• 제목/요약/키워드: Grating Projection

검색결과 27건 처리시간 0.022초

$Moir\acute{e}$ Fringe에 의한 액막 두께 미소 변위 측정 연구 (A Study on the Small Disturbance Measurement of Liquid Film Thickness by $Moir\acute{e}$ Fringe)

  • 전홍신;김경훈
    • 한국분무공학회지
    • /
    • 제2권4호
    • /
    • pp.29-35
    • /
    • 1997
  • Liquid film thickness is measured by $moir\acute{e}$ topography which monitored liquid surface. $Moir\acute{e}$ fringe measurement techniques share the inherent simplicity found in optical interferometric techniques have the advantage of use over a greater range of displacement. $Moir\acute{e}$ fringe are the geometric interference patterns observed when two dense line grating are superposed. Light transmitted through a fixed line grating is deviated by the liquid film surface, producing a distored image of the grating. The $moir\acute{e}$ fringe produced by projection of this optically distored grating onto a second stationary grating permit visualization of the liquid surface and measurement of the liquid film thickness. This study measured the small amplitude of liquid film thickness to the $moir\acute{e}$ fringe pattern produced when spherical metal was dropped glycerin put)1 And the measurement of liquid film thickness flowing down an inclined plate are required to calculate the liquid slope in a position.

  • PDF

PMP 형상 측정법의 위상보정에 관한 연구 (A study on the phase calibration of the phase measuring profilometry)

  • 이연태;강영준;황용선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 2002
  • The 3-D measurement using a sinusoidal grating pattern projection is very attractive because of its high measuring speed and high sensitivity. When a sinusoidal amplitude grating was projected on an object, the surface-height distribution of the object is translated into a phase distribution of the deformed grating image. The phase-acquisition algorithms are so sufficiently simple that high-resolution phase maps using a CCD camera can be generated in a short time. The PMP technique is discussed, and the analysis of the systematic errors, the calibration procedure designed to determined the optimal setting of the measurement parameters is illustrated. Results of measurements and calibrations on the measurement plane objects are described.

  • PDF

Digital moire 형상측정 시스템의 보정에 관한 연구 (A Study on the Calibration of Shape Measurement System Using Digital moire)

  • 유원재;김도훈;안재웅;강영준;노형민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF

인체흉상 합성을 위한 3차원 형상 측정에 관한 연구 (A study on 3-D shape measurement for the composition of human bust)

  • 안중근;강영준;최정표;유원재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.220-223
    • /
    • 1997
  • Moire topography method is a well-known non-contacting 3-D measuement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topography is very attractive because of it's high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the 2x-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the 2x-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

Design of Diffraction Limited Head Mounted Display Optical System Based on High Efficiency Diffractive Elements

  • Tehrani, Masoud Kavosh;Fard, Sayed Sajjad Mousavi
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.150-156
    • /
    • 2017
  • A diffraction limited optical system for head mounted displays (HMDs) was designed. This optical system consists of four modules, including 1:5 mm and 5:30 mm beam expanders, polarization grating-polarization conversion system (PG-PCS) and refractive/diffractive projection optical module. The PG-PCS module transforms the unpolarized Gaussian beam to a linearly polarized beam and it simultaneously homogenizes the spatial intensity profile. The optical projector module has a $30^{\circ}$ field of view, a 22 mm eye relief, and a 10 mm exit pupil diameter with a compact structure. Common acrylic materials were utilized in the optical design process; therefore, the final optical system was lightweight. The whole optical system is suitable for a 0.7 inch liquid crystal on silicon microdisplay (LCOS) with HDTV resolution ($1920{\times}1080$) and $8.0{\mu}m$ pixel pitch.

위상천이 주사격자 영사식 모아레 간섭계를 이용한 초.중학생의 배부체형고찰 (A Study of the Back Shape of the Children in Elementary and Middle Schools Using the Phase-shifting Scanning Grating Projection moire)

  • 유한길;민병일;박동석
    • 대한한의학회지
    • /
    • 제21권4호
    • /
    • pp.148-158
    • /
    • 2000
  • Objective : The purpose of this study was to investigate the back shape of school children using the phase-shifting scanning grating projection moire interferometer, which was developed by the Korea Advanced Institute of Science and Technology and is useful in evaluating three dimensional back shape. Methods : In this study the subjects consisted of 1,358 pupils [711 boys(52.36%), 647 girls(47.64%)] attending elementary and middle schools in Seoul. Their ages ranged from nine to fifteen and the average age was 12.2. With the phase-shifting scanning grating projection moire interferometer, the posterior view of the body were taken to see if there are correlations of moire fringe number, width difference between left and right, and correlation between differences in moire fringe number and width on both sides in the scapular, lumbar and gluteal regions. Results : The results were as follows : I. More frequent findings of fringe were observed on the right in all regions : in the scapular region, 309 boys(43.4%) and 156 girls(24.2%) had more fringe numbers on the right side; in the lumbar region, 68 boys(9.5%) and 11 girls(1.7%); and in the gluteal region, 160 boys(22.4%) and 63 girls(9.8%). Such tendency was striking especially in the scapular and lumbar regions, and in boys rather than in girls. In the scapula, 661 subjects(48.7%) with one moire fringe on either side need further attention and 110 subjects(8.I %) with two or more are required to do follow-up radiography for scoliosis. 2. In an analysis of width difference in the trunk, the left side is wider in all regions except for the gluteal region in boys : in the scapular region 21 boys(3.0%) and 103 girls(15.9%); in the lumbar region, 87 boys(12.2%) and 250 girls(38.6%); and in the gluteal region 197 girls(30.4%) had a wider left side and 45 boys(6.3%) showed a wider right side. 3. In correlation analysis of the number of moire fringe and width difference in each region, the side where more moire fringes were observed was significantly wider in the lumbar and gluteal regions, but not in the scapular region.(p<0.01) Conclusions : From these results, it is concluded that the back shape of elementary and middle school students in Seoul shows that the right side had more moire fringes; the left side was wider; and especially in the lumbar and gluteal regions the side where more moire fringes were observed was wider.

  • PDF

단일격자 이송을 이용한 영사식 3차원 물체 형상 측정에 관한 연구 (A Study on the measurement of 3-D Object with Single Grating Shiftings)

  • 박윤창;정경민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 춘계학술대회 논문집
    • /
    • pp.187-192
    • /
    • 1999
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and its's high sensitivity. Especially when projecting a grid pattern over the object, the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, the projection moire are compared with the PMP mathematically, and it is shown that PMP can generate moire image with simple mathematical computations. Experimental works are also carried out showing the same results. It is shown that using a single gird pattern, moire image can be obtained directly without any mathematical operation when some conditions are satisfied.

  • PDF

Three-dimensional shape measurement using grating patterns form an optical spatial modulator

  • Tsujioka, Katsumi;Ito, Hiroshi;Furuhashi, Hideo;Higa, Shuntaro;Hayashi, Niichi;Yamada, Jun;Hatano, Kazuo;Uchida, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.561-565
    • /
    • 1994
  • An automatic measuring system of three dimensional shape by a projection method with grating pattern from in optical spatial modulator has been developed. The characteristics of the system were studied. This system is composed of a projector, an optical spatial modulator, a CCD camera, and computer. A liquid crystal is used as the optical spatial modulator. The grating patterns that ire projected on the surface of the object are controlled by the computer connected with the optical spatial modulator. The projector patterns are measured by the CCD camera. The data are transferred to the computer. After a transformation into line data, the data are analyzed to obtain the coordinate of the surface of the object. This system has advantages as follows. (1) It is possible to capture the surface topography without any contact. (2) The time required for the measurements is shorter than the light-section method. (3) An optical spatial modulator using a liquid crystal is possible to control the grating patterns accurately by a computer. Surfaces of a plate and a cylinder were measured. The threshold level had an influence on the measurement. It was shown that this system has adequae accuracy in the measurements.

  • PDF

라인스캔 카메라를 이용한 3차원 정밀 측정 (3D Precision Measurement of Scanning Moire Using Line Scan Camera)

  • 김현주;윤두현;김학일
    • 한국광학회지
    • /
    • 제19권5호
    • /
    • pp.376-380
    • /
    • 2008
  • 본 논문에서는 라인스캔 카메라를 통해 모든 영역의 영상을 획득하는 연구를 제안한다. 이 방법은 기존의 면적 카메라를 이용했던 방법에 비해 투영격자의 이동 횟수를 획기적으로 줄일 수 있으며, 그로 인해 측정시간이 매우 빠르고 측정정밀도도 뛰어난 장점을 가진다. 본 논문의 스캐닝 모아레 측정 방법은 넓은 영역의 3차원 형상 정보를 얻는데 매우 유익하며, 대면적의 대상물 측정 시 일반적으로 사용하는 stitching 기법을 사용할 필요가 없으므로 한번에 전 영역의 3차원 형상의 복원이 가능하여 보다 빠른 속도로 3차원 형상 정보를 얻을 수 있는 효과가 있다. 또한, 투영격자 하나만을 이용한 영사식 모아레 방식을 이용하여 작은 높이 단차를 갖는 물체의 3차원 형상을 복원하고 그 높이를 용이하게 측정 할 수 있다. 본 연구는 양산환경(Mass production)의 웨이퍼 범프 높이 검사 및 FC-CSP나 FC-BGA 범프 높이 검사 등에 활용 할 수 있으며, 실험을 통해 기존의 방법에 비해 투영격자의 이동횟수 및 측정 속도가 향상되었음을 확인하였다.

Digital Moire를 이용한 임의의 영사면에 대한 투영보정에 관한 연구 (A Study on Projective Calibration for Arbitrary Display Surface using Digital Moire Method.)

  • 유원재;김도훈;강영준;백성훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 2003
  • Moire topography method is a well-known non-contacting 3-D measurement method. the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this study, digital two-wavelength phase shilling moire is applied to the entertainment fields. recently. as promoting the growth of the VR-Game, display devices which attract public attention such as HMD or Projector are being appeared in order to deliver effectively the absorption sense. this study realized the Auto-calibrating system for arbitrary display surface using digital moire method which satisfied the shape measurement of display surface and the request of FOV(Field of View) output. also when large screen wasn't prepared, this auto-calibrating system was applied to enjoy games or movies at home with a projector and walls

  • PDF