• 제목/요약/키워드: Gold surfaces

검색결과 155건 처리시간 0.02초

치과용 합금의 표면 처리가 글라스아이오노머 시멘트와 폴리카르복실레이트 시멘트의 결합력에 미치는 영향 (INFLUENCE OF SURFACE TREATMENTS OF DENIAL ALLOYS ON BOND STRENGTH OF GLASS IONOMER AND POLYCARBOXYLATE CEMENT)

  • 이헌우;우이형;임호남;최부병
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.125-142
    • /
    • 1996
  • Bond strength of four different cements to dental casting alloys which were treated with #600 emery, tin-plating, and $50{\mu}m$ sandblasting were evaluated. The alloy specimens were Type III Gold alloy(Degulor C), Palladium-Silver alloy(Pors on 4), Nickel-Chromium(Rexillium III) alloy, which were embedded in acrylic resin disc. The specimens were treated with #600 emery and tin plating, #600 emery and sandblasting, then bonded using Fuji I, Ketac Cem(Glass ionomer cements), Poly F, Livcarbo(Polycarboxylate cements). The specimens were immersed in water for 24 hours and shear bond strengths were evaluated by Instron Machine. Tin plated, sandblasted, and debonded alloy surfaces were observed using scanning electron microscope. On the basis of this study, the following conclusions could be drawn. 1. In the tin plated alloy group, increase in bond strength of glass ionomer cements was statistically insignificant. 2. In the tin plated alloy group, increase in bond strength of polycarboxylate cements was statistically significant, except nickel-chromium alloy. 3. Sandblasted alloy group showed higher bond strength than that of tin-plated alloy group.

  • PDF

Formation and Annealing Effect of Tolanethioacetate Self-Assembled Monolayers on Au(111)

  • Jeong, Young-Do;Han, Jin-Wook;Kim, Nak-Joong;Lee, Young-Il;Lee, Chang-Jin;Hara, Masahiko;Noh, Jaeg-Eun
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2445-2448
    • /
    • 2007
  • Self-assembled monolayers (SAMs) were formed by adsorption of thioacetyl-terminated tolanethioacetate (TTA) on Au(111) in a 0.5-mM ethanol solution after one day immersion at room temperature. Molecular-scale STM imaging revealed that the TTA SAMs were composed of two mixed phases; an ordered phase with small domains describing a ( × 2 )R30° structure and a disordered phase. Interestingly, after annealing the precovered TTA SAMs on Au(111) at 90 °C for 1 h, the small ordered domains grew unidirectionally, resulting in the formation of unique rod-like domains, which were assigned a ( × 2 )R7° structure. These results will be very useful in understanding the formation and thermal behavior of TTA SAMs on gold surfaces.

전해질 변화에 따른 Viologen 자기조립박막의 전하이동 특성 연구 (Electron-transfer Properties of Viologen Self-assembled MonoLayers in Different Electrolyte Solutions)

  • 이동윤;박상현;신훈규;박재철;장정수;권영수
    • 한국전기전자재료학회논문지
    • /
    • 제17권12호
    • /
    • pp.1337-1340
    • /
    • 2004
  • The self-assembled monolayers of alkane derivatives with sulfur containing head groups on gold substrates have been widely examined recently, since the binding between S atoms and Au surface is strong. The viologen has been widely investigated their well-behaved electrochemistry including electron transfer mediation, the surface-enhanced of the adsorption and the behavior of supramolecular assemblies at electrode surfaces in theses and various studies. Yiologen monolayers are formed onto QCM by self-assembly method. We studied the relationship of electron transfer from changing the anions in 0.1 M NaCl and NaClO$_4$ electrolyte solution. The EQCM measurements revealed the anions transfer during reduction and oxidation, respectively From the EQCM data, the well-defined shape peaks were nearly equal charges by cyclic voltammetry.

치과 보철용 금속 합금의 마찰 마멸 특성 (Tribological Characteristics of Dental Metal Alloys)

  • 김종훈;최원식
    • Tribology and Lubricants
    • /
    • 제29권4호
    • /
    • pp.235-241
    • /
    • 2013
  • The tribological characteristics of dental metal alloys and zirconia were studied by carrying out a friction and wear performance test. In this study, a pin-on-disk-type tester was used and dead weight was employed as the normal load applied to the test specimen. The friction coefficient of dental metal alloys was investigated in terms of their weight and sliding velocity. Microscopic observations were carried out on worn surfaces of specimens. The results indicated that among all metal alloys, Super-A had the highest friction coefficient. Super-A had the lowest amount of wear among all metal alloys, and the amount of wear increased in the following order: Crown & Bridge, Porcelain, and Partial. Crown & Bridge had the best friction coefficient, but the hardness of Crown & Bridge was lower than that of Porcelain and Partial. Experimental measurement results indicated that the disk weight before and after the experiment was the same.

Development of piezoelectric immunosensor for the rapid detection of marine derived pathogenic bacteria, Vibrio vulnificus

  • Hong, Suhee;Jeong, Hyun-Do
    • 한국어병학회지
    • /
    • 제27권2호
    • /
    • pp.99-105
    • /
    • 2014
  • Biosensors consist of biochemical recognition agents like antibodies immobilized on the surfaces of transducers that change the recognition into a measurable electronic signal. Here we report a piezoelectric immunosensor made to detect Vibrio vulnificus. A 9MHz AT-cut piezoelectric wafer attached with two gold electrodes of 5mm diameter was used as the transducer of the QCM biosensor with a reproducibility of ${\pm}0.1Hz$ in frequency response. We have tried different approaches to immobilize antibody on the sensor chip. Concerning the orientation of antibody for the best antigen binding capacity, the antibody was immobilized by specific binding to protein G or by cross-linking through hydrazine. In addition, protein G was cross-linked on glutaraldehyde activated immine layer (PEI) or EDC/NHS activated sulfide monolayer (MPA). PEI was found to be more effective to immobilize protein G following glutaraldehyde activation than MPA. However, hydrazine chip showed a better capability to immobilize more IgG than protein G chip and a higher sensitivity. The sensor system was able to detect V. vulnificus in dose dependent manner and was able to detect bacterial cells within 5 minutes by monitoring frequency shifts in real time. The detection limit can be improved by preincubation to enrich the bacterial cell number.

레이저 형광 원리를 이용한 우식 진단 기기의 구치부 인접면 우식 진단 능력 비교 (Comparison of Diagnostic Validity between Laser Fluorescence Devices in Proximal Caries)

  • 이창근;이대우;김재곤;양연미
    • 대한소아치과학회지
    • /
    • 제45권4호
    • /
    • pp.426-435
    • /
    • 2018
  • 이 연구의 목적은 두 가지 형태의 레이저 형광원리를 이용한 우식 진단 기기(DD, DDpen)의 구치부 인접면 우식을 진단 하는 능력을 비교하고, 두 기기의 최적의 절단값을 확인하는 것이다. 이 연구에는 164개의 유구치 인접면과 438개의 영구치 구치부 인접면이 연구 대상에 포함되었다. 각 치면은 순서대로 두 가지 기기를 통한 검사를 시행하였고, 두 기기를 비교할 기준으로서 교익 방사선 사진 촬영을 시행하였다. 방사선 사진 촬영 결과는 우식의 깊이에 따라 유치열 3개의 군($pR_0$, $pR_1$, $pR_2$), 영구치열 4개의 군($PR_0$, $PR_1$, $PR_2$, $PR_3$)으로 분류하였다. 유치열에서 법랑질 우식과 상아질 우식의 AUC 값은 DD가 각각 0.851과 0.890으로 나타났고, DDpen은 각각 0.883과 0.917로 나타났다. 영구치열에서 법랑질 우식과 상아질 우식의 AUC 값은 DD가 각각 0.762과 0.886으로 나타났고, DDpen은 각각 0.828과 0.958로 나타났다. 유치열과 영구치열 모두 구치부 인접면 우식을 검사하는 데에는 DDpen이 DD보다 정확한 결과를 보였다. 하지만 유치열에 대해서는 DD도 인접면 우식 검사에 활용이 가능할 것으로 보인다.

금인레이의 치은변연적합도에 관한 주사전자 현미경적 연구 (SCANNING ELECTRON MICROSCOPIC STUDY OF THE JUNCTION BETWEEN GOLD INLAYS AND GINGIVAL CAVOSURFACE MARGINS)

  • 박준일;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.43-61
    • /
    • 1991
  • Present - day inlay casting procedures have been developed for more than 100 years and experimentation has focused on the perfect adaptation to the cavity preparation. Marginal adaptation is considered to be an important indicator of the acceptability of the cast restotration, especially on the gingival margin. The purpose of this study was to evaluate the effects of a dissecting microscope and burnishing on vertical discrepancies, horizontal discrepancies, and cement thicknesson master die. Extracted premolars were prepared for class II gold inlays and master dies were made with conventional techniques. The experiments consisted of 4 groups. Group 1 : unaided eye, no burnishing on master die. Group 2 : unaided eye, burnishing on master die. Group 3 : microscope, no burnishing on master die. Group 4 : microscope, burnishing on master die. Cemented inlays were embedded in the hard resin and sectioned with microcutter through the gingival margins. The sectioned surfaces were polished with emery paper and finally with aluminum oxide powders. The results of the experiments were measured for vertical discrepancies, horizontal discrepancied and cement thickness under the scanning electron microscpe at the beveled gingival margin. The results of the study were summarized as follows. 1. Group 1 showed the vertical discrepancies of $81.6{\mu}m({\pm}48.6{\mu}m)$, horizontal discrepancies of $60.1{\mu}m({\pm}41.1{\mu}m)$, and cement thickness of $59.6{\mu}m({\pm}24.6{\mu}m)$. 2. Group 2 showed the vertical discrepancies of $78.6{\mu}m({\pm}30.9{\mu}m)$, horizontal discrepancies of $36.9{\mu}m({\pm}20.7{\mu}m)$, and cement thickness of $54.0{\mu}m({\pm}21.6{\mu}m)$. 3. Group 3 showed the vertical discrepancies of $57.5{\mu}m({\pm}26.4{\mu}m)$, horizontal discrepancies of $28.4{\mu}m({\pm}17.5{\mu}m)$, and cement thickness of $37.2{\mu}m({\pm}17.4{\mu}m)$. 4. Group 4 showed the vertical discrepancies of $56.7{\mu}m({\pm}35.0{\mu}m)$, horizontal discrepancies of $31.8{\mu}m({\pm}24.2{\mu}m)$, and cement thickness of $45.6{\mu}m({\pm}19.8{\mu}m)$. 5. Vertical discrepancies were not significantly different at any groups(p>.050). 6. Microscope groups(Group 3, 4) showed significantly improved horizontal marginal adaptation (p<.050). 7. Although cement thickness showed the subset of Group 3. 4, 2 and Group 4, 2, 1. Group 3 showed significantly smaller thickness than Group l(p<.050). 8. Finishing and polishing by means of a microscope produced significantly smaller discrepancies than doing so with the unaided eye(p<.050).

  • PDF

고속전단 시험을 이용한 Sn-37Pb BGA solder joints의 기계적 신뢰성 특성 평가 (Mechanical reliability of Sn-37Pb BGA solder joints with high-speed shear test)

  • 장진규;하상수;하상옥;이종근;문정탁;박재현;서원찬;정승부
    • 마이크로전자및패키징학회지
    • /
    • 제15권4호
    • /
    • pp.65-70
    • /
    • 2008
  • 본 연구에서는 BGA(Ball Grid Array) 솔더 접합부에 high impact가 가해졌을 경우 접합부의 기계적 특성에 대해서 연구하였다. 시편은 ENIG(Electroless Nickel Immersion Gold) 표면 처리된 FR-4 기판 위에 직경이 500 ${\mu}m$인 Sn-37Pb 솔더볼을 BGA 방식으로 배열하고 리플로우(Reflow)를 통하여 제작하였다. HTS(High Temperature Storage) 테스트를 위해, 시편을 일정한 온도의 $120^{\circ}C$에서 250시간 동안 시효처리(Aging)를 실시하였다. 시효처리 후, 각각의 시편은 고속 전단 시험기(Dage-4000HS)를 이용하여 속도 변수는 0.01, 0.1, 1, 3 m/s로 설정하여 고속전단 시험을 실시하였다. 전단시험 후, 솔더 접합 계면과 파면을 주사전자현미경(Scanning Electron Microscope, SEM)을 통하여 관찰하였다. 솔더 접합 계면에는 $Ni_3Sn_4$의 금속간 화합물이 성장하였으며, 시효처리 후, 솔더 접합 계면에 생성된 금속간 화합물의 두께가 증가하는 것을 관찰 할 수 있었다. 전단 시험 결과, 전단 속도가 빨라짐에 따라 전단 강도값은 증가하는 경향을 나타내었다. 솔더 접합부의 파단은 전단 속도와 시효처리 시간에 따라 다양한 파괴 모드로 진행됨을 알 수 있었다. 또한, 파괴 모드는 연성파괴 형상을 보이다가 전단속도가 증가함에 따라 취성 파괴 형상으로 변하는 것을 알 수 있었다.

  • PDF

상이질 접착제의 적용방법에 따른 전단결합강도와 접착양상에 관한 연구 (INFLUENCE OF APPLICATION METHODS OF A DENTIN ADHESIVE ON SHEAR BOND STRENGTH AND ADHESIVE PATTERN)

  • 박성택;문주훈;조영곤;온영석
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.381-391
    • /
    • 1999
  • A new 5th generation adhesive system(ONE-STEP) has been supplied which operators can apply to conditioned tooth surfaces by one simplified step. The purpose of this study was to determine whether different methods of adhesive application and various air drying duration after applying adhesive affect the shear bond strength of composite resin to dentin, and to evaluate the adhesive pattern of composite resin and dentin under SEM. Seventy-seven extracted human molar teeth were cleaned and mounted in palstic test tubes. The occlusal dentin surfaces were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A.). Teeth were randomly divided into 7 groups (n=11), In experimental A group, adhesive was applied to dentin with agitation for 20 sec. In experimental N-A group, adhesive were continuously applied to dentin for 20 sec. Also control and experimental 1, 2, 3, 4 groups were dried for 10, 0, 5, 20, 30 seconds after applying adhesive, respectively, Adhesives were light cured for 10 sec. A gelatin capsule 5mm in diameter was filled with Aelitefil$^{TM}$ composite resin, placed on the treated dentin surface and light cured for 40 see, from three sides, All specimens were stored in distilled water at room temperature for 24 hours. The shear bond strengths were measured using a universal testing machine(AGS-1000 4D, Japan) at a crosshead speed of 5mm/min. An one-way ANOVA and LSD test were used for statistical analysis of the data. For SEM evaluation, seven specimens were made and sectioned. Representive postfracture and seven specimens were mounted on brass stubs, sputter-coated with gold and observed under SEM. The results were as follows : 1. The shear bond strength of experimental A group which adhesive were applied to dentin with agitation was higher than that of experimental N-A group (continuous application), and there was significant difference between two groups (p<0.01). 2. The interface between composite and dentin according to different application methods showed close adaptation in experimental A group and showed tinny gap in experimental N-A group. 3. The shear bond strength accoding to various air drying duration was the lowest value(7.57${\pm}$2.60 MPa) in experimental 1 group, so there was significant difference between experimental 1 group and other four groups (p<0.05). But there was no significant difference of shear bond strength between four groups (p>0.05). 4. The interface between composite and dentin according to various air drying duration showed close adaptation in control group and tinny gap in experimental 3 and 4 groups. But experimental 1 and 2 groups showed $30{\mu}$ and 6 - $10{\mu}m$ thick gaps, respectively.

  • PDF

수종 상아질접착제의 상아질침투양상에 관한 주사현미경적 연구 (SCANNING ELECTRON MICROSCOPIC STUDY ON RESIN INFILTRATIONS AFTER DENTIN TREATMENTS)

  • 권균원;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.38-53
    • /
    • 1993
  • The purpose of this study was to observe the resin infiltration pattern into dentin by various dentin bonding agents. Freshley extracted 36 sound human molars were used in this study. They were stored at $4^{\circ}C$ physiologic saline solution before experiment. All the teeth were cross-sectioned to expose dentin below about 3.0mm at the cusp tip and above 2.0mm at the cemento-enamel junction with Crystal Cutter (MC411 D, Maruto Co., Japan), and were made into specimens for this study (Fig. 1). The specimen experimental groups were divided into 9 groups by dentin surface treatment as following procedures: Group I: Treated with Gluma Cleanser followed by Gluma Primer and Sealer Group 2. Treated with Gluma Cleanser followed by Scotch bond 2 Adhesive Group 3: Treated with Gluma Cleanser followed by Tenure Solution A, Band Visar Seal Group 4: Treated with Scotchprep followed by Scotch bond 2 Adhesive Group 5: Treated with Scotchprep followed by Gluma Primer and Sealer Group 6: Treated with Scotch prep followed by Tenure Solution A, Band Visar Seal Group 7: Treated with Tenure Conditioner followed by Tenure Solution A, Band Visar Seal Group 8: Treated with Tenure Conditioner followed by Scotchbond 2 Adhesive Group 9: Treated with Tenure Conditioner followed by Gluma Primer and Sealer 27 specimens of 36 specimens were divided into 9 groups (Group 1-9), and were used for observation of resin tags. Remaining 9 specimens were divided into 3 groups (Group 1,4 and 7), and were used for observation of fractured dentin surfaces. Specimens to observe the resin tag were demineralized with 20% HCl for 14 hours, specimens to observe the fractured dentin surfaces were demineralized with 10% HCl for 3 minutes. All the specimens were gold-coated with Eiko ion coater (Eiko-engineering Co.), and observed under Scanning electron microscope (Hitachi S-2300) at 20 KV. The following results were obtained: 1. In group 1 treated with Gluma Cleanser, Gluma Primer, and Sealer, most resin tags were more than $100{\mu}m$. 2. In group 4 treated with Scotch prep and Scotchbond 2 Adhesive, most resin tags were about $10{\mu}m$. 3. In group 7 treated with Tenure conditioner, Tenure Solution A, B, and Visar Seal, most resin tags were about $10{\mu}m$ but occasionally resin tags were more than $100{\mu}m$. 4. In groups 2,3,5,6,8 and 9, the lengths of resin tags were inconsistent and the amount of resin tags were reduced.

  • PDF