• Title/Summary/Keyword: Grafting density

Search Result 48, Processing Time 0.025 seconds

A Study on Synthesis and Hydrolysis of the Maleated Polyethylene Wax (무수말레인산으로 그라프트된 폴리에틸렌 왁스의 중합과 가수분해에 대한 연구)

  • Yu, Si-Won;Choi, Joong-So;Na, Jae-Sik
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.393-400
    • /
    • 2013
  • In this study, Polyethylene wax, which was produced in manufacturing process of high density polyethylene was grafted with maleic anhydride (MAH). The influences of reaction parameters on the graft polymerization as well as the effect of hydrolysis of the anhydride functions were investigated. The results show that the grafting degree increased and conversion of maleic anhydride decreased with an increase in MAH monomer content. This means the highest grafting efficiency for the reaction can be met when MAH monomer content is about 15 wt%. DCP (dicumyl peroxide) and DTBP (di-tert-butyl peroxide) have been used as the initiator and the highest yield of grafting was obtained when the initiator content is about 0.5 wt%. However, It can be seen that the gel content values of this polyethylene wax grafted MAH were below 2%. It was also observed that the grafting degree increased with an increase in reaction temperature and the maximum value was reached 2 hours later. Although MAH functions grafted onto polyethylene wax were mainly in the carboxylic acid forms, some anhydride form of MAH appeared in over 5% of grafting degree. As a result of hydrolysis reaction, it was observed that the conversion of anhydride group into carboxylic acid group was reached up to 10%.

Effects of Oxyfluorination on Surface Graft Polymerization of Low Density Polyethylene Film and Its Surface Characteristics (함산소불소화가 저밀도 폴리에틸렌 표면의 그라프트 중합 및 그 표면 특성에 미치는 영향)

  • Yun, Seok-Min;Woo, Sang-Wook;Jeong, Eui-Gyung;Bai, Byong-Chol;Park, In-Jun;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.343-348
    • /
    • 2010
  • The surface of low density polyethylene (LDPE) film was oxyfluorinated under different reaction conditions to introduce hydroperoxide groups and change surface characteristics. Hydroperoxide functional groups created by oxyfluorination were used as active sites for graft polymerization with hydrophobic monomer, acryl amide (AM), and hydrophilic monomer, methyl methacrylate (MMA) to carry out the second modification of the LDPE film surface. The surface properties of the OFPE films and grafted OFPE films were characterized by 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging method, ATR-IR, contact angle measurement and DSC. From the results of DPPH method, the amount of hydroperoxide groups on the oxyfluorinated LDPE film continuously increased as the total pressure in the oxyfluorination and the partial pressure of fluorine gas increased. The water contact angle and surface free energy measurements showed that hydrophilic liquid (water) contact angle on LDPE film surface decreased with hydrophilic AM grafting and hydrophobic liquid (methylene diiodide) contact angle on LDPE film surface decreased with hydrophobic MMA grafting. These were attributed to AM or MMA monomer grafting and the wettability of LDPE filmsurface to hydrophilic and hydrophobic liquids were improved.

Study on the Characteristic of Elastomer Composite Containing Tungsten Powder

  • Chung, Kyungho
    • Elastomers and Composites
    • /
    • v.56 no.1
    • /
    • pp.6-11
    • /
    • 2021
  • In order to develop an ultra-high-density elastomeric material for substitution of steel dynamic dampers, a new curing system and technique for high-loading of the filler were examined in this study. Mechanochemical modification of chloroprene rubber (MAH-g-CR) using an internal mixer was carried out with maleic anhydride (MAH) as a reactive monomer. The optimum amount of MAH was 10 phr and the efficient grafting of MAH on CR could be achieved at a mixing temperature of 100℃. After preparing MAH-g-CR, 50 mol% epoxidized natural rubber (ENR 50) was blended with MAH-g-CR to develop a "self-curable rubber blend system" via reaction between the functional groups of the elastomeric matrices without the curing agent and additives. The content of ENR 50 was fixed at 30 wt.% throughout evaluation of the curing behavior of the MAH-g-CR/ENR blend. Tungsten powder was added to the MAH-g-CR/ENR matrix up to 60 vol.% to obtain ultra-high-density, and the maximum density obtained was 7.57 g/㎤. Stable ts2 (scorch time) and t90 (90% cure time) could be obtained even when tungsten powder was incorporated up to 60 vol.%. In addition, the tensile strength and damping properties of MAH-g-CR/ENR containing 60 vol.% of tungsten were better than those of CR containing 60 vol.% of tungsten.

Quality and Morphology on cortico-cancellous bone in Korean mandibular symphysis area (한국인 하악 유합부에서의 피질골-해면골의 밀도 및 형태)

  • Min, Cheon-Ki;Park, Hyun-Do;Kim, Chang-sung;Jung, Han-Sung;Cho, Kyoo-Sung;Kim, Hee-Jin;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.581-595
    • /
    • 2001
  • In performing implant procedures in the anterior portion of the maxilla, many difficulties exist because of anatomical reasons, such as the proximity of the nasal floor, lateral extension of the incisive canal, and labial concavity. On the other hand, in the posterior region of the maxilla, there is often insufficient recipient bone between the maxillary sinus and alveolar ridge due to alveolar ridge resorption and pneumatization of the maxillary sinus. In order to perform implants in such regions, ridge augmentation procedures such as onlay bone graft, guided bone regeneration, and maxillary sinus grafting are performed. In studies of Caucasians, use of autograft from mandibular symphysis has been reported to be highly successful in maxillary sinus grafting. However, in a clinical study of Koreans, autograft of mandibular symphysis has been reported to have significantly low success rate. It has been hypothesized that this is because of insufficient cancellous bone due to thick cortical bone. In order to test this hypothesis, bone quality and morphology of Koreans can be compared with those of Caucasians. In this study, the bone density and morphology of the cortical bone and cancellous bone in the mandibular symphysis of 35 Korean cadavers were evaluated. The following results were obtained: 1. In terms of bone density, type I, type II, and type III consisted of 1.4%(3/213), 72.3%(154/213), and 26.3%(56/213) of the cross-sectioned specimens, respectively. In general, the bone density tended to change from type II to type III, as cross-sectioned specimens were evaluated from the midline to the canine. Type IV wasn't observed in this study. 2. The distance between the root apex and the lower border of the cancellous bone was 18.34mm-20.59mm. Considering that the bone has to be cut 5mm below the root apex during the procedure, autografts with about 15mm of vertical thickness can be obtained. 3. The thickness of cortical bone on the labial side increased from the root apex to the lower border of the mandible. The average values ranged from 1.43mm to 2.36mm. 4. The labio-lingual thickness of cancellous bone ranged from 3.43mm to 6.51mm. The thickness tended to increase from the apex to the lower border of the mandible and decrease around the lower border of cancellous bone. From the above results, the anatomic factors of the mandibular symphysis (bone density, thickness, quantity and length of the cortical bone and cancellous bone) didn't show any difference from Caucasians, and it cannot be viewed as the cause of failure in autografts in the maxillary sinus for implants.

  • PDF

Effect of Cardiac Rehabilitation Education for Coronary Artery Bypass Grafting Patients during Their Hospitalization (입원 기간 중 관상동맥 우회술 환자를 위한 심장재활 교육의 효과)

  • Choe, Myoung-Ae;Kim, Keum-Soon;Yi, Myung-Sun;ChoiKwon, S-Mi;Lee, Jung-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.10 no.1
    • /
    • pp.69-79
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of cardiac rehabilitation education for CABG patients on anxiety & depression, self-esteem, general health status, health related quality of life, body mass index, serum lipid concentration (high density lipoprotein, low density lipoprotein, total cholesterol), heart rate and blood pressure. The subjects of the study consisted of 36 patients who underwent CABG at A hospital in Seoul, from January 1, 2006 to June 30, 2007. The experimental group (20 patients) received the individual education during the hospitalization. The control group (16 patients) received routine discharge education by ward nurses. Psychological variables, general health status and health related quality of life (QOL) after cardiac rehabilitation education were determined by self-reported questionnaire at 1st week, 3rd week and 6th week after the discharge. Physiological variables were measured in out patient visiting at 4th week after discharge. Score of anxiety & depression and health related QOL in the experimental group showed a significant decrease at 1st week, 3rd week and 6th week after the discharge compared with the control group. Score of self-esteem, general health status and physiological variables in the experimental group showed no significant difference from the control group.

  • PDF

Socket preservation using eggshell-derived nanohydroxyapatite with platelet-rich fibrin as a barrier membrane: a new technique

  • Kattimani, Vivekanand Sabanna;Lingamaneni, Krishna Prasad;Kreedapathi, Girija Easwaradas;Kattappagari, Kiran Kumar
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.332-342
    • /
    • 2019
  • Objectives: Socket grafting is vital to prevent bone resorption after tooth extraction. Several techniques to prevent resorption have been described, and various bone graft substitutes have been developed and used with varying success. We conducted this pilot study to evaluate the performance of nanohydroxyapatite (nHA) derived from chicken eggshells in socket preservation. Materials and Methods: This was a prospective, single center, outcome assessor-blinded evaluation of 23 sockets (11 patients) grafted with nHA and covered with platelet-rich fibrin (PRF) membrane as a barrier. Bone width and radiographic bone density were measured using digital radiographs at 1, 12, and 24 weeks post-procedure. Postoperative histomorphometric and micro-computed tomography (CT) evaluation were performed. The study protocol was approved by the Institutional Ethics Committee. Results: All patients had uneventful wound healing without graft material displacement or leaching despite partial exposure of the grafted socket. Tissue re-epithelialized with thick gingival biotype (>3 mm). Width of the bone was maintained and radiographic density increased significantly with a trabecular pattern (73.91% of sockets) within 12 weeks. Histomorphometric analysis showed 56.52% Grade 3 bone formation and micro-CT analysis revealed newly formed bone with interconnecting trabeculae. Conclusion: Use of a PRF membrane with nHA resulted in good bone regeneration in sockets. Use of a PRF membrane prevents periosteal-releasing incisions for primary closure, thereby facilitating the preservation of keratinized mucosa and gingival architecture. This technique, which uses eggshell-derived nHA and PRF membrane from the patient's own blood, is innovative and is free of disease transfer risks. nHA is a promising economic bone graft substitute for bone regeneration and reconstruction because of the abundant availability of eggshell waste as a raw material.

MULTIPLE PEGYLATION OF PANCREATIC ISLETS FOR IMMUNOPROTECTION IN ISLET TRANSPLANTATION

  • Yang, Kyung-Wook;Lee, Moon-Kyu;Byun, Young-Ro
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.695-698
    • /
    • 2000
  • We studied the viability and function of islet with monomethoxy polyethylene glycol (mPEG) grafted onto its membrane. Islets were isolated from rat and were repeatedly reacted with activated mPEG (mw 5000) in order to increase grafting density. The density of grafted PEG on the islet membrane was confirmed by Fluorescein-PEG-NHS. An assessment of islet viability using AO / PI staining method showed that multiple PEGylation did not reduce islet viability. The function of PEG grafted islets was evaluated by measuring released insulin from islets. Insulin secreted from the PEGylated islets for 1 h did not show any significant difference compared to control (non-PEGylated) islets. In addition, PEGylated islets responded in the same pattern as control islets in the perifusion test.

  • PDF

Effect of Bone Marrow Aspirate with Autogenous Bone graft for Alveolar Cleft in a new Rabbit Model (가토의 치조열 모델에서 골수 흡인물이 자가뼈 이식술에 미치는 효과)

  • Bae, Sung Gun;Chung, Ho Yun;Lee, Sang Yun;Cho, Byoung Chae;Yang, Jung Dug;Park, Mee Young
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.531-537
    • /
    • 2009
  • Purpose: Alveolar bone grafting has become an essential process in the treatmemt of alveolar cleft patient for stabilization of the maxillary arch, elimination of oronasal fistula, the reconstruction of the soft tissue nasal base support, and creation of bony support for tooth eruption for implant. The use of Autologous iliac cancellous bone is preferable because of the adequate quantity and high osteoinductive potential. However, even with iliac bone, insufficient osteoregeneration and absorption occur due to several factors such as the patient's age, cleft width, functional stress, and others. In order to increase osteoregeneration where the iliac bone is placed, the present study is associated with bone marrow aspirate (BMA). The experimental study evaluated the efficacy of osteoregeneration in normal cleft rabbits when alveolar bone grafting was performed with autologous iliac corticocancellous bone. Methods: Twenty - four New Zealand White rabbits were divided randomly into 2 groups (BMA, control). All animals underwent harvesting of corticocancellous bone graft from the right posterior iliac crest via standard surgical technique. $1m{\ell}$ of BMA were obtained by scraping the needle and aspirate with $10m{\ell}$ syringe from the contralateral iliac bone wall. The muco - periosteal flap on the palate was elevated. A mixture of Equal bone's volumes with BMA and saline as its control was inserted into the cleft. Animals were sacrificed at 2, 4, and 8 weeks and maxilla was harvested for dental peri - apical X-ray, bone matrix density (BMD),and histologic analysis. Result: BMD of regenerated bone to the cleft in the rabbits was higher than that of the control rabbits. X-ray, histologic analysis showed that increased osteoregeneration and low absorption rate were observed in the BMA group. Conclusion: Our experimental study showed BMA enhanced the osteoregeneration and survival rate of alveolar bone grafting. BMA is easy to extract & cost - time effective. So it can be an effective enhancers for bone grafting mixtures.

Surface Modification of Matrix and filler for Ultra High Density Elastomeric Material (초 고비중 탄성체 개발을 위한 매트릭스 탄성체 표면개질 및 충전제 제어기술 기초연구)

  • Chung, K.;Lee, D.;Yang, K.;Lee, W.;Hong, C.
    • Elastomers and Composites
    • /
    • v.40 no.2
    • /
    • pp.93-103
    • /
    • 2005
  • In this study, surface treatment of the elastomeric matrix was investigated to develop a substituting material for steel dynamic damper of automobile. The key technology is to get ultra high density elastomeric compound in order to substitute steel dynamic damper. The optimum matrix material(chloroprene rubber) and filler(metal powder) were selected for this. The several properties of elastomeric compound were examined. According to the results, the $t_{s2}$ of filled elastomeric compound was decreased with increasing the filler loading whereas the $t_{90}$ was increased. Also, tensile strength and rebound resilience were decreased with filler loading. To solve the problem of high filler loading, the photo grafting technique was employed on elastomeric matrix. The degree of grafting was determined by FTIR-ATR. Also, the filler surface was modified by chemical etching and the surface morphology was examine by SEM. After chemical treatment of filler, the particle size analyzer was used to examined the particle size, size distribution, and morphology of the modified filler.

Low density polyethylene/nylon-6 reactive blend using corotating twin screw extruder (동방향 이축압출기를 이용한 저밀도폴리에틸렌/나일론-6 반응블렌드)

  • Ryu, Sung-Hun;Chung, Young-Bae
    • Elastomers and Composites
    • /
    • v.40 no.3
    • /
    • pp.159-165
    • /
    • 2005
  • Reactive monomer, glycidyl methacrylate (GMA), was grafted onto low density polyethylene (LDPE) using peroxide and then reactive blend with nylon-6 was rallied out by corotating twin screw extruder. Grafting of GMA was identified using FT-IR. Graft ratio or GMA increased with reaction temperature, peroxide concentration and styrene comonomer concentration. It is observed that tensile elongation and tensile strength or LDPE-g-GMA/nylon-6 blend were higher than those of LDPE/nylon-6 blend. Morphology of blend was analyzed using SEM.