• Title/Summary/Keyword: Goniometry

Search Result 18, Processing Time 0.025 seconds

Assessments of Physical Workload in Sonography Tasks Using Inclinometry, Goniometry, and Electromyography

  • Simonsen, Jenny Gremark;Dahlqvist, Camilla;Enquist, Henrik;Nordander, Catarina;Axmon, Anna;Arvidsson, Inger
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.326-333
    • /
    • 2018
  • Background: Echocardiography involves strenuous postures of the upper limbs. This study explored the physical workload in the neck and upper limbs in sonographers performing echocardiography, and the extent to which the workload differs from than in other work tasks (other sonographic examinations, and nonsonographic tasks). Methods: The physical load was assessed by inclinometry, goniometry, and electromyography methods in 33 female sonographers during authentic work using three different echocardiography techniques and other work tasks. Results: Echocardiography was characterized by low velocities of the head, arms, and wrists, and a low proportion of muscular resting time in the forearms, in the transducer limb, and the computer limb. The transducer limb was more elevated in one of the techniques, but this technique also involved a higher proportion of muscular resting time of the trapezius muscle. We also found a high proportion of awkward wrist postures in the transducer wrist in all three techniques; in one due to prolonged flexion, and in the others due to prolonged extension. Other work tasks were less static, and were performed with higher upper arm and wrist velocities. Conclusion: None of the three echocardiography techniques was optimal concerning physical workload. Thus, to achieve more variation in physical load we recommend that the equipment be arranged so that the sonographer can alternate between two different techniques during the workday. We also propose alternation between echocardiography and nonsonographic tasks, in order to introduce variation in the physical workload. Clinical expertise should be used to achieve further improvements.

Uniform Grafting of Poly(1,5-dioxepan-2-one) by Surface-Initiated, Ring-Opening Polymerization

  • Yoon Kuk-Ro;Yoon Ok-Ja;Chi Young-Shik;Choi Insung-S.
    • Macromolecular Research
    • /
    • v.14 no.2
    • /
    • pp.205-208
    • /
    • 2006
  • A polymeric film of a biodegradable poly(1,5-dioxepan-2-one) (PDXO) was formed on a gold surface by a combination of the formation of self-assembled monolayers (SAMs) presenting hydroxyl groups and the surface-initiated, ring-opening polymerization (SI-ROP) of 1,5-dioxepan-2-one (DXO). The SI-ROP of DXO was achieved by heating a mixture of $Sn(Oct)_2$, DXO, and the SAM-coated substrate in anhydrous toluene at $55^{\circ}C$. The resulting PDXO film was quite uniform. The PDXO film was characterized by polarized infrared external reflectance spectroscopy, X-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectrometry, atomic force microscopy, ellipsometry, and contact angle goniometry.

Mussel-Inspired, Fast Surface Modification of Solid Substrates

  • Hong, Sang-Hyeon;Kang, Sung-Min;Lee, Hae-Shin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.201-201
    • /
    • 2011
  • Recently, mussel-inspired surface modification, called polydopamine coating has been extensively implemented to many areas, due to its material versatility and ease to use. In particular, incubation of substrates in an alkaline dopamine solution resulted in self-polymerization of dopamine and modified variety of material surfaces, including noble metals, metal oxides, ceramics, and synthetic polymers. However, the polydopamine coating has a drawback to practical use; it takes more than 12 hrs to introduce sufficient polydopamine layers to solid substrates. Here, we investigated the rate-enhanced polydopamine coating by varying reaction conditions: pH, concentration, and the addition of the oxidizing agent. As a result, the optimum condition for fast polydopamine coating was found, and solid substrates were efficiently coated with polydopamine layers in just few minutes using the condition. The polydopamine-modified surface was characterized by XPS and contact angle goniometry, and the biocompatibility of the modified surface was also proved by cell attachment test.

  • PDF

Synthesis of Thiol-Functionalized Ionic Liquids and Formation of Self-Assembled Monolayer on Gold Surfaces: Effects of Alkyl Group and Anion on the Surface Wettability

  • Lee, Bang-Sook;Lee, Sang-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1531-1537
    • /
    • 2004
  • Twenty four thiol-functionalized ionic liquids based on imidazolium cation, 1-(12-mercaptododecyl)-3-alkylimidazolium salts, have been synthesized, and utilized to investigate the effects of alkyl-chain length and anion on the wettability of Au surfaces on the basis of self-assembled monolayers presenting [(CnSAMIM)X], where n = 1-6, X = Br, $BF_4$, $PF_4$ and $NTf_2$. Water wettabilities of the surfaces were measured as a water contact angle by contact angle goniometry. It was found that water wettability of the Au surfaces coated with imidazolium ions was largely dependent not only on counter anions but also on the length of alkyl chains. In the case of SAMs of N-alkylimidazolium ions having short length of N-alkyl chain (C1-$C_4$), anions played great role in determining water wettability of the surfaces.

Characterization of Surfaces by Contact Angle Goniometry - II . Effect of Curvature on Contact Angle - (접촉각 측정에 의한 표면의 특성연구( II ) -섬유나 막대의 직경이 접촉각에 미치는 영향-)

  • Park Chung Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.4 s.40
    • /
    • pp.437-445
    • /
    • 1991
  • The effect of diameter of rods or fibers on contact angle was studied in a vertical rod configuration. A contact angle measuring device described in the previous paper was optimized for the measurement of small-diameter fibers. It was shown that contact angles of water and hexadecane on nylon 6 monofilsments and glass rods increased with decrease of diameter below a critical diameter, which varied from one system to another. Beyond the critical value, contact angle of the liquid on the vertical glass rod reached to an equilibrium value which is equal to the unique value of the contact angle of the liquid drop on the horizontal glass plate.

  • PDF

Characterization of Surfaces by Contact Angle Goniometry - I. Contact Angle Measurement by Laser Beam Projection- (접촉각측정에 의한 표면의 특성연구 - I. 레이저광선 투영에 의한 접촉각의 측정방법-)

  • Park Chung Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.1
    • /
    • pp.70-75
    • /
    • 1991
  • Contact angle measuring device was developed in this laboratory using laser beam projec-tion. The new method allows for rapid and direct determination of stationary, advancing, and receding contact angles on both planar and nonplanar solid surfaces, including fibers with very small diameters. A narrow laser beam impinges on an edge of an interface of liquid and solid. This makes two projected laser beam lines upon and radiating from the center of a protractor scale on a tangent screen. Contact angle is measured by determining the difference in angle on the protractor scale between the two projected laser beam lines. Contact angles measured on Perspex-CQ using this instrument were in agreement with the literature. it was shown that this instrument provides a novel method for the facile and accurate measurement of contact angles.

  • PDF

Reliaility of Goniometric Measurements of Shoulder Joint Range of Motion (측각기를 사용한 견관절 운동범위 측정의 신뢰도에 관한 연구)

  • Lee, So-Joon;Hur, Young-Gu
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.917-921
    • /
    • 2001
  • The purpose of this study was to examine the difference in measurements of passive range of motion(PROM) of shoulder when motions are assessed in sitting, as compared with supine and the intratester and intertester reliabilities for goniometric measurements of shoulder PROM using two different sizes of goniometers. * A thesis submitted to the committee of Graduate School of Public Health, Chungnam National University in partial fulfillment of the requirements for the degree of Master of Public Health conferred in February 2001. Fifty one adult male subjects were measured three times, in random order, for the six shoulder motions(flexion, extension, abduction, adduction, external rotation, and internal rotation) while sitting and supine by three different therapists. Data were analyzed to determine intraclass correlation coefficients (ICCs) and paired "t" values between trials for measurements with different goniometer and betweensitting and supine trials. There was statistical difference in measurement of shoulder motion between supine and sitting position and no statistical difference in goniometric type. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .98. The ICCs for the intertester reliability of PROM measurements of all shoulder motion ranged from .26 to .89. These findings suggest that reliable measures of PROM of the shoulder can be obtained using standard goniometry in a proper position.

  • PDF

Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement (고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성)

  • Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.1
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.

In-situ modification of PVC UF membrane by SiO2 sol in the coagulation bath during NIPS process

  • Cheng, Liang;Xu, Zhen-Liang;Yang, Hu;Wei, Yong-Min
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.317-325
    • /
    • 2018
  • Polyvinyl chloride (PVC) ultrafiltration (UF) membrane was modified by silica sol in the coagulation bath during non-solvent induced phase separation (NIPS) process. The effects of silica sol concentrations on the morphology, surface property, mechanical strength and separation property of PVC UF membranes were systematically investigated. PVC membranes were characterized by Fourier transform infrared spectroscopy (FTIR), energy dispersive spectroscopy (EDS), scanning electron microscopy (SEM), contact angle goniometry and tensile strength measurement. The results showed that silica had been successfully assembled on the surface of PVC UF membrane. With the increase of silica sol concentration in the coagulation bath, the morphologies of PVC UF membranes changed from cavity structure to finger-like pore structure and asymmetric cross-section structure. The hydrophilicity and permeability of PVC UF membranes were further evaluated. When silica sol concentration was 20 wt.%, the modified PVC membrane exhibited the highest hydrophilicity with a static contact angle of $36.5^{\circ}$ and permeability of $91.8(L{\cdot}m^{-2}{\cdot}h^{-1})$. The structure of self-assemble silica had significant impact on the surface property, morphology, mechanical strength and resultant separation performance of the PVC membranes.

Correlation of Hip Joint Range of Motion and Femur Head Anterior Glide Mobility with Gait Ability in Stroke Patients (뇌졸중 환자의 고관절 관절가동범위와 대퇴골두 전방가동성, 보행 능력간에 상관관계)

  • Kim, Young-Hoon;Kim, Suhn-Yeop;Jang, Hyun-Jung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.35-44
    • /
    • 2014
  • PURPOSE: The aim of the study was to investigate the relationships among the hip joint passive range of motion (ROM) and femur head anterior glide (FHAG) mobility on the gait ability in patients with post-stroke hemiparesis. METHODS: The participants were 37 patients (30 male, 7 female) living in Daejeon. The ROM of the hip joint was measured by using goniometry and the FHAG mobility was measured by using the Prone Figure-4 test. The walking ability was assessed by using the 10m walk test (10MWT), and the 6-min walk test (6MWT). RESULTS: The FHAG was negatively correlated with hip extension (r=-.554, p<.05) and flexion (r=-.337) on the affected side as well as with hip extension (r=-.480), abduction (r=-.361), and adduction (r=-.426) on the non-affected side (p<.05). The gait ability was correlated with the hip joint external rotation on the non-affected side (p<.05), but showed no significant correlation with the hip ROM on the affected side (p>.05). CONCLUSION: This study provides evidence that in patients with post-stroke hemiparesis, the FHAG mobility might be correlated with hip extension. Based on these results, the FHAG mobility may be used to determine the hip extension in patients with post-stroke hemiparesis.