• Title/Summary/Keyword: Green Area Ratio

Search Result 306, Processing Time 0.024 seconds

A Study on the Actual condition and Composition Method of Environment-Friendly Architecture of the Elementary School Facilities -Focused on Ecological Environment- (초등학교시설의 친환경건축 조성기법과 실태 연구 -생태환경을 중심으로-)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.4
    • /
    • pp.69-76
    • /
    • 2010
  • The purpose of this study is to clarify the actual condition of real certification schools of environment-friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of this study, firstly, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment-friendly architecture and eco-school pilot model project, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Secondly, actual condition of ecological environment elements per school grade by collecting actual data of certification schools environment-friendly architecture were analyzed. The average of ecological area ratio was 23.3 percent in case of this certification regardless of school grade and region and it was analyzed that the natural based green area ratio was 20.6 percent, bio-tope area ratio was 0.73 percent and ecological learning places area ratio was 0.43 percent.

A Comparative Analysis of the Energy Load due to Window Area Ratio of Domestic Public Buildings

  • An, Kwang-Ho;Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • In the case of public buildings, fast communication and transparency in the administration and the public, as well as ensuring visibility and lighting performance using a glass curtain wall is symbolically expressed through the transparent glass skin. This study is a simulation in order to derive the basic data for the establishment of the improvement of the heating and cooling load analysis according to the window area ratio changes with respect to the high effectiveness of the government's large public building energy consumption analysis and green building certification system of guidelines was analyzed by a change in the energy load. Glass curtain wall is light and visibility, the symbolic meaning of communication, etc., but is widely used in a variety of characteristics, in terms of energy consumption being disadvantaged sheath plan should have been. Design, including the Atrium, is much less energy than energy consumption by the window area ratio. Thus, while compliance with design guide lines, the atrium and I like the burden of a large space ratio and energy load consists of only glass suggest that require more research on that given in the guidelines.

Runoff Reduction Effect of Rainwater Retentive Green roof (저류형 옥상녹화의 우수유출저감에 대한 연구)

  • Baek, So-Young;Kim, Hyun-Woo;Kim, Mi-Kyeong;Han, Moo-Young
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.67-71
    • /
    • 2016
  • Purpose: There is a growing interest in rainwater runoff reduction effect of green roof, as flooding caused by increasing impervious surface is becoming more and more frequent in urban areas. This study was conducted to prove runoff reduction and runoff delay effect of the retentive green roof and to investigate its influencing factors to the rainfall events that occurred in the summer of 2013. Method: The experiment intended to monitor the runoff quantity of the retentive green roof($140m^2$) and normal roof($100m^2$) in #35 building in Seoul National University, Seoul, Korea for 75 days in 2013. Result: On analysis of 9 rainfall events, it showed that the retentive green roof has 24.8~100% of runoff reduction ratio, 21.2~100% of peak flow reduction ratio, 0.5~3.75 hours of peak delay, and $1.8{\sim}7.2m^3$ of retaining capacity in an area of $140m^2$. It shows different results depending on rainfall and antecedent dry days. The results show that runoff reduction effect is effective when the rainfall is less than 50 mm and antecedent dry day is longer than five days on average. By installing retentive green roofs on buildings, it can help mitigate urban floods and rehabilitate urban water cycle.

Investment Analysis of the Modernized Green Houses in Korea (현대화 온실의 투자분석)

  • Lee, Kwang-Won;Lim, Jae-Hwan;Lee, Doo-Hee
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.170-181
    • /
    • 1997
  • The number of modernized green houses have been increased to produce high quality and high-payoff farm products. The unit investment costs per pyeong($3.3058m^2$) for building a glass house was estimated at 449 thousand won. On the other hand, the unit prices for the PC house with iron frame and the vynil house with automatic control system were revealed 365 thousand won and 93 thousand won respectively. The main objective of the study was to identify the financial feasibility of the green house investment prevailed in rural area. At present, some farmers have selected the green house without any consideration of profitability of crops and accessiblity of their fanning practices and technology. For the soundness of green house cultivation and management, the indices of finacial efficiency for the modernized green houses were necessary. The decesion making criteria such as NPV(Net Present Value), IRR(Internal Rate of Return), B/C Ratio and Payback Period were analyzed for the individual high investment facilities considering the present farmer's technology and on-farm benefits and costs. The results of the feasibility analysis of green houses were as follows: 1. In case of 100% private burden of the investment costs, NPV revealed only positive value for the vinyl house with automatic system and IRR for the house was also estimated at more than 10% and B/C Ratio was amounted to more than 1.0. On the other hand, the other glass and PC houses showed negative NPV and unacceptable B/C ratio and IRR. 2. In case of the following terms and conditions as 50% Government subsidy, 20% loans and 30% farmers burden of the total investment cost, all the green houses showed acceptable IRR, B/C Ratio and NPV. 3. The financial feasibility of the glass house was acceptable in tomato cultivation rather than in cucumber cultivation. The payback periods of cucumber were represented as 8.9 years for glass house, 8.5 years for PC house and 4.1 years for vinyl house with automatic system respectively. In conclution, the glass and PC house cultivation of high value vegetables were only acceptable under the Goverment subsidy and loan systems from the view point of farmer's financial situations. On account of the unacceptable economic rate of return, the government subsidy and loan policy for glass house cultivation should be transfered to the vinyl and pc houses in the future.

  • PDF

Effect of the Urban Land Cover Types on the Surface Temperature: Case Study of Ilsan New City (도시지역의 토지피복유형이 지표면온도에 미치는 영향: 경기도 일산 신도시를 중심으로)

  • Kim, Hyun-Ok;Yeom, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.203-214
    • /
    • 2012
  • The physical environment of urban areas covered mostly by concrete and asphalt is the main cause of the urban heat island effect, primarily becoming apparent through increased land surface temperature. This study examined the effect of different urban land cover types on the land surface temperature using MODIS, Landsat ETM+ and RapidEye satellite data. As a result, the remote sensing based land surface temperature showed a marked difference according to the land use pattern in the case study of Ilsan new city. The high-rise apartment residential districts with less building-to-land ratio and higher green area ratio revealed lower land surface temperature than the low-story single-family housing districts characterized by relatively high building-to-land ratio and low green area ratio. From the view of climate zone and land cover types, there is a strong linear correlation between the impervious land cover ratio and the land surface temperature; the land surface temperature increases as the impervious built-up areas expand. In contrast, vegetation;water and shadow areas affect the decrease of land surface temperature. There is also a negative (-) correlation between NDVI and land surface temperature but the seasonal variation of NDVI can be hardly corrected.

Development and Application of the Assessment Method of No Net Loss of Greenness for Urban Ecosystem Health Improvement (도시생태계 건전성 증진을 위한 녹지총량 평가법 개발과 적용)

  • Kim, Seung-Hyun;Kong, Hak-Yang;Kim, Tae-Kyu
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.311-316
    • /
    • 2015
  • This study defined and classified no-net-loss-of-greenness (NNLG) based on the law, and then assessed the NNLG index by metropolitan cities and provinces in Korea after estimating NNLG evaluation indicators for the introduction of NNLG for health improvement of urban ecosystems. The results are as follows. First, NNLG was the comprehensive meaning that was included in the greenbelt and park greenbelt and the green area which was defined by the Act on Urban Parks, Greenbelts, etc. and the National Land Planning and Utilization Act respectively. Second, NNLG was classified as a park greenbelt which was included urban parks and greenbelts such as buffer greenbelts, scenic greenbelts, and connecting greenbelts, green areas which was included in green conservation areas, green production areas, green natural areas, and green coverage which is included forests, grasslands, and wetlands that were occupied by vegetation such as trees, shrubs, and plants. Third, NNLG index by cities and provinces was assessed based on the estimation of NNLG evaluation indicators, which included parks and greenbelt areas per capita, green areas per capita, green coverage per capita, ratio of parks and greenbelts, ratio of green areas, and ratio of green coverage. As a result, Sejong city got the highest point of NNLG index and Seoul and Daegu got lowest points of NNLG index among metropolitan cities in Korea. Chungbuk got the highest point of NNLG index and Kyonggi and Jeju got lowest points of NNLG index among provinces in Korea.

Heat Mitigation Effects of Urban Space based on the Characteristics of Parks and their Surrounding Environment (도시공원 및 주변환경의 특성이 도시공간의 온도저감에 미치는 영향)

  • Suh, Jung-Eun;Oh, Kyu-Shik
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.1-14
    • /
    • 2020
  • In order to improve the urban thermal environment, efforts are being made to increase green areas in cities that include park construction, planting, and green roofing. Among these efforts, urban parks play an important role not only in improving the urban thermal environment, but also in terms of ecosystem services (serving as resting places for citizens, providing cleaner air quality, reducing noise, etc.). Therefore, the purpose of this study is to suggest planning and management guidelines for urban parks that are effective in improving the thermal environment, by analyzing the urban surface temperature reduction performance of urban parks. To do this, first, land surface temperature was calculated by using Landsat 8 images. Second, the PCI (Park Cool Island) index was calculated to identify the temperature reduction performance of urban parks. Third, the characteristics of parks (area, shape, vegetation) and the surrounding spatial characteristics (land cover, building-related variables, etc.) were identified. Finally, the relationship between the PCI indices (PCI scale, PCI effect, PCI intensity) and the characteristics of the parks and their surroundings were analyzed. The results revealed that the parks consisting of a larger area, simple shape, and higher tree coverage ratio had increased PCI performance, and were advantageous for improving the urban thermal environment. Meanwhile, PCI performance was found to have decreased in areas with a higher impermeable area ratio and building coverage ratio. The outcomes of this study can be used to identify priority areas for planning and management of urban parks and can also be utilized as planning and management guidelines for improving urban thermal environment.

Planting Structure and Ecological Characteristics of Green Spaces at the Dangjin Steam Power Plant (당진화력발전소 녹지공간의 식재현황 및 생태적 특성 분석)

  • Kang Hyun-Kyung;Lee Soo-Dong;Han Bong-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.78-89
    • /
    • 2006
  • This study was conducted to analyze the planting structure and ecological characteristics of greon spaces on the grounds of e Dangjin steam power plant. To achieve these goals, we surveyed existing vegetation, plant community structure, Plant volume and growth rate. Based on e vegetation analysis, existing vegetation was classified into six types: herbaceous species $(70.54\%)$, evergreen coniferous trees $(21.17\%)$, deciduous broad-leaved trees $(5.10\%)$, deciduous coniferous trees $(1.47\%)$, shrubs $(0.12\%)$, and other types $(1.59\%)$. The coal storage, office, and playground areas were community is the natural forest area where a Pinus thunbergii / Pinus densiflora community is distributed in terms of vegetation structure, species diversity, plant volume, and growth rate. The artificial green spaces(near the coal storage, office, playground areas) had a single-layer structure. Species diversity indices of the artificial green areas were $0.1655\~0.4807$ compared to 0.8628 in the natural forest, which presented a good growth environment. Also, the plant volume in the artificial green space was lower than that of the natural green space. Therefore, it would be desirable to develope a multi-layer structure similar to that of the vegetation in the natural green space in order to improve the amount of plant volume. The plant-damage ratio of Pinus thunbergii was $52.48\%$ in the coal storage area, and $8.48\~ 11.52\%$, in the other survey areas. Also, the vitality of Pinus thunbergii was $15.45k{\Omega}$ in the coal storage areas, which indicates bad growing conditions. This suggests that soil characteristics and dust have a bad impact on growth. The investigation into deciduous tres' growth status showed that appropriate plants would be Albizzia julibrissin, Acer palmatum var. sanguineum, Acer palmatum, Malus spp., Prunus sargentii.

Effects of porous pavement on runoff reduction in Boguang subcatchment (투수성 포장도로 도입을 통한 보광배수유역 유출량 저감효과 검토)

  • Jung, Jiyun;Lee, Gunyoung;Ryu, Jaena;Ohe, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.251-259
    • /
    • 2013
  • Among various Green Infrastructure measures for urban stormwater management, effects of porous pavement were quantitatively examined in terms of hydrological cycle. Different scenarios for porous pavement were introduced on a SWMM model and the effects were compared and analysed using discharge hydrographs. Two types of pavements having different runoff coefficients (0.05 & 0.5) were introduced to cover different ratio of entire road areas (100 %, 77.5 % and 40.4 %) and these made up in total 6 different scenarios. Total runoff volume was reduced and peak flow was significantly decreased by applying the porous pavement. The highest reduction for total runoff was shown from S-6(covering area: 100 %, runoff coefficient: 0.05) as 19 % followed by S-5(covering area: 77.5 %, runoff coefficient: 0.05, 16 %), while that of S-2(covering area: 40.4 %, runoff coefficient: 0.05) and S-1(covering area: 40.4 %, runoff coefficient: 0.5) were the lowest with 8 % and 5 %. This proved that the application of porous pavement would improve urban hydrological cycle.

Study on Method of Measurement for Stress-Easing Viewing Urban Greenery

  • Yamamoto, Satoshi;Iwasaki, Yutaka
    • Proceedings of the Korean Institute of Landscape Architecture Conference
    • /
    • 2007.10b
    • /
    • pp.84-88
    • /
    • 2007
  • When people recognize a landscape, they first need to see it for a definite period time. This study clarified the way green space in a landscape is recognized using eye movement analysis, and evaluated the Pffi9bility for quantifying stress-reducing effects of seeing a landscape. The results of the experiments on eye movement analysis suggest that the way of recognizing green space in a landscape may depend on a ratio of the amount of scenic greenery in a landscape, color and greenery layout. Especially, this study also suggests that the possibility of the greenery layout guiding eye movement could be verified by conducting a study on planting patterns. In addition, the results of the experiments for quantifying stress-reducing substances found that it is likely that a green space in an urban area has stress-reducing effects.

  • PDF