• Title/Summary/Keyword: Greenhouses

Search Result 639, Processing Time 0.033 seconds

New Records of Fungi Isolated from Indoor Air of Greenhouse Used for Shiitake Cultivation in Korea (표고 재배사 실내 공기에서 분리한 국내 미기록 진균)

  • Kwon, Hyuk Woo;Yun, Yeo Hong;Kim, Jun Young;Kim, Seong Hwan;Ko, Han Kyu
    • The Korean Journal of Mycology
    • /
    • v.43 no.1
    • /
    • pp.58-63
    • /
    • 2015
  • Mold contamination is one of the detrimental factors affecting sawdust media-based shiitake cultivation in greenhouses. During mold monitoring of indoor air of greenhouses, several fungi were isolated. Among them, Aspergillus pulverulentus and Cosmospora butyri were found to be new in Korea and Lecanicillium psalliotae and L. antillanum were known in Korea without taxonomic validation. In this study the morphological characteristics and phylogenetic analysis based on the internal transcribed spacer (ITS) rDNA region or ${\beta}$-tubulin gene of the four identified species were described.

Performance evaluation of a 400 W precise window motor for glass houses

  • Hong, Soon-Joong;Park, Soo-Bok;Kang, Na-Rae;Kim, Yong-Joo;Chung, Sun-Ok
    • Korean Journal of Agricultural Science
    • /
    • v.44 no.4
    • /
    • pp.595-603
    • /
    • 2017
  • Crop growth and production cost are greatly influenced by management of environmental factors such as ambient temperature, humidity, and $CO_2$, especially in protected horticulture. Opening and closing of greenhouses is the most important operation for control of these ambient environmental factors, and precise and stable operation requires high performance window motors. In this study, a 400 W precise window motor was constructed, and its performance was evaluated for plastic and glass greenhouses. First, the motor was designed and fabricated by benchmarking of an advanced foreign product. Then, the performance was evaluated through vibration, PCB (Process Control Block), and load tests. Vibration tests resulted in averaged vibration displacement and velocity of the developed motor of 0.002 mm and 0.2267m/s, which were statistically significantly different from those of the target motor. Average vibration acceleration ($0.26m/s^2$) of the developed motor was also significantly different from that ($0.51m/s^2$) of the target motor. PCB tests showed 2 - 4 mm deviation from the target values, and confirmed the operating status and precision of the control. Load tests with a 300 kg load also showed acceptable operating status and durability. Current values were $1.31{\pm}0.06A$ and RPMs were in the range of 2.9 - 3.0. Considering the above results, the developed window motor would be competitive to the target foreign product.

Development of a Cooling and Heating System for Greenhouse using Geothermal Energy (지열을 이용한 온실용 냉난방시스템 개발)

  • Lee Yong-Beom;Cho Seong-In;Lee Jae-Han;Kim Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.688-692
    • /
    • 2005
  • Importance of substitute energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in Korean protected cultivation needs to be reduced for profitability and global competition. But, studying on substitute energy to solve these problems has not been activated for Korean protected cultivation. Therefore, this study was conducted to develop a geothermal heat pump system for cool ing and heat ing of greenhouses at a lower cost than conventional hot air heater and air conditioner. Fundamental test of heat transfer characteristics in soil was conducted by computer simulation and controlled tests for its verification. Based on the results of the theoretical and empirical investigations, an optimum heat pump system was developed and the performance was evaluated for practical use in a greenhouse at the Pusan Horticultural Experiment Station. The system was compared with a conventional hot air heating system through a cucumber growing test and economic feasibility analysis. Results of the application test of the geothermal heat pump showed that with an initial setting of $15^{\circ}C$ the inside temperature of the greenhouse could be maintained between 15 and $17^{\circ}C$. Results of the cucumber growing test showed that there were no significant differences in average height, leaf length, leaf width, number of nods, leaf area, dry weight and yield between the plots wi th the geothermal heat pump system and a conventional hot air heater. Economic feasibility analysis indicated that the variable cost of the hot air heater could be saved $81.2\%$ using the geothermal heat pump system. It was concluded that the geothermal heat pump system might be a pertinent heating and cooling system for greenhouses because of the low operating cost and the use of environment-friendly geothermal energy.

  • PDF

Comparative Analysis of Accumulated Temperature for Seasonal Heating Load Calculation in Greenhouses (온실의 기간난방부하 산정을 위한 난방적산온도 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.192-198
    • /
    • 2014
  • To establish the design criteria for seasonal heating load calculation in greenhouses, standard weather data are required. However, they are being provided only at seven regions in Korea. So, instead of using standard weather data, in order to find the method to build design weather data for seasonal heating load calculation, heating degree-hour and heating degree-day were analyzed and compared by methods of fundamental equation, Mihara's equation and modified Mihara's equation using normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average heating degree-hours calculated by fundamental equation using thirty years hourly weather data showed a good agreement with them using standard weather data. The 24 times of heating degree-day showed relatively big differences with heating degree-hour at the low setting temperature. Therefore, the heating degree-hour was considered more appropriate method to estimate the seasonal heating load. And to conclude, in regions which are not available standard weather data, we suggest that design weather data should be analyzed using thirty years hourly weather data. Average of heating degree-hours derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data for energy estimation.

Calculated external pressure coefficients on livestock buildings and comparison with Eurocode 1

  • Kateris, D.L.;Fragos, V.P.;Kotsopoulos, T.A.;Martzopoulou, A.G.;Moshou, D.
    • Wind and Structures
    • /
    • v.15 no.6
    • /
    • pp.481-494
    • /
    • 2012
  • The greenhouse type metal structures are increasingly used in modern construction of livestock farms because they are less laborious to construct and they provide a more favorable microclimate for the growth of animals compared to conventional livestock structures. A key stress factor for metal structures is the wind. The external pressure coefficient ($c_{pe}$) is used for the calculation of the wind effect on the structures. A high pressure coefficient value leads to an increase of the construction weight and subsequently to an increase in the construction cost. The EC1 in conjunction with EN 13031-1:2001, which is specialized for greenhouses, gives values for this coefficient. This value must satisfy two requirements: the safety of the structure and a reduced construction cost. In this paper, the Navier - Stokes and continuity equations are solved numerically with the finite element method (Galerkin Method) in order to simulate the two dimensional, incompressible, viscous air flow over the vaulted roofs of single span and twin-span with eaves livestock greenhouses' structures, with a height of 4.5 meters and with length of span of 9.6 and 14 m. The simulation was carried out in a wind tunnel. The numerical results of pressure coefficients, as well as, the distribution of them are presented and compared with data from Eurocodes for wind actions (EC1, EN 13031-1:2001). The results of the numerical experiment were close to the values given by the Eurocodes mainly on the leeward area of the roof while on the windward area a further segmentation is suggested.

Design of energy-efficient routing method for USN based Large scale Glass greenhouses (USN based Large Scale Glass greenhouses를 위한 에너지 효율적인 라우팅 방법)

  • Kang, Hyun-Joong;Kang, Min-Ah;Lee, Myung-Hun;Yoe, Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.685-689
    • /
    • 2007
  • Recently, wireless communication technology and state of art miniaturization has enabled the wireless sensor network with Smart Environmental sensors. The sensor network is a new field which has been researched vigorously in the ubiquitous computing and Ad-hoc network. How to efficiently use the limited energy in this USN(Ubiquitous sensor Networks) has been debated recently. We utilized the Directed Diffusion and Gossiping concept which is based on the Large scale Glass greenhouse and present a method to prolong the lifespan of the sensor network by operating variable time based this routing information on the average energy leftover. In this paper, we present a method to minimize the energy consumption of sensor node within Glass greenhouses and ensure a stable network operation at the same time through energy efficient routing among sensor nodes.

  • PDF

Optimum Design of Greenhouse Roof Shape Using Genetic Algorithms - In Reference to Light Transmissivity - (유전알고리즘을 이용한 온실지붕 형상의 최적설계 - 광투과율을 중심으로 -)

  • 김문기;박우식
    • Journal of Bio-Environment Control
    • /
    • v.7 no.4
    • /
    • pp.290-297
    • /
    • 1998
  • In this study an optimization of greenhouse roof shape was performed to maximize solar light transmission which is one of the most important elements in greenhouse environment. To determine roof shape that maximize the total light transmissivity, a computer model for analysing light transmissivity was composed and the Genetic Algorithms was applied for solving optimization problems. By setting composite model as objective function(fitness function), the optimum combination of design variables(roof inclination angle, width ratio) was searched using Genetic Algorithms. The optimum combination of input variables for the maximum light transmissivity at Suwon in winter was found 40 degree root angle , 0.5 width ratio, for two span greenhouses and 37 $_。 / roof angle, 0.7 width ratio, for single span greenhouses.es.

  • PDF

Reduction of Tomato spotted wilt virus on Table Tomatoes in Greenhouses by Soil Fumigation

  • Kim, Jin-Young;Cho, Jeom-Deog;Kim, Jeong-Soo;Hong, Soon-Sung;Lee, Jin-Gu;Choi, Gug-Seoun;Lim, Jae-Wook
    • The Plant Pathology Journal
    • /
    • v.25 no.2
    • /
    • pp.151-156
    • /
    • 2009
  • Tomato spotted wilt virus (TSWV) has occurred on fields annually disease occurrence rates were 73.3% in 2005, 53.3% in 2006 and 41.6% in 2007 at Anyang area in Gyeonggi Province. Seasonal occurrence pattern of TSWV showed a dramatic increase from 8.7% in late May to 30.1 % in early June in 2007 at Anyang area, coincided with the high population of a thrip, Frank-liniella occidentalis at that time. The rate of viruliferous thrips with TSWV on lettuce and red pepper was 20.2% and 52.1%, respectively, in greenhouses. Dazomat, soil fumigation pesticide, reduced TSWV disease incidence drastically on table tomato as treatment the chemical into the soil with humidity in early spring in 2006 and 2007. Spraying insecticide periodically after treatment with Dazomat was more effective to control TSWV than spraying if on plants or applying into the soil of the insecticide during growing season. Control efficiency through treatments both of the soil fumigation and of spraying insecticide was significantly high with 85.3% in 2006 and 87.8% in 2007. Removing the potential vector from the soil of TSWV infested area can be an effective strategy for reducing TSWV disease.

Eco-friendly Control of Whiteflies by Two-Fluid Fogging System (이류체 포그시스템을 이용한 친환경적 가루이 방제)

  • Kim, Sung-Eun;Lee, Sang-Don;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.120-126
    • /
    • 2012
  • Two experiments were designed and executed to measure the effectiveness of the two-fluid fogging system in controlling whiteflies in tomato cultivation. The two-fluid fogging system that lowers temperature and raises humidity in greenhouses provides an eco-friendly method of preventing damages from whiteflies. The first experiment elucidated the effect of fogging treatment on the elimination of whiteflies and investigated the sectional distribution of whiteflies. The second experiment analyzed the vertical distribution, the motility of whiteflies and reduction of the number of whiteflies under the fogging system. The result of the experiments showed that the fogging system lowered the number of whiteflies and decreased their motility significantly. It affected the vertical distribution of whiteflies as well. Based on these experiments, we strongly recommend using the fogging system to prevent and control whiteflies in greenhouses, in addition to installing yellow sticky traps in the areas that have the highest density of whiteflies.

Performance Evaluation of Closed Co-axial Ground Heat Exchanger in the case of 2000m-Depth Single Well (2000m 단일 시추공에서 밀폐 동축 방식 지중 열교환기의 취득온도 성능평가)

  • Ryoo, Yeon-Su;Kim, Jae-Hyeok;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.83-92
    • /
    • 2016
  • The Korean government has been making efforts to use renewable energy to reduce the consumption of fossil fuels for the heating system in greenhouses. The number of greenhouses that installed a geothermal heat pump system is 201 EA with the volume of 132.8 ha and 108,467kW from 2010-2014. The geothermal system, called a shallow geothermal system, with the temperature of $10-20^{\circ}C$ has accessories composed of a BHE and heat pump. Moreover, it is necessary to have a wide area to install the BHE and to drill to the depth of 200 m. On the other hand, even though the deep geothermal system needs a high drilling cost to obtain the temperature of $40-150^{\circ}C$, the system has the advantages of the small area required for the BHE and operation without a heat pump. In this study, the temperature of the return water and heat capacity were measured to obtain the geothermal energy efficiently on the condition of the water flow being changed in the BHE. The temperature according to the return water changes through the heat conduction based on the increase of ground temperature up to the underground depth has been calculated to conduct a simulation and is compared with the field experiment test results.