate, chlorfenapyr, etoxazole, fenpyroximate, flufenoxuron, milbemectin, spirodiclofen and tebufenpyrad showed low toxicity to O. strigicollis. All fungicides and adjuvants tested were very low toxicity. It may be suggested from these results that five insecticides, nine acaricides, eleven fungicides and four adjuvants could be incorporated into the integrated thrips management system with O. strigicollis in greenhouses.

Effects of Soil Moisture Control and Dormancy Breaking Agents on Bud Burst and Fruiting for Double Cropping System in a Year in 'Kyoho' Grapes (포도 '거봉' 2기작재배를 위한 하계휴면타파에서 토양수분 조절과 휴면타파제 처리가 발아에 미치는 영향)

  • 오성도;김용현;최동근
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.61-66
    • /
    • 2002
  • Double cropping system in a year in Kyoho grapes (Vitis labruscana L.) has currently been attempted in the plastic greenhouse. One of the problems in double cropping system is the promotion of bud break in summer season and shoot fertility. Effects of the control of soil moisture tension near the root zone and treatments of bud dormancy breaking agents on bud breaking in summer were examined to promote the bud break for the second fruiting. The lignification of shoots was induced in July or August by the control of soil moisture tension in root zone environment. The first shoot growth was almost the same as that in common plastic greenhouses. The highest bud break value appeared in the plot of cyanamide chemicals mixed with merit blue as over 75% bud break rate. The bud break rate in the discontinuing plot in irrigation showed significantly higher in bud break than that in the continuing plot in irrigation. Despite of the final high bud break rate, the time of bud break was irregular.

Optical Characteristics of Two New Functional Films and Their Effect on Leaf Vegetables Growth and Yield (2종류의 기능성필름이 광학특성과 엽채류 생육과 수량에 미치는 영향)

  • Kwon, Joon Kook;Khoshimkhujaev, Bekhzod;Park, Kyoung Sub;Choi, Hyo Gil;Lee, Jae-Han;Yu, In Ho
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.314-320
    • /
    • 2014
  • Three leaf vegetables, namely green lettuce, red lettuce (Lactuca sativa) and red-veined chicory (Cichorium intybus) were grown in minigreenhouses covered with two new functional films and conventional polyethylene film (PE). Seedlings of leaf vegetables were transplanted in a plastic troughs filled with soil-perlite mixture. Two functional films were made from polyolefin (PO) material. Measurement of optical characteristics showed that polyolefin films have better transmittance for the photosynthetic active radiation (PAR, 400-700nm) and higher absorptance for the ultraviolet radiation (UV, 300-400nm) in comparison with the conventional PE film. After three months of utilization higher loss in PAR transmittance was observed for conventional PE film. Leaf vegetables growth was enhanced and yield was increased in greenhouses covered by new functional films.

Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation (CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석)

  • Ha, Jung-Soo;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System (수막하우스의 유량 및 수온에 따른 열전달 특성 분석)

  • Kim, Hyung-Kweon;Kim, Seoung-Hee;Kwon, Jin-Kyeong
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.