• Title/Summary/Keyword: Graphite plate

Search Result 129, Processing Time 0.023 seconds

Low-Velocity Impact Response of Hybrid Laminated Composite Plate (혼합적층된 복합재료평판의 저속충격응답)

  • Lee, Young-Shin;Kang, Kun-Hee;Park, Oung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.713-722
    • /
    • 1991
  • 본 연구에서는 graphite/epoxy와 glass/epoxy 그리고 graphite/epoxy와 kevl- ar/epoxy의 혼합적층된 복합재료 평판의 저속충격에 대한 응답을 유한요소 모델을 사 용하여 수치해석 한후, 각각의 단일적층판들의 결과와 비교하였으며, 이때의 접촉력 관계식은 Yang과 Sun이 제안한 수정된 접촉법칙을 이용하였다. 또한, 수치해석 결과 에서의 충격자의 속도변화로써 혼합적창판 배열에 따른 에너지 흡수율을 계산하였고, 이를 충격특성이 취약한 graphite/epoxy 단일 적층판의 결과와 비교 고찰하였다.

Effect of Surface-Modified Carbon Fiber on the Mechanical Properties of Carbon/Epoxy Composite for Bipolar Plate of PEMFC (표면처리 탄소섬유가 PEMFC용 탄소/에폭시 복합재료 분리판의 기계적 강도에 미치는 영향)

  • LEE, HONGKI;HAN, KYEONGSIK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.1
    • /
    • pp.49-56
    • /
    • 2020
  • Epoxy/carbon composite was used to prepare a bipolar plate for polymer electrolyte membrane fuel cell (PEMFC). Phenol novolac-type epoxy and diglycidyl ether of bisphenol A (DGEBA)-type epoxy mixture was used as a matrix and graphite powder, carbon fiber (CF) and graphite fiber (GF) were used as carbon materials. In order to improve the mechanical properties of the bipolar plate, surface-modified CF was incorporated into the epoxy/carbon composite. To determine the cure temperature of the epoxy mixture, differential scanning calorimetry (DSC) analysis was performed and the data were introduced to Kissinger equation in order to get reaction activation energy and pre-exponential factor. Tensile and flexural strength was obtained by using universal testing machine (UTM). The surface morphology of the fractured specimen and the interfacial morphology between epoxy matrix and CF or GF were observed by a scanning electron microscopy (SEM).

Comparative Study on Low-velocity Impact Behavior of Graphite/Epoxy Composite laminate and Steel Plate (탄소/에폭시 복합재 적층판과 강판의 저속충격 거동에 관한 비교 연구)

  • Kong, Chang-Duk;Kim, Yeong-Gwang;Lee, Seung-Hyeon
    • Composites Research
    • /
    • v.20 no.5
    • /
    • pp.1-6
    • /
    • 2007
  • This study was performed to make a comparison on low-velocity impact behavior between graphite/epoxy composite laminate and steel plate. In order to validate the proposed scheme fur the impact behavior of the plate, the Karas's impact model was used. The impact models for this comparative study are the graphite/epoxy composite plate having $[0/90/45/-45/-45/45/90/0]_{8S}$ laminate sequence and the steel plate with a steel ball impactor. The low-velocity impact behaviors for two types of plates were comparatively investigated and performed by considering different impactor velocities and weights respectively. In this investigation, it was found that the composite laminate has impact energy absorption effect due to more flexible behavior than the steel plate, and also it has better characteristics on impact damage and weight.

Preparation of Porous Graphite by Using Template of Co- and Ni-Magadiite (Co, Ni 마가다이트 주형을 이용한 다공성 흑연의 합성)

  • Jeong Soon-Yong
    • Journal of Powder Materials
    • /
    • v.12 no.2 s.49
    • /
    • pp.151-158
    • /
    • 2005
  • Porous graphite was synthesized by removal of template in HF after pyrolysis of pyrolyzed fuel oil (PFO) at $900^{\circ}C$ using the template of Co or Ni intercalated magadiite. Porous graphite had a plate structure like template, and d-spacing value of about 0.7 nm. The extent of crystallization of porous graphite was dependent on the contents of Co or Ni intercalated in interlayer. It can be explained that the metal such as Co and Ni acts as a promotion catalyst for graphite formation. Porous graphite shows the surface area of $328\sim477 m^2/g$.

Evaluation and Fabrication of Composite Bipolar Plate to Develop a Light Weight Direct Methanol Fuel Cell Stack for Small-scale UAV Application (I) (무인항공기용 경량화 직접메탄올연료전지 스택 개발을 위한 복합소재 분리판 제작 및 성능 평가 (I))

  • Kang, Kyung-Mun;Park, Sung-Hyun;Kim, Jin-Soo;Ji, Hyun-Jin;Ju, Hyun-Chul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.2
    • /
    • pp.134-142
    • /
    • 2012
  • A bipolar plate is a major component of a fuel cell stack, which occupies 50~60% of the total weight and over 50% of the total cost of a typical fuel cell stack. In this study, a composite bipolar plate is designed and fabricated to develop a compact and light-weight direct methanol fuel cell (DMFC) stack for a small-scale Unmanned Aerial Vehicle (UAV) application. The composite bipolar plates for DMFCs are prepared by a compression molding method using resole type phenol resin as a binder and natural graphite and carbon black as a conductor filler and tested in terms of electrical conductivity, mechanical strength and hydrogen permeability. The flexural strength of 63 MPa and the in-plane electrical conductivities of 191 S $cm^{-1}$ are achieved under the optimum bipolar plate composition of phenol : 18%; natural graphite : 82%; carbon black : 3%, indicating that the composite bipolar plates exhibit sufficient mechanical strength, electrical conductivity and hydrogen permeability to be applied in a DMFC stack. A DMFC with the composite bipolar plate is tested and shows a similar cell performance with a conventional DMFC with graphite-based bipolar plate.

Effects of binder type and heat treatment temperature on physical properties of a carbon composite bipolar plate for PEMFCs

  • Kang, Dong-Su;Roh, Jea-Seung
    • Carbon letters
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2013
  • This study investigated a developed process for producing a composite bipolar plate having excellent conductivity by using coal tar pitch and phenol resin as binders. We used a pressing method to prepare a compact of graphite powder mixed with binders. Resistivity of the impregnated compact was observed as heat treatment temperature was increased. It was observed that pore sizes of the GCTP samples increased as the heat treatment temperature increased. There was not a great difference between the flexural strengths of GCTP-IM and CPR-IM as the heat treatment temperature was increased. The resistivity of GPR700-IM, heat treated at $700^{\circ}C$ using phenolic resin as a binder, was $4829{\mu}{\Omega}{\cdot}cm$ which was best value in this study. In addition, it is expected that with the appropriate selection of carbon powder and further optimization of process we can produce a composite bipolar plate which has excellent properties.

Effect of Carbon Fiber on Electrical and Mechanical Properties of Epoxy/Graphite Bipolar Plate (에폭시/Graphite계 Bipolar Plate의 전기적, 물리적 성질에 미치는 Carbon Fiber의 영향)

  • Choi, Bum-Choul;Lee, J.J.;Lee, Jae-Young;Park, Yunkyeong;Lee, Hong-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.92.1-92.1
    • /
    • 2011
  • 고분자 전해질 연료전지 (PEMFC)의 핵심 부품 중의 하나인 Bipolar Plate (분리판)을 제조하기 위해서 고분자/그라파이트 복합재료를 사용하였다. 고분자 매트릭스로는 경화시 뛰어난 화학적, 기계적 특성을 갖는 에폭시를 채택하였고, 전기 전도성을 부여하기 위해 그라파이트를 도입하였으며, 에폭시 수지의 내충격성을 향상시키기 위해서 Carbon Fiber를 채택하였다. 에폭시 분말과 그라파이트 분말, 그리고 1cm 정도의 길이를 갖는 Carbon Fiber을 믹서에 넣고 균일하게 혼합하였다. 이 혼합물을 이형제 처리된 몰드에 주입하고, Hot Press를 사용하여 가열, 가압 ($150^{\circ}C$, 4 ton/$cm^2$, 2시간)하면서 경화시켰다. 일정 비율로 고정된 에폭시/그라파이트 계에 Carbon Filber의 혼합 비율을 변화시키면서 전기적, 물리적 성질의 변화를 연구하였다.

  • PDF

Advanced Lake Water Treatment with Bipolar Packed Bed Electrode Cell(II) (3차원 전극(Bipolar Packed Bed Electrode)을 이용한 호소수 처리(II))

  • 장철현;박상우;최창수
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.355-360
    • /
    • 2002
  • This study was to analyze the right of wrong of gray-water treatment by applying BPBE electrode cell to the effluence water in the terminal disposal plant of sewage. The results were as follows : The best result was obtained with applied voltage 40V and detention time 6 minutes for the BPBE electrode cell which has the graphite-plate in main electro-de, packing coconut activated carbon. The elimination rate of COD of Al-plate was higher than that of graphite-plate in main electrode. The result of electrolysis for 3 hour in parallel circuit showed the using possibility of gray-water according to each elimination rate : COD 59%, T-N 69 %, T-P 69%. The BPBE electrode cell with the Al-plate in main electrode made the best effect for the elimination of algae in lake water and algae were not occurred in electrolytic water.

Thermal Dissipation Property of Acrylic Composite Films Containing Graphite and Carbon Nanotube (흑연과 탄소나노튜브 함유 아크릴 복합체 박막의 방열 특성)

  • Kim, Junyeong;Kang, Chan Hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.198-205
    • /
    • 2017
  • Thermal dissipation was investigated for poly methyl methacrylate (PMMA) composite films containing graphite and multi wall carbon nanotube(CNT) powders as filler materials. After mixing PMMA with fillers, solvent, and dispersant, the pastes were prepared by passing through a three roll mill for three times. The prepared pastes were coated $15{\sim}40{\mu}m$ thick on a side of 0.4 mm thick aluminium alloy plate and dried for 30 min at $150^{\circ}C$ in an oven. The content of fillers in dried films was varied as 1, 2, and 5 weight % maintaining the ratio of graphite and CNT as 1:1. Raman spectra from three different samples exhibited D, G and 2D peaks, as commonly observed in graphite and multi wall CNT. Among those peaks, D peak was prominent, which manifested the presence of defects in carbon materials. Thermal emissivity values of three samples were measured as 0.916, 0.934, and 0.930 with increasing filler content, which were the highest ever reported for the similar composite films. The thermal conductivities of three films were measured as 0.461, 0.523, and $0.852W/m{\cdot}K$, respectively. After placing bare Al plate and film coated samples over an opening of a polystyrene box maintained for 1 h at $92^{\circ}C$, the temperatures inside and outside of the box were measured. Outside temperatures were lower by $5.4^{\circ}C$ in the case of film coated plates than the bare one, and inside temperatures of the former were lower by $3.6^{\circ}C$ than the latter. It can be interpreted that the PMMA composite film coated Al plates dissipate heat quicker than the bare Al plate.