• Title/Summary/Keyword: Gravel Compaction Pile

Search Result 26, Processing Time 0.025 seconds

A Comparative Study on the Effect of Promoting Consolidation between SCP and GCP (SCP와 GCP의 압밀촉진효과에 관한 비교 고찰)

  • You, Seung-Kyong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.2
    • /
    • pp.41-46
    • /
    • 2009
  • In this paper, a series of model tests were performed in laboratory to evaluate promoting consolidation of compaction pile methods for soft ground improvement. For the model tests, composite soil samples that have 10% replacement area ratio were prepared by using sand, gravel, and sandy gravel for the materials of compaction piles. After loading to each composite soil sample, the excess pore pressure dissipation and settlement were investigated. In addition, the behavior of clay mixed with each compaction pile was also monitored at the end of consolidation to evaluate clogging phenomenon. As a test result, the effects for decreasing settlement and promoting consolidation by GCP were prominent, and the mixed clay was not monitored in all of the three compaction piles.

  • PDF

The Characteristics on Infiltration of Fine-Grained Soil into Various Materials for Ground Drainage (지반 배수재에 따른 세립토의 관입특성)

  • Koh, Yongil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.11
    • /
    • pp.39-43
    • /
    • 2015
  • In this study, the infiltration quantity of fine-grained soil into coarse-grained soil or aggregate for methods to accelerate consolidation drainage is checked by laboratory tests under various conditions and those characteristics on infiltration are examined closely. Irrespectively of pressures to fine-grained soil corresponding to stresses in a soil mass or moisture contents of fine-grained soil, fine-grained soil does not infiltrate into standard sand and marine sand, so it is verified that drain-resistance into sand mass of drainage / pile does not occur entirely and its shear strength would increase highly by water compaction. It is known that the infiltration depth of fine-grained soil into aggregate increases according that those size is larger in case of aggregates and it increases according that the pressure or the moisture contents is higher in case of same size aggregate. It is thought that drain-resistance into aggregate mass of drainage / pile would occurs by infiltrated fine-grained soil in advance though the infiltration depth of fine-grained soi of lower moisture content than liquid limit into 13 mm aggregate is low quietly. So gravel drain method or gravel compaction pile method, etc. using aggregate of gravels or crushed stones, etc. larger than sand particle size should be not applied in very soft fine-grained soil mass of higher natural moisture contents than liquid limit, and it is thought that its applying is not nearly efficient also in soft fine-grained soil mass of lower natural moisture contents than liquid limit.

Numerical Study of Settlement Reduction Ratio for the Bottom Ash Mixture Compaction Pile (수치해석적 방법에 의한 저회혼합다짐말뚝의 침하저감비에 관한 연구)

  • Chu, Ickchan;Kim, Gooyoung;Do, Jongnam;Cho, Hyunsoo;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.53-58
    • /
    • 2012
  • In general, sand compaction pile(SCP) method and gravel compaction pile(GCP) method have been mainly used to reinforce soft soils such as soft clay or loose sandy ground. But the sand compaction pile method has problems such as lack of sand supply and destroying the nature while collecting sand, the gravel compaction pile method has a problem such as decreased permeability of the drainage material due to clogging. Recently, the study to replace sand with bottom ash which has similar engineering properties with sand is in active. As a fundamental research on bottom ash mixture compaction pile utilizing bottom ash, its behavioral characteristics depending on granular materials and replacement ratio has been simulated numerically. In particular, Settlement Reduction Ratio(SRR) according to the distance from the center of pile was calculated. The main findings were as follows. Change values of Mixture Compaction Pile's SRR according to granular materials showed similar patterns and stiffness of the composite soil is increased depending on the replacement ratio so SRR showed decreased patterns. Especially, when the replacement ratio is in 20~40%, it increase significantly. When the replacement ratio is over 40%, it increase slowly. When considering the economics, 30~40% replacement ratio is appropriate.

Finite Element Analysis for Investigating the Behavior of Gravel Compaction Pile Composite Ground (GCP 복합지반의 거동분석을 위한 유한요소해석)

  • Kim, Gyeong-eop;Park, Kyung-Ho;Kim, Ho-Yeon;Kim, Daehyeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.3
    • /
    • pp.19-32
    • /
    • 2018
  • Gravel Compaction Pile (GCP) method is currently being designed and constructed by empirical method because quantitative design method has not been developed, leading to various types of and frequent destruction such as expansion failure and shear failure and difficulties in establishing clear cause and developing measure to prevent destruction. In addition, despite the difference with domestic construction equipment and material characteristics, the methods applied to the overseas ground is applied to the domestic as it is, leading to remarkable difference between applied values and measured values in variables such as bearing capacity and the settlement amount. The purpose of this study was, therefore, to propose a reasonable and safe design method of GCP method by analyzing the settlement and stress behavior characteristics according to ground strength change under GCP method applied to domestic clay ground. For the purpose, settlement amount of composite ground, stress concentration ratio, and maximum horizontal displacement and expected location of GCP were analyzed using ABAQUS. The results of analysis showed that the settlement and Settlement reduction rate of composite ground decreased by more than 60% under replacement ratio of 30% or more, that the maximum horizontal displacement of GCP occurred at the depth 2.6 times pile diameter, and that the difference in horizontal displacement is slight under replacement ratio of 30%.

Evaluation of Ultimate Bearing Capacity on Granular Compaction Pile Considering Various Stresses in a Ground (지중응력의 변화를 고려한 조립토 다짐말뚝의 극한지지력 평가)

  • Kang, Yun;Yun, Ji-Yeon;Chang, Weon-Ho;Kim, Hong-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.2
    • /
    • pp.115-124
    • /
    • 2004
  • Granular compaction pile has the load bearing capacity of the soft ground increase and has the settlement of foundation built on the reinforced soil reduce. The granular compaction group piles also have the consolidation of the soft ground accelerate and prevent the liquefaction caused by earthquake using the granular materials such as sand, gravel, stone etc. However, this method is not widely used in Korea. The granular compaction piles are constructed by grouping them with a raft system. The confining pressure at the center of bulging failure depth is a major variable in estimating the ultimate bearing capacity of the granular compaction piles. Therefore, a share of loading is determined considering the effect of load concentration ratio between the granular compaction piles and surrounding soils, and the variation of the magnitude of the confining pressure. In this study, a method for the determination of the ultimate bearing capacity is proposed to apply a change of the horizontal pressure considering bulging failure depth, surcharge, and loaded area. Also, the ultimate bearing capacity of the granular compaction pile is evaluated on the basis of previous study(Kim et al., 1998) on the estimation of the ultimate bearing capacity and compared with the results obtained from laboratory scale model tests and DEM numerical analysis using the PFC-2D program.

Estimation of Ultimate Bearing Capacity for Randomly Installed Granular Compaction Pile Group (임의의 배치형태로 설치된 무리형태의 조립토 다짐말뚝에 대한 극한지지력의 평가)

  • 신방웅;채현식;김홍택
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.181-191
    • /
    • 2001
  • Granular compaction piles increase the load bearing capacity of the soft ground and reduce the settlement of fecundation built on the reinforced soil. Also the granular compaction piles accelerate the consolidation of soft ground using the granular materials such as sand, gravel, stone etc. However, this method is one of unuseful methods in Korea. In the present study, the estimation procedure for the ultimate bearing capacity of randomly installed granular compaction pile group is proposed. Also, carbon rod tests have been peformed for verifying the group effect of granular compaction piles and the behavior characteristics such as bulging failure zone on granular compaction piles. From the test results, it is found that bulging failure shape of granular compaction piles was conical shape and the ultimate bearing capacity increased as the spacing of piles became gradually narrow. Also, from the proposed method in this study, the optimal locations of granular compaction piles with various installed cases are analyzed. The results were shown that the bearing capacity was increased in the case concentrated on the central part of pile group.

  • PDF

Analysis of Bearing Capacity Characteristics on Granular Compaction Pile - focusing on the Model Test Results (조립토 다짐말뚝의 지지력 특성 분석 - 모형토조실험 결과를 중심으로)

  • Kang, Yun;Kim, Hong-Taek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.2
    • /
    • pp.51-62
    • /
    • 2004
  • Granular compaction piles have the load bearing capacity of the soft ground increase and have the settlement of foundation built on the reinforced soil reduce. The granular compaction group piles also have the consolidation of the soft ground accelerate and have the liquefaction caused by earthquake prevent using the granular materials such as sand, gravel, stone etc. However, this method is one of unuseful methods in Korea. The Granular compaction piles are constructed by grouping it with a raft system. The confining pressure at the center of bulging failure depth is a major variable in relation to estimate for the ultimate bearing capacity of the granular compaction piles. Therefore, a share of loading is determined considering the effect of load concentration ratio between the granular compaction piles and surrounding soils, and varies the magnitude of the confining pressure. In this study, method for the determination of the ultimate bearing capacity is proposed to apply a change of the horizontal pressure considering bulging failure depth, surcharge and loaded area. Also, the ultimate bearing capacity of the granular compaction piles is evaluated on the basis of previous study on the estimation of the ultimate bearing capacity and compared with the results obtained from laboratory scale model tests. And using the result from laboratory model tests, it is studied increase effect of the bearing capacity on the granular compaction piles and variance of coefficient of consolidation for the ground.

  • PDF

Centrifuge Modeling on Displacement Shapes of Composite Ground Improved by SCP and GCP (SCP 및 GCP로 개량된 복합지반의 변위 양상에 관한 원심모델링)

  • Heo, Yol;Zheng, Zhaodian;Lee, Cheokeun;Ahn, Kwangkuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.5
    • /
    • pp.57-66
    • /
    • 2006
  • In this study, the centrifuge model tests were carried out to evaluate the stress concentration ratio, the deformation modes of piles and the ground movement in clay deposit improved by SCP and GCP piles with changing the replacement ratio(20%, 40%, 60%) under flexible loading. Based on the results obtained, it was shown that the stresses acting on GCP was larger than those acting on SCP with the same replacement ratio. It was evaluated that the average stress concentration ratio of soft clay ground improved by GCP was slightly larger than that of SCP when the replacement ratio is 40%. Only expansion failure occurred in GCP, whereas SCP showed the expansion and shear failure simultaneously.

  • PDF

Evaluation of Seismic Performance of Quay Walls during Earthquakes (지진동을 받는 안벽 구조물의 내진 성능 평가)

  • 김성렬
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.112-119
    • /
    • 2000
  • the shaking table tests for 5 different model sections are performed to investigate the behaviors of quay walls during earthquakes and to evaluate the seismic performance of quay walls with countermeasures. 5 different model sections describe the cases of dense soil and loose soil in the foundation repectively the case to which gravel backfill was applied and the cases to which light material replacement method and sand compction pile method was applied repectively for sesmic countermeasure methods. Pore water pressures accelerations and deformations in quay walls and grounds are analyzed. As a result the softening of foundation and backfill soils have much influence on the behaviors of quay walls. Also light material replacement method and sand compaction pile method are effective in improving the seismic performance of quay walls.

  • PDF

Centrifugal Model Test on Stress Concentration Behaviors of Composition Ground under Flexible/Stiff Surcharge Loadings (연/강성 하중을 받는 복합지반의 응력분담거동에 대한 원심모형시험)

  • Song, MyungGeun;Bae, WooSeok;Ahn, SangRo;Heo, Yol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.6
    • /
    • pp.5-15
    • /
    • 2011
  • In this study, centrifuge model tests were performed to investigate stress concentration ratio, stress characteristics of soft clay ground improved by granular compaction piles with changes of piles type, loading condition and area replacement ratio. From the results of rigid loading tests, while vertical stresses acting on clay ground is similar, vertical stresses acting on GCP is larger than those acting on SCP with same replacement ratio. Also, average stress concentration ratio is increased proportionally with increasing the area replacement ratio of GCP and SCP. It was evaluated that average stress concentration ratio of soft clay ground improved by GCP is larger than that of SCP. As a result of flexible loading tests, stress concentration ratio is the highest when replacement ratio of GCP and SCP is 40%. Average stress concentration ratio of soft clay ground improved by GCP is a little more higher than is improved by SCP.