• 제목/요약/키워드: Gradient of Electrode

검색결과 53건 처리시간 0.028초

구조체 접지전극의 유형에 따른 전위경도 특성 (Characteristics of Potential Gradient for the Type of Structure Grounding Electrode)

  • 길형준;최충석;김향곤;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.371-377
    • /
    • 2005
  • This paper Presents the Potential gradient characteristics of structure grounding electrode when a test current flows through grounding electrode. In order to analyze the potential gradient of ground surface on structure grounding electrode, the reduced scale model has been used. The potential gradient has been measured and analyzed for types of structure using the hemispherical grounding simulation system in real time. The structures were designed through reducing real buildings and fabricated with four types on a scale of one-one hundred sixty. The supporter was made to put up with weight of structure and could move into vertical, horizontal, rotary direction. When a test current flowed through structure grounding electrodes, ground potential rise was the lowest value at electric cage type(type B). According to resistivity and absorption percentage In concrete attached to structure, the potential distribution of ground surface appeared differently.

Fundamentals of Stress-Induced Diffusion: Theoretical Approach to Hydrogen Transport through Self-Stressed Electrode

  • Lee, Sung-Jai;Pyun, Su-Il
    • 전기화학회지
    • /
    • 제8권1호
    • /
    • pp.47-54
    • /
    • 2005
  • This article covers the fundamentals of stress-induced diffusion, focusing on the theoretical model for hydrogen transport through self-stressed electrode. First, the relationship between hydrogen diffusion and macroscopic deformation of the electrode specimen was briefly introduced, and then it was classified into the diffusion-elastic and elasto-diffusive phenomena. Next, the transport equation for the flux of hydrogen caused simultaneously by both the concentration gradient and the stress gradient was theoretically derived. Finally, stress-induced diffusion was discussed on the basis of the numerical solutions to the derived transport equation under the permeable and impermeable boundary conditions.

Electrochemical stability of La0.6Sr0.4Co0.2Fe0.8O3-δ as a cathode for SOFC

  • Oh, Mi-Young;Jeong, Yong-Hoon;Oh, Se-Woong
    • 한국표면공학회지
    • /
    • 제49권6호
    • /
    • pp.498-506
    • /
    • 2016
  • Electrochemical measurement using a LSCF6428 electrode was performed to estimate the oxygen potential gradient in the electrode layer and a long time stability test was performed by applied potential to learn the overpotential effect on the LSCF6428 electrode. By fitting the observed impedance spectra, it was obtained that the amount of faradic current decreased with distance from cathode/electrolyte interface. Oxygen potential gradient was estimated to occur within 1 um region from the cathode/electrolyte interface at an oxygen partial pressure of 10-1 bar. The segregation of cation rich phases in the LSCF6428 electrode suggests that kinetic decomposition took place. However, impedance response after applying the potential showed no changes in the electrode compared with before applying potential. The obtained results suggest that segregation of a secondary phase in a LSCF6428 cathode is not related to performance degradation for solid oxide fuel cells (SOFCs).

드레인-소스 전극 간극의 변화에 따른 Gas Sensor의 열에너지 확산 해석 (Heat Energy Diffusion Analysis in the Gas Sensor Body with the Variation of Drain-Source Electrode Distance)

  • 장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.589-595
    • /
    • 2017
  • MOS-FET structured gas sensors were manufactured using MWCNTs for application as NOx gas sensors. As the gas sensors need to be heated to facilitate desorption of the gas molecules, heat dispersion plays a key role in boosting the degree of uniformity of molecular desorption. We report the desorption of gas molecules from the sensor at $150^{\circ}C$ for different sensor electrode gaps (30, 60, and $90{\mu}m$). The COMSOL analysis program was used to verify the process of heat dispersion. For heat analysis, structure of FET gas sensor modeling was proceeded. In addition, a property value of the material was used for two-dimensional modeling. To ascertain the degree of heat dispersion by FEM, the governing equations were presented as partial differential equations. The heat analysis revealed that although a large electrode gap is advantageous for effective gas adsorption, consideration of the heat dispersion gradient indicated that the optimal electrode gap for the sensor is $60{\mu}m$.

유한요소법에 의한 ZnO 바리스터 동작 시 발생되는 열폭주 현상 해석 (Analysis of Thermal Runaway Phenomenon Caused by ZnO Varistor Operation Using Finite Element Method)

  • 장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.372-376
    • /
    • 2022
  • Since the ZnO varistor is a semiconductor device, the internal thermal distribution during the varistor operation is recognized as an important factor in the performance and deterioration of the varistor. For an optimal varistor structure design, the thermal runaway phenomenon during the varistor operation was interpreted using the Comsol 5.2 analysis program by a finite element analysis. The maximum temperature of the center measured in the cross section of the ZnO varistor was confirmed to increase as the temperature moved from the lower electrode to the center towards the upper electrode up to 572.6 K. The electrodes are thinned so that the influence of the Schottky barrier is not great. The heat gradient balance is determined to be improved when the electrode of the hybrid form is introduced. The thickness, density, pore distribution, impurity uniformity, and particle size of the ZnO varistor are required, and it is determined that the pyrolysis gradient will be improved regardless of the electrode thickness. When these results are applied to design the ZnO varistor, the optimal structure of the ZnO varistor can be obtained.

Efficient cell design and fabrication of concentration-gradient composite electrodes for high-power and high-energy-density all-solid-state batteries

  • Kim, Ju Young;Kim, Jumi;Kang, Seok Hun;Shin, Dong Ok;Lee, Myeong Ju;Oh, Jimin;Lee, Young-Gi;Kim, Kwang Man
    • ETRI Journal
    • /
    • 제42권1호
    • /
    • pp.129-137
    • /
    • 2020
  • All-solid-state batteries are promising energy storage devices in which high-energy-density and superior safety can be obtained by efficient cell design and the use of nonflammable solid electrolytes, respectively. This paper presents a systematic study of experimental factors that affect the electrochemical performance of all-solid-state batteries. The morphological changes in composite electrodes fabricated using different mixing speeds are carefully observed, and the corresponding electrochemical performances are evaluated in symmetric cell and half-cell configurations. We also investigate the effect of the composite electrode thickness at different charge/discharge rates for the realization of all-solid-state batteries with high-energy-density. The results of this investigation confirm a consistent relationship between the cell capacity and the ionic resistance within the composite electrodes. Finally, a concentration-gradient composite electrode design is presented for enhanced power density in thick composite electrodes; it provides a promising route to improving the cell performance simply by composite electrode design.

Bonding Strength of Conductive Inner-Electrode Layers in Piezoelectric Multilayer Ceramics

  • Wang, Yiping;Yang, Ying;Zheng, Bingjin;Chen, Jing;Yao, Jinyi;Sheng, Yun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권4호
    • /
    • pp.181-184
    • /
    • 2017
  • Multilayer ceramics in which piezoelectric layers of $0.90Pb(Zr_{0.48}Ti_{0.52})O_3-0.05Pb(Mn_{1/3}Sb_{2/3})O_3-0.05Pb(Zn_{1/3}Nb_{2/3})O_3$ (0.90PZT-0.05PMS-0.05PZN) stack alternately with silver electrode layers were prepared by an advanced low-temperature co-fired ceramic (LTCC) method. The electrical properties and bonding strength of the multilayers were associated with the interface morphologies between the piezoelectric and silver-electrode layers. Usually, the inner silver electrodes are fabricated by sintering silver paste in multi-layer stacks. To improve the interface bonding strength, piezoelectric powders of 0.90PZT-0.05PMS-0.05PZN with an average particle size of $23{\mu}m$ were added to silver paste to form a gradient interface. SEM observation indicated clear interfaces in multilayer ceramics without powder addition. With the increase of piezoelectric powder addition in the silver paste, gradient interfaces were successfully obtained. The multilayer ceramics with gradient interfaces present greater bonding strength as well as excellent piezoelectric properties for 30~40 wt% of added powder. On the other hand, over addition greatly increased the resistance of the inner silver electrodes, leading to a piezoelectric behavior like that of bulk ceramics in multilayers.

Trace Mercury Determination by Differential Pulse Anodic Stripping Voltammetry Using Polythiophene-Quinoline/Glassy Carbon Modified Electrode

  • Yoo, Kwang-Sik;Woo, Sang-Beom;Jyoung, Jy-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.27-31
    • /
    • 2003
  • A Polythiophene-quinoline/glassy carbon (PTQ/GC) modified electrode was developed for the determination of trace mercury in industrial waste water, natural water, soil, and other media. The electrode was prepared by the cyclic voltammetric polymerization of thiophene and quinoline on glassy carbon (GC) electrode by the potential application from -0.6 V to +2.0 V (50 mV/sec) in a solution of 0.1 M thiophene, quinoline and tetrabutyl ammonium perchlorate (TBAP) in acetonitrile. Optimum thickness of the polymer membrane on the GC electrode was obtained with 20 repeated potential cyclings. The redox behavior of Cu(Ⅱ) and Hg(Ⅱ) were almost identical on this electrode. The addition of 4-(2-pyridylazo)resorcinol (PAR) to the solution containing Cu(Ⅱ) and Hg(Ⅱ) allowed the separation of the components due to the formation of the Cu(Ⅱ)-PAR complex reduced at -0.8V, which was different from the Hg(Ⅱ) reduced at -0.5 V on a saturated calomel electrode (SCE). The calibration graph of Hg(Ⅱ) shows good linear relationship with the correlation factor of 0.9995 and the concentration gradient of 0.33 ㎂/㎠/ppb down to 0.4 ppb Hg. The method developed was successfully applied to the determination of mercury in samples such as river, waste water, and sea water.

유한요소법에 의한 적층형 세라믹 히터의 전극 패턴 최적화 (Optimization of Electrode Pattern for Multilayer Ceramic Heater by Finite Element Method)

  • 한윤수;김시연;여동훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.776-781
    • /
    • 2017
  • In this study, we investigated the effect of electrode pattern design on the thermal shock resistance and temperature uniformity of a ceramic heater. A cordierite substrate with a low thermal expansion coefficient was fabricated by tape casting, and a tungsten electrode was printed and used as a heating element. The temperature distribution of the ceramic heater was calculated by a finite-element method (FEM) by considering various electrode patterns, and the tensile stress distribution due to the thermal stress was calculated. In the electrode pattern with a single-line width, the central part of the ceramic heater was heated to the maximum temperature, and the position of the ceramic heater having a double-line width was changed to the maximum temperature, depending on the position of the minimum line width pattern. The highest tensile stress was found along the edges of the ceramic heater. The temperature gradient at the edge determined the tensile stress intensity. The smallest tensile stress was observed for electrode pattern D, which was expected to be advantageous in resisting thermal shock failures in ceramic heaters.

Determination of the voltage distribution in the external electrode fluorescent lamps for the backlight unit of large-size LCD

  • Choi, Jae-Young;Kim, Young-Youb;Ko, Jae-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1374-1377
    • /
    • 2006
  • The voltage distribution of an external electrode fluorescent lamp(EEFL) having a gas pressure of 50 torr and a gas composition of Ne:Ar with a ratio of 90:10 has been estimated by varying the distance between the two external electrodes and monitoring the change of the lamp voltage. The estimated voltage gradient, which represents the electric field in the positive column of the EEFL, was very sensitive to the electrode area of EEFL and was in the range of $13\;{\sim}\;27\;V/cm$ at the electrode length of $15\;{\sim}\;31\;mm$. Changing the lamp current in the range $3\;{\sim}\;5\;mA$ did not make noticeable difference in the electric field of the positive column. Theses results may serve as basic data for the optimization of electric and optic characteristics of EEFL.

  • PDF