• Title/Summary/Keyword: Gray Image

Search Result 1,032, Processing Time 0.028 seconds

A Driver's Condition Warning System using Eye Aspect Ratio (눈 영상비를 이용한 운전자 상태 경고 시스템)

  • Shin, Moon-Chang;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.349-356
    • /
    • 2020
  • This paper introduces the implementation of a driver's condition warning system using eye aspect ratio to prevent a car accident. The proposed driver's condition warning system using eye aspect ratio consists of a camera, that is required to detect eyes, the Raspberrypie that processes information on eyes from the camera, buzzer and vibrator, that are required to warn the driver. In order to detect and recognize driver's eyes, the histogram of oriented gradients and face landmark estimation based on deep-learning are used. Initially the system calculates the eye aspect ratio of the driver from 6 coordinates around the eye and then gets each eye aspect ratio values when the eyes are opened and closed. These two different eye aspect ratio values are used to calculate the threshold value that is necessary to determine the eye state. Because the threshold value is adaptively determined according to the driver's eye aspect ratio, the system can use the optimal threshold value to determine the driver's condition. In addition, the system synthesizes an input image from the gray-scaled and LAB model images to operate in low lighting conditions.

Model-based Dithering Using Dot Pattern Selection (도트 패턴 선택을 이용한 모델 기반 디더링)

  • Lee, Chae-Soo;Park, Yang-Woo;Uam, Tae-Uk;Jang, Joo-Seok;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.3
    • /
    • pp.247-257
    • /
    • 2001
  • New methods are proposed for printing a full resolution image on a limited output device. The proposed algorithm uses a dot-pattern database that models overlapping phenomena among neighbor printing dots. To solve the problem of dot-overlap, the gray levels of dot-pattern sets were calculated using a circular dot-overlap model and then measured by a spectrometer. Thereafter, in order to improve the visual quality of the color dithering, the contrast sensitivity function of the human visual system was used. As a result, the optimal dot-pattern can be selected from the database. Consequently, the proposed algorithm can produce high quality images while using low-cost color devices.

  • PDF

Aerosol-extinction Retrieval Method at Three Effective RGB Wavelengths Using a Commercial Digital Camera (상용 디지털 카메라를 이용한 3가지 유효 RGB 파장에서의 미세먼지 소산계수 산출법)

  • Park, Sunho;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.2
    • /
    • pp.71-80
    • /
    • 2020
  • In this article, we suggest a new method for measuring an aerosol's extinction coefficient using a commercial camera. For a given image, we choose three pixel-points that are imaged for the same kinds of objects located in similar directions. We suggest and calculate aerosol extinction coefficients from these RGB gray levels and the different distances of the three objects. To compare our measurement results, we also measure extinction coefficients using lidar. Finally, we find that there are meaningful and sensible correlations between these two measurements, with a correlation coefficient of 0.86. We measure the aerosol extinction coefficient at three different RGB wavelengths using the same method. From these aerosol extinction coefficients at three different wavelengths, we find that the Angstrom exponent ranges from 0.7 to 1.6 over a full daytime period. We believe that these Angstrom exponents can give important information about the size of the fine particles.

Efficient Compression of MR Images Using Fractal Coding in Wavelet Transform Domain (웨이브릿 변환 영역에서의 프랙탈 부호화를 이용한 효율적 MR 영상 압축)

  • Bae S.H.;Yoon O.K.;Kim J.H.;Park C.H.;Lee S.K.;Park K.H.;Kim H.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.247-254
    • /
    • 2000
  • We propose an efficient MR image compression technique using fractal coding in wavelet transform domain. In the Proposed method , we construct significant coefficient trees with the absolute values of discrete wavelet transform coefficients and then perform the fractal coding with the information of significant coefficients having high energy. For MR images, most Pixels including background have very low gray level values, the number of significant coefficients is small. so we can expect high compression rate. In addition. since this method uses the fractal coding in wavelet transform domain, blocking artifact is reduced prominently and edges sensitive to human visual system are well preserved. As a result of computer simulation, we obtained the reconstructed images with better quality than those by JPEG at the low bit rates below 0.33[bpp].

  • PDF

A Study on the Discharge Characteristics of High Speed Addressing for the HDTV Class Plasma Display (HDTV급 플라즈마 디스플레이의 고속 어드레스 방전특성에 관한 연구)

  • 염정덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.13-21
    • /
    • 2001
  • The discharge characteristics of 3 electrcdes AC surface discharge plasma display were analyzed. For an unstable state of the discharge which appeared at the maximum discharge voltage, it is found that a parbal erase of the wall charge by the second discharge is a cause. Based on the second discharge, new operation margin considering the interrelation between the address discharge and the display discharge was defined and the validity of it was verified by the experiments. It is necessary to decrease the acklress pulse width for high-speed addressing. However, the operation margin of the ackIress pulse decreases as the pulse width of it becomes narrower. If the address pulse width is wider than l[ps], the operation margin of the display discharge is not related to the address pulse width. From the experimental result, image or 8bit 253 gray level was displayed on PDP with the cell structure of the HDTV class by using the high-speed address ADS drive methcd with pulse width of $1[{\mu}s]$ and the brightness of $560[cd/m^2]$ was obtained. ained.

  • PDF

Shadow Classification for Detecting Vehicles in a Single Frame (단일 프레임에서 차량 검출을 위한 그림자 분류 기법)

  • Lee, Dae-Ho;Park, Young-Tae
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.11
    • /
    • pp.991-1000
    • /
    • 2007
  • A new robust approach to detect vehicles in a single frame of traffic scenes is presented. The method is based on the multi-level shadow classification, which has been shown to have the capability of extracting correct shadow shapes regardless of the operating conditions. The rationale of this classification is supported by the fact that shadow regions underneath vehicles usually exhibit darker gray level regardless of the vehicle brightness and illuminating conditions. Classified shadows provide string clues on the presence of vehicles. Unlike other schemes, neither background nor temporal information is utilized; thereby the performance is robust to the abrupt change of weather and the traffic congestion. By a simple evidential reasoning, the shadow evidences are combined with bright evidences to locate correct position of vehicles. Experimental results show the missing rate ranges form 0.9% to 7.2%, while the false alarm rate is below 4% for six traffic scenes sets under different operating conditions. The processing speed for more than 70 frames per second could be obtained for nominal image size, which makes the real-time implementation of measuring the traffic parameters possible.

Surface Rendering in Abdominal Aortic Aneurysm by Deformable Model (복부대동맥의 3차원 표면모델링을 위한 가변형 능동모델의 적용)

  • Choi, Seok-Yoon;Kim, Chang-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.266-274
    • /
    • 2009
  • An abdominal aortic aneurysm occurs most commonly in older individuals (between 65 and 75), and more in men and smokers. The most important complication of an abdominal aortic aneurysm is rupture, which is most often a fatal event. An abdominal aortic aneurysm weakens the walls of the blood vessel, leaving it vulnerable to bursting open, or rupturing, and spilling large amounts of blood into the abdominal cavity. surface modeling is very useful to surgery for quantitative analysis of abdominal aortic aneurysm. the 3D representation and surface modeling an abdominal aortic aneurysm structure taken from Multi Detector Computed Tomography. The construction of the 3D model is generally carried out by staking the contours obtained from 2D segmentation of each CT slice, so the quality of the 3D model strongly defends on the precision of segmentation process. In this work we present deformable model algorithm. deformable model is an energy-minimizing spline guided by external constraint force. External force which we call Gradient Vector Flow, is computed as a diffusion of a gradient vectors of gray level or binary edge map derived from the image. Finally, we have used snakes successfully for abdominal aortic aneurysm segmentation the performance of snake was visually and quantitatively validated by experts.

Optical Encryption of Binary Information using 2-step Phase-shifting Digital Holography (2-단계 위상 천이 디지털 홀로그래피를 이용한 이진 정보 광 암호화 기법)

  • Byun, Hyun-Joong;Gil, Sang-Keun
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.401-411
    • /
    • 2006
  • We propose an optical encryption/decryption technique for a security system based on 2-step phase-shifting digital holography. Phase-shilling digital holography is used for recording phase and amplitude information on a CCD device. 2-step phase-shifting is implemented by moving the PZT mirror with phase step of 0 or ${\pi}/2$. The binary data and the key are expressed with random code and random phase patterns. The digital hologram is a Fourier transform hologram and is recorded on CCD with 256 gray level quantization. We remove the DC term of the digital hologram fur data reconstruction, which is essential to reconstruct the original binary input data/image. The error evaluation fer the decrypted binary data is analyzed. One of errors is a quantization error in detecting the hologram intensity on CCD, and the other is generated from decrypting the data with the incorrect key. The technique using 2-step phase-shifting holography is more efficient than a 4-step method because 2-step phase-shifting holography system uses less data than the 4-step method for data storage or transmission. The simulation shows that the proposed technique gives good results fur the optical encryption of binary information.

Pavement Crack Detection and Segmentation Based on Deep Neural Network

  • Nguyen, Huy Toan;Yu, Gwang Hyun;Na, Seung You;Kim, Jin Young;Seo, Kyung Sik
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.9
    • /
    • pp.99-112
    • /
    • 2019
  • Cracks on pavement surfaces are critical signs and symptoms of the degradation of pavement structures. Image-based pavement crack detection is a challenging problem due to the intensity inhomogeneity, topology complexity, low contrast, and noisy texture background. In this paper, we address the problem of pavement crack detection and segmentation at pixel-level based on a Deep Neural Network (DNN) using gray-scale images. We propose a novel DNN architecture which contains a modified U-net network and a high-level features network. An important contribution of this work is the combination of these networks afforded through the fusion layer. To the best of our knowledge, this is the first paper introducing this combination for pavement crack segmentation and detection problem. The system performance of crack detection and segmentation is enhanced dramatically by using our novel architecture. We thoroughly implement and evaluate our proposed system on two open data sets: the Crack Forest Dataset (CFD) and the AigleRN dataset. Experimental results demonstrate that our system outperforms eight state-of-the-art methods on the same data sets.

Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: An in vitro study

  • Juliana Andrea Correa, Travessas;Alessandra Mendonca, dos Santos;Rodrigo Pagliarini, Buligon;Nadia Assein, Arus;Priscila Fernanda Tiecher, da Silveira;Heraldo Luis Dias, da Silveira;Mariana Boessio, Vizzotto
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.399-408
    • /
    • 2022
  • Purpose: The purpose of this study was to compare volume measurements obtained using 2 image software packages on Digital Imaging and Communications in Medicine (DICOM) images acquired from 1 multidetector computed tomography and 5 cone-beam computed tomography devices, using different protocols for physical volume measurements. Materials and Methods: Four pieces of bovine leg were prepared. Marrow was removed from 3 pieces, leaving cortical bone exposed. The resulting space of 1 piece was filled with water, another was filled with propylene glycol, and the third was left unfilled. The marrow in the fourth sample was left fully intact. Volume measurements were obtained after importing DICOM images into the Dolphin Imaging 11.95 and ITK-SNAP software programs. Data were analyzed using 3-way analysis of variance with a generalized linear model to determine the effects of voxel size, software, and content on percentage mean volume differences between tomographic protocols. A significance level of 0.05 was used. Results: The intraclass correlation coefficients for intraobserver and interobserver reliability were, respectively, 0.915 and 0.764 for the Dolphin software and 0.894 and 0.766 for the ITK-SNAP software. Three sources of statistically significant variation were identified: the interaction between software and content (P=0.001), the main effect of content (P=0.014), and the main effect of software (P=0.001). Voxel size was not associated with statistically significant differences in volume measurements. Conclusion: Both content and software influenced the accuracy of volume measurements, especially when the content had gray values similar to those of the adjacent tissues.