• Title/Summary/Keyword: Gradient array

Search Result 137, Processing Time 0.027 seconds

IMAGING THE CIRCUMSTELLAR ENVELOPES AROUND EVOLVED STARS WITH THE SMA

  • HIRANO NAOMI;CHIU PO-JIAN;MULLER SEBASTIEN;TRUNG DINH-V
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.219-222
    • /
    • 2005
  • We present the high-resolution (2"-4") images of the molecular envelopes surrounding the evolved stars, V Hya, VY CMa, and ${\pi}^1$ Gru observed with the Submillimeter Array. The CO J=2-1 and 3-2 images of the carbon star V Hya show that the circumstellar structure of this star consists of three kinematic components; there is a flattened disk-like envelope that is expanding with a velocity of ${\~}16 km\;s^{-1}$, the second component is the medium-velocity wind having a deprojected velocity of 40-120 km $s^{-l}$ moving along the disk plane, and the third one is the bipolar molecular jet having an extreme velocity of 70-185 km $s^{-l}$. The axis of this high velocity jet is perpendicular to the plane of the disk-like envelope. We found that the circumstellar structure of the S-star ${\pi}^1$ Gru traced by the CO J =2-1 resembles that of V Hya quite closely; the star is surrounded by the expanding disk-like envelope and is driving the medium-velocity wind along the disk plane. We also obtained the excellent images of VY CMa with the CO and $^{13}CO$ J=2-1 and $SO\;6_5-5_4$ lines. The maps of three molecular lines show that the envelope has a significant velocity gradient in the east-west direction, suggesting that the envelope surrounding VY CMa is also flattened and expanding along its radial direction. The high-resolution images obtained with the SMA show that some AGB stars are associated with the asymmetric mass loss including the equatorial wind and bipolar jet.

A Study for Analytical Method of Sudan Colorants in Foods (식품 중 수단색소의 분석법에 관한 연구)

  • 김희연;윤혜정;최장덕;최우정;박선영;이경주;김지혜
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.3
    • /
    • pp.549-552
    • /
    • 2004
  • A simple, efficient and accurate method was developed for the simultaneous determination of non-permitted oil soluble colorants (sudan I, II, III and IV) in foods. The identification has been carried out for sudan colorants by TLC as well as HPLC with photodiode array (PDA) detection. Separation of sudan colorants was achieved within 20 min by a gradient elution with water and acetonitrile as eluents. Sudan colorants showed good linear relationships in the range of 0.1 ~ 100 $\mu\textrm{g}$/mL. The correlation coefficients of the calibration curve for sudan colorants exceeded 0.999. The detection limits (signal-to-noise ratio 3 : 1) for sudan I, II, III and IV were 0.01, 0.01, 0.02 and 0.02 $\mu\textrm{g}$/mL, respectively. This method has been successfully applied to the analysis of red pepper powder, Kimchi and Kakdugi, and the average recoveries for real samples ranged from 83.02% to 104.3%.

Simultaneous Determination of Dictamine, Obacunone and Fraxinellone in Dictamnus dasycarpus cortex by HPLC-DAD (HPLC-DAD를 이용한 백선피의 Dictamine, Obacunone, Fraxinellone의 동시분석법 확립)

  • Song, Ji-Yeon;Lee, Min-A;Yoon, Jeong-Seon;Kim, Dea-Hyun;Kim, Seung-Hyun;Kim, Young-Choong;Sung, Sang-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.323-327
    • /
    • 2010
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of dictamine, obacunone and fraxinellone was established for the quality control of traditional herb Dictamnus dasycarpus cortex. Separation and quantification were successfully achieved with a Shiseido C18 column ($5\;{\mu}m$, 4.6 mm I.D. ${\times}$ 250 mm) by gradient elution of a mixture of methanol and water at a flow rate of 1.0 ml/min. The diode-array UV/Vis detector (DAD) was used for the detection and the wavelength for quantification was set at 236 nm. The presence of dictamine, obacunone and fraxinellone in this extract was ascertained by retention time, spiking with each authentic standard and UV spectrum. All three compounds showed good linearity ($r^2$ > 0.999) in relatively wide concentration ranges. The R.S.D. recovery of each compound was 101.0~103.7% with R.S.D. values less than 1.0%. This method was successfully applied to the determination of contents of dictamine, obacunone and fraxitnellone in three commercial products of D. dasycarpus cortex. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial products.

Simultaneous Determination of Six Bioactive Components in Guibi-tang by HPLC-DAD (HPLC-DAD를 이용한 귀비탕 중 6종 생리활성 물질의 동시분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2010
  • Guibi-tang, a traditional herbal medicine, is used for anti-oxidant, anti-osteoporosis, hemostasis and gastroprotection. To develop an analysis method of simultaneous determination of six compounds, swertisin, decursinol, glycyrrhizin, 6-gingerol, costunolide and decursin in Guibi-tang, a high performance liquid chromatography was used with diode array detector. Six bioactive components were separated on a SHISEIDO $C_{18}$ column ($5\;{\mu}m$, 4.6 mm I.D.${\times}$250 mm) with column temperature $30^{\circ}C$. The gradient elution was composed of water with 0.1% trifluoroacetic acid (TFA) and acetonitrile. UV wavelength was set at 230 nm, 254 nm and 330 nm, respectively. Calibration curve showed good linear regression ($R^2$ > 0.9999). The limits of detection (LOD) and the limits of quantification (LOQ) ranged in 0.03 - 0.23 ${\mu}g/ml$ and 0.08 - $0.70\;{\mu}g/ml$, respectively. The RSD values of intra- and inter-day test were in the range of 0.03 ~ 0.96% and 0.01 ~ 1.46%, respectively. The evaluated results of accuracy test were varied from 92.28% ~ 105.14% with RSD < 1.60%. In conclusion, this developed simultaneous determination method was accuracy and sensitive to the quality evaluation of Guibi-tang.

Simultaneous Determination of Baicalin and Glycyrrhizin in Eul-Ja-Tang by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Park, Jung-Hyun;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-JIn;Kim, Young-Choong;Sung, Sang-Hyun
    • Natural Product Sciences
    • /
    • v.14 no.3
    • /
    • pp.147-151
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, baicalin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Eul-Ja-Tang (EJT). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/VIS detector (DAD) was used for the detection and the wavelength for quantification was set at 250 nm. The presence of baicalin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. Both baicalin and glycyrrhizin showed good linearity ($r^2$ > 0.999) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 5% and the limits of detection (LOD) were about 30 ng. The mean recovery of each compound was 99.5 - 101.2% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of baicalin and glycyrrhizin in three commercial products of EJT, which resulted in the difference in the contents of these compounds. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial EJT products.

Simultaneous Determination of Seven Compounds by HPLC-PDA and Cytotoxicity of Samchulkunbi-tang (삼출건비탕의 HPLC-PDA 동시 분석법 설정 및 세포독성)

  • Seo, Chang-Seob;Lee, Mee-Young;Kim, Jung-Hoon;Lee, Jin-Ah;Shin, Hyeun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.25 no.3
    • /
    • pp.65-71
    • /
    • 2010
  • Objectives:To develop and validate HPLC-PDA methods for simultaneous determination of seven constituents in Samchulkunbi-tang (SKT). Additionally, we investigated the cytotoxicity against BEAS-2B cell line and splenocytes of SKT. Methods:Reverse-phase chromatography using a Gemini $C_{18}$ column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230, 254 and 280 nm, were used for quantification of the three marker components of SKT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. The cytotoxicity of SKT were measured by the CCK-8 assay method. Results:Calibration curves were acquired with $r^2$>0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 6.0%. The recovery rate of each compound was in the range of 86.89-109.78%, with an RSD less than 4.0%. The contents of seven compounds in SKT were 1.39-6.84 mg/g. SKT had no cytotoxicity effect at 50-200 ${\mu}g$/mL concentrations. Conclusions:The established method will be helpful to improve quality control and in vitro efficacy study of SKT.

Simultaneous Quantification of Three Marker Compounds in Samultang by HPLC/DAD (HPLC-DAD를 이용한 사물탕 중 3종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Ma, Jin-Yeul;Lee, Jae-Hoon;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.4
    • /
    • pp.298-302
    • /
    • 2009
  • Samultang is one of traditional medicine composed of Paeonia lactiflora, Angelica gigas, Rehmannia glutinosa and Cnidium officinale. To develop simultaneous determination of paeoniflorin, decursin and 5-HMF in Samultang, a high performance liquid chromatography with diode array detector was used. To separate three marker components, Dionex $C_{18}$ column (5 ${\mu}m$, 120 ${\AA}$, 4.6 mm${\times}$150 mm) was used with a gradient elution system of water and methanol. UV wavelength of detector set at 230 nm and 280 nm. This method was validated by linearity, precision test and recovery test. Calibration curves of three standard components were showed good linear regression ($R^2$>0.9973). LOD and LOQ ranged from 0.08 ${\mu}g$/ml to 0.38 ${\mu}g$/ml and 0.25 ${\mu}g$/ml to 1.16 ${\mu}g$/ml, respectively. The relative standard deviations (RSDs) of data of the inter-day and intra-day experiments were less than 0.54% and 0.89%, respectively. The measured results of recovery test were varied from 93.36 to 107.79 with RSD values 0.01~1.45%. The established method was applied for separation of bio-conversion Samultang sample and compared with control sample.

Simultaneous Determination of 11 Marker Compounds in Gumiganghwal-tang by HPLC-DAD and LC-MS

  • Weon, Jin Bae;Jung, Youn Sik;Ryu, Gahee;Yang, Woo Seung;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.22 no.4
    • /
    • pp.238-245
    • /
    • 2016
  • Gumiganghwal-tang has been used for the treatment of common cold for a long-time. We developed an accurate and sensitive high performance liquid chromatography-diode array detection (HPLC-DAD) and electrospray ionization mass spectrometry method for the simultaneous determination of ferulic acid, baicalin, bergapten, methyl eugenol, glycyrrhizin, oxypeucedanin, wogonin, nodakenin, atractylenolide III, imperatorin, and atractylenolide I in Gumiganghwal-tang samples. The analytes were separated on a Shiseido C18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}250mm$) with gradient elution with acetonitrile and 0.1% trifluoroacetic acid. Eleven compounds were quantitatively determined by HPLC-DAD and identified by LC-MS data. We also validated this method. The calibration curves of all the compounds showed good linear regression. The limits of detection and the limits of quantification ranged from 0.04 to 0.63 and from 0.12 to $1.92{\mu}g/mL$, respectively. The relative standard deviation values of intra- and inter-days of this method represented less than 2.9%. The recoveries were found to be in the range of 90.06 - 107.66%. The developed method has been successfully applied to the analysis of Gumiganghwaltang samples. The established HPLC method could be used to quality control of Gumiganghwal-tang.

Simultaneous Determination of Paeoniflorin and Glycyrrhizin in Sayuk-san by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Jeon, Min-Ji;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-Jin;Sung, Sang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, paeoniflorin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Sayuk-san (SYS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}150mm$) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of paeoniflorin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. All two compounds showed good linearity ($r^2$>0.996) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.3% and the limits of detection (LOD) were less than 55.7 ng. The mean recovery of each compound was $102.3{\sim}111.1%$ with R.S.D. values less than 4.6%. This method was successfully applied to the determination of contents of paeoniflorin and glycyrrhizin in three commercial products of SYS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial SYS products.

Simultaneous Determination of Liquiritin, Nodakenin, Hesperidin and Glycyrrhizin in Bojungikgi-tang Using HPLC-PDA (HPLC-PDA를 이용한 보중익기탕 중 Liquiritin, Nodakenin, Hesperidin 및 Glycyrrhizin의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.57 no.3
    • /
    • pp.187-193
    • /
    • 2013
  • Bojungikgi-tang has been widely used for enhancement of physical fitness in Korea. The convenient, simple, and accurate high-performance liquid chromatography (HPLC) method was established for simultaneous determination of four marker compounds, liquiritin, nodakenin, hesperidin, and glycyrrhizin in Bojungikgi-tang (Buzhongyiqi-tang in Chinese, Hochuekkito in Japanese), a traditional Korean herbal prescription. The column for optimizing HPLC separation was used a Gemini $C_{18}$ column at column oven temperature of $40^{\circ}C$ with 1.0% (v/v) aqueous acetic acid (A) and 1.0% (v/v) acetic acid in acetonitirle (B) by gradient flow. The flow rate was 1.0 ml/min and the detector was a photodiode array (PDA) set at 254 nm, 280 nm, and 335 nm. Calibration curves of four components were acquired with $r^2$ values ${\geq}0.9999$. The recoveries were found to range 92.11~105.68% with relative standard deviations (RSDs, %) value less than 2.50%. The RSD values of intraand inter-day precision were 0.07~2.50% and 0.16~1.99%, respectively. The contents of liquiritin, nodakenin, hesperidin and glycyrrhizin in Bojungikgi-tang were 3.85~3.92 mg/g, 2.27~2.32 mg/g, 4.14~4.19 mg/g, and 3.39~3.45 mg/g, respectively. The established simultaneous analysis method will be effective for quality control of Bojungikgi-tang.