• 제목/요약/키워드: Green Air Conditioning

검색결과 102건 처리시간 0.03초

농촌지역 재생에너지 지원 사업 실태 분석 (An Analysis on the Supporting Projects of Renewable Energy for Rural Area)

  • 박용규;김재엽
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.234-235
    • /
    • 2013
  • Recently, interest in renewable energy is rising in rural areas in order to reduce heating and air-conditioning costs which are directly connected to farmhouse income. Thus, in this paper, I study renewable energy supporting projects in rural area: I analyze distribution of the Agriculture & Fishery Energy use Efficiency Project and 1 Million the Green Homes program by using project performance data and the data of Korea Energy Handbook. The results of my analysis of the two programs show that, while annual average increase of the 1 million Green homes prgram is 15.6%, the distribution rate of heating and air-conditioning facilities using geothermal heating and cooling system of the project has decreased by average 37% every year.

  • PDF

신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구 (The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment)

  • 이윤규;신철웅
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.606-611
    • /
    • 2013
  • In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

실내 부하조건에 따른 바닥공조 시스템의 에너지 성능 평가 (An Energy Performance Evaluation of UFAD System under the Various Conditions of Thermal Load)

  • 윤성훈;장향인;김경아;유기형;서승직
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.14-19
    • /
    • 2013
  • The present study has been conducted for evaluating and comparing the performance of the underfloor air distribution system(UFAD) and the ceiling based air distribution system(CBAD) under cooling condition. Simulations and experiments were carried out for verifying the model by TRNSYS program about UFAD and CBAD. The results of simulation for various conditions of thermal load are summarized as followings. UFAD had an advantage for making thermal comfort because of lower temperature of the floor surface. Moreover, UFAD showed lower fan power about 30~50% than CBAD under the same conditions of thermal load. The energy saving rates of UFAD were increased to 17.7% in proportion to the thermal load on unoccupied zone(lighting). Ultimately, additional investigations should be done for analyzing optimized operating conditions of UFAD with considering the thermal performance of building envelop and the thermal load.

지하공기열 히트펌프 제습기에 관한 실험적 연구 (An Experimental Study on a Heat Pump with Dehumidification Function that Utilizes Underground Air Heat)

  • 고지운;박윤철;고광수
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.55-60
    • /
    • 2014
  • The present study has been conducted to develope a heating system for a green house with heat from underground air at Jeju Island. The temperature of the air deposited in the underground is $16{\sim}18^{\circ}C$ throughout the year, and it also has a large amount of moisture. Therefore, the air could not directly used for the heating of a green house. In this study, a heat pump with dehumidification function has been developed, which consisted of three evaporators, where the moisture removal occurs, accompanied by temperature drop. The dropped temperature is recovered, while passing through a series condenser. The air temperature increased from $17^{\circ}C$ to 35 with a 2.1 kg/h of moisture removal rate. The developed system moisture removal performance shows 0.91 kg/kWh.

에어컨용 냉매 HFC-152a와 HFC-152a에 $CF_3$I를 혼합한 공비혼합냉매 특성에 관한 연구 (A Study on the Refrigerant Characteristics of the HFC-l52a, and Azeotrope Mixed with $CF_3$I in Air Conditioners)

  • 이종인;하옥남;홍경한;권일욱;박찬수
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.332-340
    • /
    • 2002
  • In these days, environmental concerns have been increased throughout the industry and community worldwide. To prevent the ozone depletion, ozone depletion potential of a refrigerant must be zero. Simultaneously, a refrigerant with low GWP (global warming potential) is very demanding to induce green house effect. Chlorine-free HFC-l34a is a refrigerant widely used for automotive air-conditioning system because its destruction potential is ecologically zero. Although HFC-l34a has no ozone depletion potential, its global warming potential is so high that it is not considered as a perfect alternative refrigerant that is acceptable for long-term use. In this paper, experimental measurement has been carried out to analyze the performance characteristics of automotive air-conditioning system using HFC-152a, which has low GWP and zero ODP. Also mixed refrigerant that is composed of HFC-152a and $CF_3$ was applied to investigate an alternative possibility for the automotive airconditioning system. As a result of this study, we could draw following conclusions; With respect to the variation of the rotational speed of compressor, outside air temperature and flow rate, the heat amount of evaporator and compressor and performance coefficient was varied.

기존 설계기준 아파트와 친환경 저에너지 아파트의 $LCCO_2$ 비교 ($LCCO_2$ Comparison of Existing Apartment Housing and Environment-Friendly Apartment Housing)

  • 김유민;손장열
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.234-240
    • /
    • 2010
  • In October 2009, the Ministry of Land Transport and Maritime Affairs noticed 'Environment-friendly housing construction standards and performance' to build energy saving environment-friendly housings (Green Homes) for the reduction of energy consumption and carbon dioxide emission. In this study, the $CO_2$ emissions were evaluated during the life cycle of the existing apartments which were built in 1980's and Green Home apartment. $LCCO_2$ was evaluated by dividing the life cycle into three stages which are construction, maintenance and destruction stage. $CO_2$ emission from the materials for improving insulation performance was estimated by Input-output analysis. As a result, in 40 year-life cycle of $84\;m^2$ apartment, 400.68 T-$CO_2$ was emitted from 1980's apartment, on the other hand 231.02 T-$CO_2$ was emitted from Green Home apartment.

포물면 집광거울 방식의 태양광 집광채광시스템 개발 (Development of Solar Daylighting System Using Parabolic Mirrors)

  • 성태경;이충식;김종민;정채봉;김병철
    • 설비공학논문집
    • /
    • 제25권5호
    • /
    • pp.240-245
    • /
    • 2013
  • We developed a parabolic reflector based daylighting system which can be used as an alternative indoor daytime lighting device such as for fluorescent lamps. The system comprises three main components : a daylight concentrator made of 4 pairs of parabolic reflectors and mirrors, a silica optical fiber bundle based light transmitter, and 4 light diffusers for the final indoor delivery of the collected daylight. We analyzed the performance of the system and revealed the system efficiency and daylighting factor. All test methods follow the rule, NR PV601 : 2007-daylighting system, governed by Korea Energy Management Corporation.

건축용 단열재의 장기 경시변화에 따른 열성능 특성 (The Thermal Performance of Building Insulation Materials According to Long-Term Aging)

  • 최보혜;강재식
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.617-623
    • /
    • 2013
  • This study is to draw thermal property data during long-term aging, by testing the thermal conductivity of building insulation materials in Korea. The thermal resistance of extruded insulation within 3 days from manufacture performed well over the KS Standard. After 50 to 110 days, however, the thermal performance had deteriorated to the level of the KS standard. Eventually, after 4,000 days, the insulation performance had deteriorated to about 25.4~41.8% of the initial performance. Therefore, this research will be utilized as a reference for thermal properties during long-term aging, in order to improve standards and regulations related to building insulation materials.

가구류 제품의 시험방법간 상관성 분석 연구 (Development of Correlation Analysis on the Test Methods of Furniure-like Products)

  • 김수하;이윤규;서영민
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.679-684
    • /
    • 2013
  • Hazardous chemicals emitted from building materials and furniture have led to social problems such as sick house syndrome. Test methods for the evaluation of pollutant emissions from furniture-like products have been applied using various national and international standards and classifications, but they are not currently unified. This research has been done to organize the various standards and certification methods and to make new classification systems. Proper test methods have been proposed, tested, and analyzed through this research.

학교시설 친환경건축물인증 사례를 통한 토지이용 및 교통 평가항목 분석 (A Study on the Land Use and Transport of Education Facilities in Green Building Certification Criteria)

  • 권영철;곽문근;최창호
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.589-598
    • /
    • 2010
  • The purpose of this study is to analyze 40 certified Education facilities and to find the way to acquire high scores and usefully method. As a result of analyzing the scores of 40 cases, We found the reasons why they had acquired low scores and high scores. Because the part of land use and transport is initial of the projects, this study focus on it and aim to pick out the items requiring improvement for the Education facilities. We expect to be helpful for the next design works through results of this study.