• Title/Summary/Keyword: Government office Building

Search Result 145, Processing Time 0.027 seconds

A Study on the Comparison for Energy Consumption Characteristics between G-SEED certified and non-certified Office Buildings in Korea (G-SEED 인증 건축물과 비인증 건축물의 에너지 소비량 특성에 관한 연구 : 업무시설을 대상으로)

  • Kim, Jong-Hyun;Kim, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.33-43
    • /
    • 2019
  • Considerable efforts have been made to reduce greenhouse gas emission around the world to cope with climate change. The government is implementing G-SEED certification to promote energy efficient building design. This study aims to verify the effectiveness of the G-SEED certification system by analyzing the actual energy use of certified and non-certified office buildings. For this purpose, the energy consumption of 135 certified and 142 non-certified office buildings was analyzed according to the seasonal characteristics, building size and number of floors, approval year, and certification grade. The energy saving effects of certified buildings was about 50% higher than that of non-certified buildings. The seasonal energy consumption of buildings is closely related to the heating degree-days. The energy consumption of certified and non-certified buildings decreases with increasing approval year. On the other hand, the energy consumption according to building size and certification grade is not related. This study provides meaningful basic data of G-SEED certification system for future improvement. As the building energy performance standards are strengthened over the years, it is necessary to make the individual score of G-SEED certified projects open to the public to configure the factors of energy efficiency.

A Study on the Characteristics of the Repairs for the Conservation of the Historic Architectures in 1910~1916 - Focused on the Relations with the Activities of the Societies for Historical Property Conservations - (일제강점기 초기 역사적 건조물 보존수리의 특징에 관한 연구 - 고적보존회 활동과의 관련성을 중심으로 -)

  • Seo, Dongchun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.1
    • /
    • pp.33-40
    • /
    • 2018
  • The society for conservation of local historical properties in Korea originated in Japan. It was transplanted by Joseon Governor-General to represent their positions in the field of the conservations of the cultural properties. Also the society for conservation of local historic properties represented the positions of the provincial government office because the representatives of that societies were the chief of local government offices. At that time, the fundamental concept of the historical property conservations was not settled, so they accomplished the conservation activities as the necessary way for themselves.They often made a proposal about repairs for conservation of historical building and suggested a application for the national budget. And they contributed to carry out the repair works of the historical properties in the early Japanese colonial period. But they was usually used to invigorate the tourism and to publicize the regional characteristics through the historical properties. Although the societies were privately-managed as a matter of form, they were governmentally-managed as a matter of fact. It was the limits of the societies for conservation of local historical properties at that time.

An Effect of the Change of Orientation and Window Area Ratio upon Building Energy Requirement in Apartment Housings (공동주택 향별 창면적비 변화에 따른 에너지 영향도 분석)

  • Kim, Jae Moon;Lee, Gyu Chul;Lee, Seung Gyu;Kim, Min Sung;Min, Joon Ki
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.21-26
    • /
    • 2013
  • Due to the increasing concerns about the buildings which have affected the global environment, most countries have enacted a regulation for the sustainability of domestic buildings. In 2008, the Korean government started to enact a regulation of apartment and office buildings for energy saving. Many research on the sustainable apartment building focuses on $84m^2$ or larger type in response to market demand; therefore, small size type such as $46m^2$ type needs to be researched. In addition, the research on the orientation and window to wall ratio of the building have been separately studied as a means of energy reduction; therefore, the research on correlation of the orientation and window to wall ratio hasn't been fully explored yet. This paper analyzes the energy demand of the apartment building as the change of orientation and window to wall ratio among $46m^2$ and $84m^2$ type. In conclusion, when reducing the window to wall ratio, energy demand was reduced, except when the orientation of the building was between from +10 to -20 from the south.

Conceptual Design Strategy of Renewable Energy Application for Building Certification and Mandatory System (신재생에너지설비 건물설치 의무화 및 인증제를 고려한 용량설계 방안)

  • Lee, Kyoung-Ho;Lee, Dong-Won;Kown, Hyeok-Min;Lee, Chang-Jun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.99-104
    • /
    • 2011
  • This paper describes a design strategy at conceptual design stage using RETScreen software tool for building application of renewable energy resources. Currently, government and public buildings are required to adopt renewable energy systems with a minimum requirement for the amount of renewable energy supply. Meanwhile, there is a certificate program for private office buildings to enhance propagation of renewable energy systems. When considering application of renewable energy systems to a building, it is worthwhile developing a method to determine optimal design sizes of renewable energy systems. In the paper, a design strategy is introduced with a couple of case studies to determine optimal capacities of each renewable energy system in a building and suggest to use the method to evaluate the system for the building certificate program and the mandatory renewable target program. Objective functions considered in the study are initial system cost and reduction of CO2 emissions from the system. In the optimization study, it is assumed that solar thermal collectors are installed to satisfy solar fraction of 60%. Other renewable energy systems such as ground-source heat pump, solar PV and non-renewable systems such as electric chiller and gas-fired boiler are sized using an optimal sizing method with RETScreen suggested the authors previously.

  • PDF

Policy to Support the Global Market Entry of the Environmental Industry and Its Future Direction (환경산업 해외시장 진출지원 정책과 향후 지원 방향)

  • Kim, Hong-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.105-115
    • /
    • 2013
  • The Korean government amended the Environmental Technology and Industry Support Act to foster the environment industry and support the advancement of domestic environmental companies into overseas markets. The amended act reflects changes in the government's policies on environment related issues. This paper uses outcomes of research conducted on environmental policies in foreign countries and the current status of the domestic environment industry to present long-term strategic plans and measures to support the expansion of environmental companies into the global markets and to vitalize the environment industry at home. The suggestions for assisting domestic companies in making inroads into overseas markets are as follows: building up and expanding cooperative network; fostering promising companies and exports by making the right choices and focuses; diversification of export markets and strengthening supports for development of new customers; promoting supports for winning overseas projects; and developing cooperative projects to respond to climate change in developing countries using the Global Climate Fund (GCF).

An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements - (공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 -)

  • Cho, Jung-Chul;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF

Building Surveys and Nationalization on Royal Facilities During the Residency-General Period (1906~1910) (통감부 시기 황실시설의 조사와 국유화)

  • Lee, Geau-Chul
    • Journal of architectural history
    • /
    • v.22 no.4
    • /
    • pp.59-72
    • /
    • 2013
  • Jedoguk and Jaesiljaesanjeongriguk were the offices related to the reorganization of the royal finance during the Residency-General period and surveyed royal facilities. Jedoguk surveyed palaces, offices and royal ritual facilities in the manner of traditional survey. However, Jaesiljaesajeongriguk which is the successor office to Jedoguk surveyed royal facilities using the modern surveying techniques and figured out the value of royal facilities. In 1908, most of the royal facilities were nationalized and were managed as government property by Takjibu. These nationalized royal facilities were used new modern facilities under the rule of Japanese.

A Fundamental Study on International Comparison of Labor Productivity in Construction Industry (건설업 노동생산성의 국제비교에 관한 기초 연구)

  • Park, Hwan-Pyo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.310-311
    • /
    • 2018
  • This study compared the labor productivity of the construction industry to the manufacturing and service industries. In addition, It analyzed the construction labor productivity gap of the G7 countries based on data from the Korean Productivity Center. A comparative analysis of construction labor productivity between manufacturing and service industries, based on statistics from the National Statistical Office, revealed a relatively low level and trend of continued decline. In addition, a comparative analysis of the productivity of construction workers in the major G7 countries found that the difference in productivity is very large, with an average of 65.3 %. Therefore, domestic construction companies and the government should prepare Improvement measures to improve productivity by investing in technology development to increase labor productivity and improving the production system of the construction industry.

  • PDF

A Model Feasibility Analysis of Commerce Building (상업건축물의 사업타당성 분석 모형 구축)

  • Kook, Dong-Hoon;Son, Ki-Young;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.7 no.3
    • /
    • pp.71-79
    • /
    • 2007
  • The starting point of successful building production process is the feasibility study of the project. If the feasibility study is poor which is affected in direct production processes such as designing and engineering, it incurs a great unrecoverable loss to the company. The government institutionalized the feasibility study for projects that budgets over 50billion won in an effort to ensure competitiveness of the construction industry after IMF; however, the system and effort to created systematic studies or guidance preparation for private construction development projects are lacking in great deal. Therefore, the objective of this study is to establish the analysis factors of feasibility study and evaluation standard by systematic analysis in consideration of the changes of various variables and mutual relationships using system dynamics technique for office buildings among commercial buildings.

Improvement Devices of Urban Center′s Green Function of the Public Open Space Attached Building in Incheon, Korea (인천시 공개공지의 도심 녹지 기능 개선 방안)

  • Cho, Woo;Lee, Yong-Joo;Lee, Kyung-Jae
    • Korean Journal of Environment and Ecology
    • /
    • v.17 no.3
    • /
    • pp.258-267
    • /
    • 2003
  • The purpose of this study is to present improvement devices of urban center's green function in the Public Open Space Attached Building(P.O.S.) in Incheon, Korea. Study sites were the P.O.S. of office building(10 place), transportation facility building(3 places), government office building(2 places) that were made up 1994∼2002 and analyzed establishment, using and planting status. And P.O.S.'s planting area structure of Osaka and Kawasaki in Japan that is operating P.O.S. system similar to Korea was compared with study sites of Incheon. P.O.S. of Incheon is not managing as valuable urban center's green and establishing to satisfy legal requirement. The strengthening devices of P.O.S. function are as follows. First, it is desirable that planting area rate of P.O.S. in order to develop small park in urban center is increasing by 40% that is children's park level. Second, it must be conferred about planting basis, tree selection and planting method etc. of P.O.S. with green and park development department at building authorization. Third, by the 'landscape planting standard of plottage' that is becoming planting standard of P.O.S is heightened and must increase quality and amount of green. Fourth, it is required mandatory establishing of sign so that citizens can search easily and utilize of P.O.S. Fifth, legal regulation should be decided to prevent that P.O.S. is used unlike purpose originally.