• Title/Summary/Keyword: Grease removal

검색결과 9건 처리시간 0.02초

하수처리장의 유지제거에 대한 연구 (A Study on the Removal of Grease and Oill in the Treatment Plant)

  • 박재효
    • 한국환경보건학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • ;;김영민;오승진;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

주방환기용 그리스 필터의 성능예측 (Performance Prediction of a Grease Filter for Kitchen Ventilation)

  • 김기정;배귀남;김영일;허남건
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.313-316
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^{3}/h$. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and $100m^{3}/h$. The particle collection efficiency of a grease filter increases with increasing the particle diameter and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter The cut-off diameter of the tested grease filter representing $50-{\%}$ collection efficiency is about $11.6{\mu}m$ for water droplets at $100m^{3}/h$.

  • PDF

주방환기용 그리스 필터의 입자포집 특성에 관한 수치해석 (A Numerical Study on the Particle Collection Characteristics of a Grease Filter for Kitchen Ventilation)

  • 김기정;배귀남;김영일;허남건
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.792-800
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^3$/h. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The air velocity and pressure distributions were discussed in detail. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and 100㎥/h. The particle collection efficiency of a grease filter increases with increasing the particle diameter, the particle density, and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter. The cut-off diameter of the tested grease filter representing 50-% collection efficiency is about 11.6$\mu$m for water droplets at $100m^3$/h.

주방환기용 그리스 필터의 형상설계에 관한 수치해석 (A Numerical Study on the Design of a Grease Filter for Kitchen Ventilation)

  • 김기정;배귀남;김영일;허남건
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.619-629
    • /
    • 2003
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. Since the inertial impaction is a dominant particle removal mechanism of the grease filter, the performance of the filter is greatly affected by the geometry. This numerical study has been conducted to investigate the effect of geometry on the performance of grease filters for four models having nominal flowrate of 100 m$^3$/h. Four models were designed by changing the shape of impaction surface, the length of eyelid, and the number of eyelids of the grease filter. The flow field and particle trajectories in the grease filter with a flow chamber were simulated using the commercial code of STAR-CD. The difference of air velocity and pressure distributions among four models was discussed in detail. The collection efficiency curves and the pressure drops of four models were also compared. It was found that the grease filter model with flat top surfaces shows highest performance among four models, having high particle collection efficiency and relatively low pressure drop. The cutoff diameter of this model representing 50-% collection efficiency is about 7.1 ${\mu}{\textrm}{m}$ for water droplets at 100 m$^3$/h.

Degradation of Fat, Oil, and Grease (FOGs) by Lipase-Producing Bacterium Pseudomonas sp. Strain D2D3

  • Shon, Ho-Kyong;Tian, Dan;Kwon, Dae-Young;Jin, Chang-Suk;Lee, Tae-Jong;Chung, Wook-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권4호
    • /
    • pp.583-591
    • /
    • 2002
  • Biodegradation of fat, oil, and grease (FOGs) plays an Important role in wastewater management and water pollution control. However, many industrial food-processing and food restaurants generate FOG-containing waste waters for which there Is no acceptable technology for their pretreatment. To solve these problems, this study evaluated the feasibility of effective FOG-degrading microorganisms on the biodegradation of olive oil and FOG-containing wastewater. Twenty-two strains capable of degrading FOGs were isolated from five FOG-contaminated sites for the evaluation of their FOG degradation capabilities. Among twenty-two strains tested, the lipase-producing Pseudomonas sp. strain D2D3 was selected for actual FOG wastewater treatment. Its biodegradability was performed at 3$0^{\circ}C$ and pH 8. The extent of FOG removal efficiency was varied for each FOG tested, being the highest for olive oil and animal fat (94.5% and 94.4%), and the lowest for safflower oil (62%). The addition of organic nitrogen sources such as yeast extract, soytone, and peptone enhanced the removal efficiency of FOGs, but the addition of the inorganic nitrogen nutrients such as $NH_4$Cl and $(NH_4)_2SO_4$ did not increase. The $KH_2PO_4$ sources in 0.25% to 0.5% concentrations showed more than 90% degradability. As a result, the main pathway for the oxidation of fatty acids results in the removal of two carbon atoms as acetyl-CoA with each reaction sequence: $\beta$-oxidation. Its lipase activity showed 38.5 U/g DCW using the optimal media after 9 h. Real wastewater and FOGs were used for determining the removal efficiency by using Pseudomonas sp. strain D2D3 bioadditive. The degradation by Pseudomonas sp. strain D2D3 was 41% higher than that of the naturally occurring bacteria. This result indicated that the use of isolated Pseudomonas sp. strain D2D3 in a bioaugmentating grease trap or other processes might possibly be sufficient to acclimate biological processes for degrading FOGs.

음식물류 폐수를 이용한 바이오가스 생산시설의 스케일 형성요인에 관한 연구 (A Study on the Cause of Scale Formation in Biogas Plant with Food Wastewater)

  • 배영신;천승규
    • 대한환경공학회지
    • /
    • 제35권9호
    • /
    • pp.660-665
    • /
    • 2013
  • 소화설비내 스케일 형성의 주요 원인을 파악하기 위하여 스케일 성분분석 및 음식물류 폐수에 대한 혐기소화 실험을 하였다. 성분분석결과, 음식물류 폐수 중 유분이 스케일의 유기성분과 밀접한 연관이 있었다. 또한, 소화실험시 소화조내 결정체의 발생량은 음식물류 폐수중 유분을 사전에 제거한 경우가 제거하지 않은 원수를 소화한 경우의 58.9% 수준으로 나타나 유분이 스케일 형성의 중요한 요인임을 알 수 있었다. 아울러, 유분을 제거한 음식물류 폐수는 68.7 L-gas/kg-COD 그리고 음식물류 폐수 원수는 67.7 L-gas/kg-COD로서 유분의 사전제거가 소화가스 생산에 부정적 영향을 주지 않았다.

전해액의 Fe 농도에 의한 크롬도금 탈락 연구 (Study On Effect of Fe Density on Electrolyte Exfoliation of Chromium Plating Layer)

  • 박진생
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1297-1303
    • /
    • 2015
  • 장축의 내부 크롬도금은 크롬산 용액에 황산을 촉매로 경질의 후막 도금층을 형성시키는 기술로서 산업뿐만 아니라 군사적 목적으로도 널리 사용되고 있다. 대구경의 포신내부에 경질크롬도금을 처리하면 강성과 내마성을 증대시켜 고압의 폭발력에 견딜 수 있다. 탄자의 높은 운동에너지와 탄 폭발로 생긴 고압력에 의해 포신 내부의 크롬도금층이 탈락되는 문제가 있어 도금 공정 전반에 걸친 검토가 이루어졌다. 크롬도금은 탈지, 수세, 전해연마, 에칭, 도금, 수세 및 수소취성제거 등 여러 공정으로 이루어진다. 크롬도금 탈락은 도금의 밀착성과 연관이 있으며, 그 중에 전해연마액의 Fe 농도가 도금 밀착성에 영향을 미치는 것으로 나타났다. 도금부위의 요철상태를 SEM으로 조사하여 도금탈락을 방지할 수 있는 최적의 Fe 농도를 설정하고, 밀착성 시험 등으로 그 효과를 입증하였다.

철도부지 오염도상자갈의 건식 정화 기술 성능 연구 (Study of the Performance of a Dry Cleaning Method for Polluted Ballast Gravel of Railroad Fields)

  • 조영민;박덕신;권태순;이재영
    • 한국철도학회논문집
    • /
    • 제18권6호
    • /
    • pp.552-557
    • /
    • 2015
  • 철도부지의 도상자갈은 윤활유, 중금속 등으로 오염된 경우가 많다. 이에 본 연구에서는 오염된 자갈표면의 오염물질을 물리적으로 제거하는 오염도상자갈의 건식 정화 기술 성능을 알아보고자 하였다. 오염도상자갈 표면에 경도가 높은 금강사 연마재를 압축공기를 이용하여 분사할 수 있는 오염자갈 정화 장치를 제작하고, 여기에 오염자갈을 투입하여, 처리 시간을 1~10분까지 다양하게 변화시키면서 도상자갈의 석유계총탄화수소와 중금속 등의 정화 효율을 알아보았다. 석유계총탄화수소 제거 효율은 기관차 정차장에서 포집한 차량 윤활유 오염자갈은 70-80%로 다소 높은 반면에, 분기기에서 포집한 분기기 윤활유 오염자갈은 40-60%로 비교적 낮았다. 중금속 제거 효율은 구리와 납이 90% 이상으로 높은 반면에 니켈과 아연은 65-80%로 비교적 낮았다. 실험 결과 건식 자갈 정화 기술은 오염자갈의 처리에 효율적임을 확인할 수 있었다.