• Title/Summary/Keyword: Green roof

Search Result 272, Processing Time 0.025 seconds

The Analysis of Sedum Suitable for the Effect of Modulability the Temperature of the Rooftop Greening (옥상녹화의 온도조절효과에 적합한 세덤류 분석)

  • Lee, Bitnara;Kim, Ye-Seul;Lee, Eun-Heui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.2
    • /
    • pp.53-64
    • /
    • 2015
  • Rooftop greening is the alternative of urban heat island. The purpose of this study is selecting Sedum to the effect of temperature reduction of the rooftop greening. Since the state of growth is excellent, Sedum kamtschaticum, Sedum takesimense and Sedum middendorffianum surveyed as coverage. It was investigated that there is the effect of reducing the temperature. The effect of temperature reduction of Sedum counted compound was found to be associated with state of growth. When you construct a rooftop greening, planting Sedum kamtschaticum, Sedum takesimense and Sedum middendorffianum is helpful to the effect of temperature reduction. Also, the ingredients various types of Sedum in order to reduce the effective temperature, it must be densified. It must demonstrate an additional effect of temperature reduction of Sedum through complementary and continuous monitoring of the future temperature monitoring method.

Evaluation of Thermal Environment of External Space following the Fence Demolition Campaign in Detached Housing Area (담장허물기로 인한 주택지 외부공간의 열환경 평가)

  • Ryu, Ji-Won;Jung, Eung-Ho;Shimizu, Aki;Oh, Sang-Hak;Hoyano, Akira
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • This study examines how fence demolition may change the thermal environments of external spaces of houses and suggests what factors need to be considered when a fence is demolished. The results of the research are summarized as follows. In terms of the surface temperature, there was no significant difference in all time plots after the removal of all materials. However, applying greening methods (changing the surface materials, planting trees, and building a green roof following fence demolition) could lower the surface temperatures, calling for proper plans for various greening methods. The MRT results indicates that walls block solar radiation and provide shade, reducing radiant heat from roads and surrounding structures during the daytime when solar radiation directly effects surface temperatures. Also, the application of greening methods such as planting vegetation and trees could have shading and evapotranspiration effects, leading to a lower temperature distribution. The HIP results were similar to the MRT results. They indicated that walls block solar radiation within the residential sections and provide shade, resulting in a lower temperature distribution during the daytime. However, areas where greening methods such as a green roof or tree planting were applied showed $1{\sim}2^{\circ}C$ difference in temperature distribution.

Resistance to Root Penetration of Root Barrier for Green Roof System (옥상녹화용 방근층 구성재료의 방근성능에 관한 실험적 연구)

  • Kim, Hyun-Soo;Jang, Dae-Hee;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.123-129
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plant: and soils suitable for weather and natural features of Korea. For testing Plants, Plioblastus pygmaed Mitford A and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of roe barrier materials have penetrated roots. Even though two types of them have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe. USA or Japan.

Examination Conditions of Root Barrier for Green Roof System and Result of Intermediate Observation of Three Months against Representative Root Barrier (옥상녹화용 방근층의 방근성 시험조건 설정 및 주요 방근소재에 대한 3개월간의 중간관찰 결과)

  • Shin, Yun-Ho;Jang, Dae-Hee;Kim, Hyun-Soo;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.245-249
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plants and soils suitable for weather and natural features of Korea. For testing plants, Plioblastus pygmaed Mitford A. and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio(volume). Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of root barrier materials have penetrated roots. Even though two types of them(EDPM Sheet, Polyethylene Sheet) have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe or Japan.

  • PDF

Micromolding Technique for Controllable Anisotropic Polymeric Particles with Convex Roof (볼록한 지붕을 갖는 이방성 고분자 입자의 곡률반경 제어를 위한 마이크로몰딩 기술)

  • Jeong, Jae-Min;Son, Jung-Woo;Choi, Chang-Hyung;Lee, Chang-Soo
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.295-300
    • /
    • 2012
  • Synthesis of well-defined particle with tunable size, shape, and functionalities is strongly emphasized for various applications such as chemistry, biology, material science, chemical engineering, medicine, and biotechnology. This study presents micromolding method for the fabrication of anisotropic particles with elegant control of curvature of covex roof. For the demostration of rapid fabrication of the particles, we have applied polydimethylsiloxane (PDMS) micromold as structure guiding template and wetting fluid to control curvature of roof of the particles. Based on this approach, we can control the radius of curvature from $20{\mu}m$ to $70{\mu}m$ with different aspect ratio of mold. In addition, wetting fluids with different wetting properties can also modulate the height and radius of curvature of the particles. We envision that this methodology is promising tool for precise control of particle shape in 3-dimensional space and new synthetic route for anisotropic particles with cost effective, simple, easy, and fast procedure.

A study on vegetation and soil environmental characteristics of green roof in Daejeon Metropolitan City (대전광역시 옥상녹화 지역의 식생현황 및 토양환경 특성에 관한 연구)

  • Lee, Sang-Jin;Park, Gwan-Soo;Lee, Dong-Kun;Jang, Seong-Wan;Park, Beom-Hwan;Lee, Hang-Goo;Yun, Joon-Young;Jang, Kwan-Woo;Lee, Seung-Woo;Lee, Ho-Young;Kwon, Oh-Jung;Lee, Sook-Mee;Kil, Sung-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.4
    • /
    • pp.641-649
    • /
    • 2011
  • This study was to analyze the soil environmental characteristics and vegetation status of green roof in Daejeon Metropolitan City. The investigated floras of vascular plants are 17 families, 26 genera, 28 species in Seo-Gu Daejeon District Office Building (SG), 25 families, 49 genera, 56 species in Galma Public Library (GP), and 34 families, 57 genera, 60 species in Daejeon City Hall (DC) respectively. Although the larger area shows the more numbers of species in introduced plants and naturalized plant, the naturalized plant ratios were similar with each other. They were 10.71%, 10.71%, and 11.67% at SG, GP, and DC respectively. As a result of analysis on soil physical property, soil depths including vegetation soil and drainage soil of 3 green roofs were 30cm. The depths of vegetation soil at SG, GP, and DC were 0~8cm, 0~10cm, 0~10cm respectively. As a results of soil chemical properties of our study, soil pH of vegetation soil and drainage soil were a range of 6.42 and 7.43, and a range of 6.55 and 7.43 on the average respectively. Available-P contents of vegetation soil and drainage soil were a range of 153.33 and 366.33mg/kg, and a range of 136.67 and 242.67 mg/kg which is very high, respectively. Carbon contents in soil at vegetation soil and drainage soil were a range of 3.16 and 6.38%, and a range of 1.63 and 2.47% respectively. Carbon storage per square meter within 30 cm were 2.76 kg, 2.99 kg, and 3.66 kg at SG, GP, and DC respectively.

Characteristice Study of Ancient Northeast Asian Lead Glass and Green Glaze Based on Analysis Results (분석자료를 기초한 고대 납유리와 녹유의 특성 연구)

  • Lee, Jihee;Kim, Hyunjeong
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.99-116
    • /
    • 2020
  • This study examines the results of analyses of the lead isotope ratio and chemical composition of lead glass and green glaze from ancient Northeast Asia in order to suggest their production sites and reveal further characteristics. The comparison of the lead isotope ratio of lead glass and green glaze from two Baekje remains in Iksan-the Wanggung-ri Site and Mireuksa Temple Site-suggests that they were produced to the west of the South Gyeonggi Massif (Zone 4) using lead extracted from the same area. With a few exceptions, it has proved difficult to identify the production sites of most of the green-glazed roof tiles from Unified Silla-period Buddhist temples across Northeast Asia. The major component of the lead glass from Baekje, Silla, China, and Japan during the seventh century is PbO, SiO2, Al2O3, CuO, and Fe2O3, with a ratio of PbO and SiO2 of 70 and 30 wt.%, respectively. The green-glazed roof tiles excavated from a temple from the Unified Silla period have a high proportion of lead, ranging from 64 to 90 wt.%. Green-glazed lozenge tiles excavated from the Sacheonwangsa Temple site in Gyeongju were shown to contain PbO, SiO2, Al2O3, and CuO, a similar composition with lead glass. An experiment was conducted to reproduce a glaze according to the production method mentioned in the Zō hotokesho sakumotsu-chō (Buddhist statue workshop crop book) in the Shosoin Repository. In this experiment, an identical ratio of PbO was observed for Japanese green-glazed ceramics from the eighth to eleventh century as that found in Chinese lead-glazed ceramics excavated from kilns operated from the seventh to tenth century in Henan. This indicates that production methods for lead glass and glaze were shared across Northeast Asia.

Analysis of the Types of External Wall and Roof Structure Layer Composition of CLT Building (CLT 건축물의 외벽 및 지붕 구조체 레이어 구성 유형 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.4
    • /
    • pp.71-78
    • /
    • 2020
  • Today, the whole world is going through a big chaos due to the COVID-19, but paradoxically, the emergence of COVID-19 has been leading to the need for sustainable development, such as Green New Deal that can improve global warming and carbon emissions, and the need for sustainable architecture is growing bigger and bigger in the architectural field as well. The level of CLT buildings in Korea is at a very rudimentary stage, while CLT buildings remedying existing wooden buildings are getting the spotlight among European countries for sustainable architecture. This study was conducted to categorize structure layer compositions of overseas CLT buildings and analyze architectural techniques and materials applied by collecting and analyzing information about CLT structure layer compositions of overseas CLT building-related institutions, companies and cases. When classifying structure layer compositions of foreign CLT buildings depending on the roles of layers. it was revealed that exterior wall structure layers were combined and organized within a sequence of external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, sloped roof structure layers were external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, flat roof structure layers were external finishing, ventilation, waterproof, planking wood, external insulation, waterproof, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing.

Evaluating Changing Trends of Surface Temperature in Winter according to Rooftop Color using Remotely Sensed Thermal Infrared Image (원격 열화상을 이용한 지붕색상별 겨울철 표면온도 변화추세 비교 평가)

  • Ryu, Taek Hyoung;Um, Jung Sup
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.1
    • /
    • pp.27-37
    • /
    • 2013
  • A roof surface temperature monitoring, utilizing remotely sensed thermal infrared image has been specifically proposed to explore evidential data for heating load in winter by cool roof. The remotely sensed thermal infrared image made it possible to identify area-wide patterns of changing trends of surface temperature according to rooftop color (white, black, blue, green) which cannot be acquired by traditional field sampling. The temperature difference of cool roof having a higher solar reflectance were ranged from $3^{\circ}C$ up to $9^{\circ}C$, compared to the general roofs. It is confirmed that there is a significant potential to the energy saving by introducing the cool roof in a Korean climate since up to $18.46^{\circ}C$ difference in cool roof, compared to the general roofs in summer were already identified in Seoul, South Korea. It is anticipated that this research output could be used as a valuable reference in identifying heating load in winter by cool roof since an objective monitoring has been proposed based on the area-wide measured, fully quantitative performance of remotely sensed thermal infrared image.

A Case Study on the Actual Conditions of Ecological Environment of the High School Facilities in Gyeongnam Area (경남지역 고등학교시설의 생태환경 실태에 관한 사례 연구)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • This study is to clarify the actual conditions of high school of environment friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of the study, First, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment friendly architecture and certification high school, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Second, actual condition of ecological environment elements per non-certification high school by collecting actual data of certification schools environment friendly architecture were analyzed and the results are as the follows. The average of ecological area ratio was 17.8 percent in case of non-certification school facilities it was analyzed that the natural based green area ratio was 17.5 percent, continuous green axis length ratio was 19.0 percent and roof green garden area ratio was 0 percent.