• 제목/요약/키워드: Gradient Echo

검색결과 175건 처리시간 0.024초

Sizes and Structures of Micelles of Cationic Octadecyl Trimethyl Ammonium Chloride and Anionic Ammonium Dodecyl Sulfate Surfactants in Aqueous Solutions

  • Kim, Hong-Un;Lim, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권3호
    • /
    • pp.382-388
    • /
    • 2004
  • The sizes and structures of micelles formed in aqueous solutions of cationic octadecyl trimethyl ammonium chloride (OTAC) and anionic ammonium dodecyl sulfate (ADS) surfactants were investigated using smallangle neutron scattering (SANS), self-diffusion coefficients by pulsed-gradient spin-echo (PGSE) NMR, and dynamic light scattering (DLS) methods. SANS and DLS data indicate that their structures are spherical at concentrations as high as 300 mM. As the total surfactant concentration increases, the peaks of SANS spectra shift to higher scattering vector and become sharper, indicating that the intermicellar distance decreases and its distribution becomes narrower. This is due to more compact packing of surfactant molecules at high concentrations. The intermicellar distance of around 100 ${\AA}$ above 200 mM corresponds approximately to the diameter of one micelle. The sizes of spherical micelles are 61 ${\AA}$ and 41 ${\AA}$ for 9 mM OTAC and 10 mM ADS, respectively. Also the self-diffusion coefficients by PGSE-NMR yield the apparent sizes 96 ${\AA}$ and 31 ${\AA}$ for micelles of 1 mM OTAC and 10 mM ADS, respectively. For ADS solutions of high concentrations (100-300 mM), DLS data show that the micelle size remains constant at $25{\pm}2{\AA}$. This indicates that the transition in micellar shape does not take place up to 300 mM, which is consistent with the SANS results.

나선형 주사 방법에 의한 고속 NMR 영상화 연구 (High-Speed NMR Imaging by Spiral -Scan Echo Planar Method)

  • 안창범;류충렬;김재호;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1985년도 춘계학술대회
    • /
    • pp.22-25
    • /
    • 1985
  • 본고에서, "나선형 주사 방법에 의한 고속 NMR 영상화" 방법을 제안하고 그에 따른 실험 결과를 보였다. 이것은 2차원 FID 영역을 나선형 궤적으로 스캐닝하며 데이타를 받을 수 있도록 경사 자계 파형 (gradient pulse)을 가하여 빠른 시간에 (수십 msec - 수초)내에 영상 정보를 얻어낸 후, 재구성 알고리즘을 씀으로써 영상을 얻어내는 방법이다. 이 방법의 장점은 첫째로 $T_2$ 감쇄에 의한 PSF (Point Spread Function)가 윈형 대칭으로 주어지므로 영상화 했을때 물체의 구조 식별이 기존의 EPI (Echo Planar Imaging) 방법에 비해서 선명하며, 둘째로 나선형 궤적을 구현하기 의한 경사 자계 파형에서 불연속 점을 없앰과 동시에 파형의 세기가 점차로 증가하는 형태이므로, 기존의, 파형 왜곡에 의해 영상에 미치는 영향을 최소화 할 수가 있으며, 세째로 나선형 스캔을 사이 사이에 끼워 넣는 방법을 씀으로써 해상도를 향상시킬 수가 있다.

  • PDF

Dual contrast MR imaging of liver with superparamagnetic iron oxides and mangafodipir trisodium: Influence of the first on the second contrast agents

  • Kim, Joo-Hee;Kim, Myeong-Jin;Chung, Jae-Joon;Lee, Jong-Tae;Yoo, Hyung-Sik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.109-109
    • /
    • 2001
  • Purpose: To assess the feasibility of sequential administration of ferumoxides and mangafodi trisodium in the same imaging protocols. Method: Thirty patients underwent double-contrast enhanced MR imaging of liver usi ferumoxides (Fe-MRI) and mangafodipir trisodium (Mn-MRI) on 1.5T GE Horizon system. In twenty patients, Mn-MRI was immediately followed by Fe-MRI. In ten patients, Fe-MR was performed first, then Mn-MRI was performed immediately, In all cases, precontras T1-weighted in-phase and opposed-phase spoiled gradient echo (GRE) images an T2-weighted fast spin-echo images (TR 4000ms, TE 102ms, ETL 8-12) were obtained Fe-MRI was performed with FSE and steady state GRE (TE 10 msec, flip angle 30 sequences. Mn-MRI was performed with in-phase and opposed-phase spoiled GR sequences. The SNR changes after the use of each contrast agents were calculated.

  • PDF

고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구 (Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system)

  • 김동혁;고락길;강부민;하동우;손명환;문치웅
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석 (Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI)

  • 이항로;한재용;조민형;임창환;정현교;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.108-115
    • /
    • 2003
  • 목적 : MRI를 촬영하면서 동시에 측정한 뇌전도 신호에 가장 크게 영향을 미치는 것은 경사자계 유발 잡음이다. MRI와 동시에 측정한 뇌전도 신호에서 전류원 국지화를 수행할 때, 경사자계 유발 잡음이 미치는 영향을 분석하고자 한다. 대상 및 방법 : 사람의 머리와 유사하게 만든 뇌전도 팬텀과 MR compatible 뇌전도 측정시스템, 그리고 3.0 Tesla MRI 시스템을 실험에 사용하였다. 3.0 Tesla MRI 시스템 안에 전류원이 설치되어 있는 뇌전도 팬텀을 놓고, EPI 촬영을 하는 동안 뇌전도 신호를 측정하였다. 경사자계의 세기와 전류원의 위치를 조절하면서 뇌전도 신호 측정을 하였고, 측정된 뇌전도 신호에 대하여 전류원 국지화를 수행할 때 나타나는 국지화 오차를 평가하였다. 결과 : 경사자계 유발잡음에 의한 국지화 오차는 경사자계의 세기와 전류원의 위치에 따라 변화하는 것을 관찰하였다. 또한 경사자계 유발잡음이 Gaussian 잡음보다 전류원 국지화에 미치는 영향이 큰 것을 관찰하였으며, 경사자계 유발 잡음의 전력이 뇌전도 신호 전력의 $10\%$ 이하일 때는 전류원 국지화에 미치는 영향이 미미함을 관찰하였다. 결론 : 경사자계 유발 잡음 전력을 뇌전도 신호 전력의 $10\%$ 이하로 줄인다면 MRI를 하면서 동시에 측정한 뇌전도 신호로도 전류원 국지화를 할 수 있음을 알 수 있었다.

  • PDF

Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

  • Abdala-Junior, Reinaldo;No-Cortes, Juliana;Arita, Emiko Saito;Ackerman, Jerome L.;da Silva, Renan Lucio Berbel;Kim, Jun Ho;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.413-419
    • /
    • 2021
  • Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot(P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values(P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

자기공명영상 왜곡에서 마스카라와 아이섀도의 영향 (Effects of the mascara and eye shadow on theMR image distortion)

  • 이현용;신운재;박병래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권1호
    • /
    • pp.25-32
    • /
    • 2005
  • 목 적 : 마스카라와 아이섀도가 자기공명영상 획득시 artifact를 어느 정도 일으키는가를 알아보고, pulse sequence에 따른 영상 왜곡의 차이를 비교하고자 한다. 대상 및 방법 : 실제 국내 여성들이 많이 사용 중인 3개 제조사의 제품 중 마스카라(M1, M2, M3)와 아이섀도(E1, E2, E3)를 선별하여 사용하였다. 자체 제작한 내경이 4 cm, 코일의 길이가 8 cm인 Tx/Rx 겸용의 quadrature type의 안장 코일을 사용하였다. 실험 1에서는 마스카라를 실험 2에서는 아이섀도를 실험 3에서는 마스카라에 아이섀도를 덧바른 후 영상을 획득하였다. Pulse sequence는 FSE(fast spin echo), SE(spin echo), GE(gradient echo)기법을 적용하였으며, 나타난 artifacts는 axial상에서 폭, sagittal상에서 길이를 각각 측정하였다. 각 sequence별로 측정된 영상왜곡 정도를 정량적 및 정성적으로 분석하였다. 결 과 : 마스카라와 아이섀도가 자기공명영상에서 부분적으로 artifact가 발생되어 영상왜곡을 유발하였다. Pulse sequence에 따른 artifact의 유발 정도도 다소 차이가 나타났다. 마스카라에 아이섀도를 덧바른 실험 3에서는 axial상에서 GE sequence에서 16.73 mm, SE에서 6.64 mm, FSE에서 6.19 mm의 폭으로 GE 기법에서 가장 많이 유발되었으며, SE, FSE 기법 순으로 높게 나타났다. sagittal상에서 GE sequence에서 22.84 mm, SE에서 18.15 mm, SE에서 17.81 mm의 길이로 GE 기법에서 가장 많이 유발되었으며, SE, FSE 기법 순으로 낮게 나타났다. 결 론 : 마스카라와 아이섀도로 화장한 여성의 뇌 및 안구 영상검사시 artifact가 영상진단에 영향을 미치는 것으로 판단된다. 뇌 및 안구 T2 강조영상을 얻고자 하는 경우는 pulse sequence를 GE보다 FSE 기법을 사용하는 것이 적합한 것으로 사료된다.

  • PDF

Motion Sensor를 이용한 MBES 오측자료 제거 연구 (A Study on MBES Error Data Removing using Motion Sensor)

  • 강문권;최윤수;장민철;윤하수
    • 한국측량학회지
    • /
    • 제28권1호
    • /
    • pp.39-46
    • /
    • 2010
  • 수심측량 자료는 선박의 항행안전을 위한 필수자료이며 해양의 합리적 이용과 보전을 위한 기초자료이다. 최근 IT기술과 측위장비(GPS와 INS), 수심관측 장비(Echo Sounder)의 발달로 멀티빔(Multi Beam Echo Sounder) 방식을 이용하여 정밀한 해저지형 자료DB를 구축하고 있다. MBES 자료에는 다양한 요인으로 인하여 오차를 포함하고 있으며, 일부 자료에서 지형이 지그재그한 물결현상을 발생하는 오차들이 발생한다. 물결무늬를 발생시키는 오차는 MBES 자료 처리결과의 정확도를 저해하는 요인이며, 발생 원인을 파악하여 이러한 오측자료 제거를 통하여 정확도를 향상시키고자 한다. 본 연구에서는 MBES 자료를 이용하여 물결 무늬 현상이 발생하는 자료에 대한 Motion sensor 값을 분석하여 오측자료의 원인을 파악하였다 분석결과, 물결무늬 현상은 Roll의 표준편차와 상관관계를 갖으며, 이러한 물결무늬 오측자료는 급격한 Roll 값의 변화로 인하여 Swath 자료와 Roll 값의 불일치 결과로 나타났다. 이를 근거로 Swath 자료의 기울기와 Roll 값의 비교하여 오측자료를 선별하여 제거하였다 오측자료를 제거한 결과. Motion sensor의 Roll 값의 표준연차 등을 이용하여 MBES 자료의 품질을 판단하고, 불일치 자료를 최소화하는 추가적인 오차 요인을 계산할 수 있을 것이라 예상된다 또한, 해황조건이 고르지 못한 상황 및 Sensor의 움직임이 크게 일어나는 소형 선박 등에 척용을 하면 수심측량 정확도 개선에 기여할 수 있을 것이다.

단일 RF 펄스를 사용한 3차원 체적 선택 방법을 이용한 MR 스펙트로 스코피 (MR spectroscopy using single-shot RF localization technique)

  • 임채열;천강욱;나종범;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.51-54
    • /
    • 1989
  • 지난 몇년동안 생체에서의 MR 스펙트로 스코피(Mangetic Resonance Spectroscopy)를 위하여 ISIS, VSE, SPARS, STEAM 등과 같은 여러 체적 선택의 방법이 연구되어 왔다. 그러나 이들 3차윈 체적 선택의 방법은 여러 RF 펄스를 사용하여야 되었으며 상대적으로 오랜시간 동안의 RF여기시간(Radio frequency excitation time) 때문에 T1과 T2 감소효과의 영향을 크게 받았다. 본 논문에서는 3차원의 체적을 선택하기 위하여 단일 RF펄스의 사용을 제안하고 있는데, 이 방법은 원통형 체적을 선택하기 위한 방사형 경사 코일 (a radial gradient coil) 방법과 진동자계 (oscillating selection gradient) 방법을 결합하고 있다. 이렇게 하므로 단일 RF 펄스만을 사용하여 체적 선택 시간을 최소화하여 여러 RF 펄스를 사용할 경우 발생하는 파생적인 에코 신호(echo signal)를 피할 수 있었다. 제안된 방법에 의한 실험적 연구결과로서 펜톰(phantom)에 대하여 선택된 체적에 대한 영상과 스펙트럼 (spectrum)을 제시하였다.

  • PDF

1.0 Tesla 자기 공명 진단 장치의 개발 (Development of 1.0 Tesla Compact MRI System)

  • 이흥규;오창현;안창범;장용호;신동희;이근남;장기현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF