• 제목/요약/키워드: Gold surfaces

검색결과 155건 처리시간 0.028초

표면 촉매 화학 반응을 이용한 크기 조절이 가능한 홀 어레이 제작 (Fabrication of Size-Controlled Hole Array by Surface-Catalyzed Chemical Deposition)

  • 박형주;박정원;이대식;표현봉
    • 센서학회지
    • /
    • 제27권1호
    • /
    • pp.55-58
    • /
    • 2018
  • Low-cost and large-scale fabrication method of nanohole array, which comprises nanoscale voids separated by a few tens to a few hundreds of nanometers, has opened up new possibilities in biomolecular sensing as well as novel frontier optical devices. One of the key aspects of the nanohole array research is how to control the hole size following each specific needs of the hole structure. Here, we report the extensive study on the fine control of the hole size within the range of 500-2500 nm via surface-catalyzed chemical deposition. The initial hole structures were prepared via conventional photo-lithography, and the hole size was decreased to a designed value through the surface-catalyzed chemical reduction of the gold ion on the predefined hole surfaces, by simple dipping of the hole array device into the aqueous solution of gold chloride and hydroxylamine. The final hole size was controlled by adjusting reaction time, and the optimal experimental condition was obtained by doing a series of characterization experiments. The characterization of size-controlled hole array was systematically examined on the image results of optical microscopy, field emission scanning electron microscopy(FESEM), atomic-force microscopy(AFM), and total internal reflection microscopy.

치과용 지르코니아 이장재 처리에 따른 지르코니아와 도재의 전단결합강도 비교 (Shear bond strength of a layered zirconia and porcelain according to treatment of zirconia liner)

  • 서정일;박원욱;김양근
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.43-52
    • /
    • 2017
  • Purpose: Physical and chemical properties of gold is most suitable to be restored of teeth to its original state. Recently zirconia was used instead of gold because of esthetical and intimacy of human body. Because of high strength and high abrasion resistance of zirconia, all zirconia artificial tooth lead to wear the original tooth of opposite site. To preserve this original tooth, zirconia artificial tooth covered with dental ceramic glass was used. When joining the zirconia core and dental ceramic glass, difference of their thermal expansion coefficient and wetting ability is generated the residual stress at interface lead to crack. In order to solve this problem, intermediate layer what is called zir-liner was imported to decrease the residual stress and increase the bonding strength. Methods: In this study, to identify the optimum conditions for manufacturing process, various methods to rough the surface of zirconia core were adopted, and vary the thickness of interlayer, and analyzed bond strength. Results: Bond strength of sanding specimens group showed higher than that of non-sanding specimens group, and once applied intermediate layer with sanding specimens showed highest bond strength with 28 MPa. SEM photomicrographs of zirconia cores fired at $1500^{\circ}C$ showed parallel straight lines in sanding and pockmarked surface in blasting surfaces as abrasion traces. Observation of the destruction section after shear test by SEM were carried out. Liner applied non-sanding group and non-liner applied sanding group all showed interfacial crack. Sandblasting group with non-liner showed remained dental ceramic glass on the surface of zirconia. Sandblasting group with once applied liner showed partially remained liner and dental ceramic glass on the surface of zirconia. XRD analysis revealed that sandblasting group showed higher monoclinic peaks than other specimens group and this result was due to the high collision energy for stress induced phase transformation. Conclusions: A study on the improvement of bonding strength between zirconia and dental ceramic glass steadily carried out for the future to practical use.

나노입자 마스크를 이용하여 제작한 초소수성 마이크로-나노 혼성구조 (Fabrication of Superhydrophobic Micro-Nano Hybrid Structures by Reactive Ion Etching with Au Nanoparticle Masks)

  • 이초연;윤석본;장건익;윤완수
    • 한국진공학회지
    • /
    • 제19권4호
    • /
    • pp.300-306
    • /
    • 2010
  • 소수성 고분자를 사용하여 제작한 마이크로구조에 금 나노입자를 마스크로 이용하는 반응성이온식각(RIE: Reactive Ion Etching)을 적용하여 초소수성을 갖는 마이크로-나노 혼성구조를 제작하였다. 소수성 고분자로는 PFPE (perfluoropolyether bisurethane methacrylate)를 사용하였으며 마이크로 단일구조는 PDMS (polydimethylsiloxane) 몰드를 사용하는 스탬핑 방식으로 제작하였다. 다양한 형태로 제작한 PFPE 마이크로 단일구조와 마이크로-나노 혼성구조의 표면 접촉각을 측정하여 표면 미세구조에 따른 소수성의 변화를 관찰하였다. 마이크로 단일구조의 경우 접촉각은 안정적인 값을 보이지 못하였으나 단일 구조에 나노입자를 사용한 식각을 적용해 나노구조가 형성됨에 따라 $150^{\circ}$ 이상의 접촉각을 갖는 초소수성 표면이 매우 높은 재현성으로 용이하게 형성되었다.

다양한 UBM층상의 Sn0Ag0.5Cu 솔더 범프의 고속 전단특성에 미치는 전단속도의 영향 (Effect of Shearing Speed on High Speed Shear Properties of Sn1.0Ag0.5Cu Solder Bump on Various UBM's)

  • 이왕구;정재필
    • 대한금속재료학회지
    • /
    • 제49권3호
    • /
    • pp.237-242
    • /
    • 2011
  • The effect of shearing speed on the shear force and energy of Sn-0Ag-0.5Cu solder ball was investigated. Various UBM (under bump metallurgy)'s on Cu pads were used such as ENEPIG (Electroless Nickel, Electroless Palladium, Immersion Gold; Ni/Pd/Au), ENIG (Electroless Nickel, Immersion Gold; Ni/Au), OSP (Organic Solderability Preservative). To fabricate a shear test specimen, a solder ball, $300{\mu}m$ in diameter, was soldered on a pad of FR4 PCB (printed circuit board) by a reflow soldering machine at $245^{\circ}C$. The solder bump on the PCB was shear tested by changing the shearing speed from 0.01 m/s to 3.0 m/s. As experimental results, the shear force increased with a shearing speed of up to 0.6 m/s for the ENIG and the OSP pads, and up to 0 m/s for the ENEPIG pad. The shear energy increased with a shearing speed up to 0.3 m/s for the ENIG and the OSP pads, and up to 0.6 m/s for the ENEPIG pad. With a high shear speed of over 0 m/s, the ENEPIG showed a higher shear force and energy than those of the ENIG and OSP. The fracture surfaces of the shear tested specimens were analyzed, and the fracture modes were found to have closer relationship with the shear energy than the shear force.

타이타늄의 표면개질에 따른 도재 결합 특성 (THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION)

  • 최택휴;박상원;방몽숙;양홍서;박하옥;임현필;오계정;김현승;이광민;이경구
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.

ONE-STEP 접착제의 상아질 접착에 관한 연구 (A STUDY ON THE DENTIN BONDING OF ONE-STEP BONDING AGENT)

  • 조영곤;박성택;박광수
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.468-476
    • /
    • 1998
  • The purpose of this study was to observe the morphologic change of dentinal surface, adhesion in interface between dentin and bonding agents, and penetration pattern of resin tags into dentinal tubles according to bonding procedure of ONE-STEP universal adhesive system. Ten extracted human molars were mounted in dental stone and sectioned to expose mid-coronal occlusal dentin and again sectioned tooth crown apically. Specimens were randomly assigned to three groups for dentin conditioning with 32% phoshoric acid, two coats of bonding agents after dentin conditioning, and bond of composite resin. The surfaces of dentin were treated with etch ant and applied bonding agent, and bonded composite resin according to the directions of manufacturer. Specimens which were boned composite were sectioned longitudinally for observing interfaces between resin and dentin. Two of specimens which were sectioned longitudinally were immersed in 6 N HCL for 30 seconds and 1% NaOCL for 12 hours to partially demineralize and deproteinize the dentin substrate. Each specimen was mounted on a brass stub, sputter-coated with gold and observed under SEM. The result were as follows : 1. On the dentinal surface which was conditioned with 32% phosphoric acid. the smear layer was completely removed. orifices of dentinal tubules were opened 3-$5{\mu}m$ wide. and dentinal surface was irregular. 2. On the dentinal surface which was applied ONE-STEP. bonding agent. resin particles were observed on the orifices of dentinal tubules and intertubular dentin. 3. There were close adaptation between dentin and resin and were the pattern which composite invaded into dentin. 4. 1-$3{\mu}m$-wide hybrid layer was visible in the interface between dentin and resin. 5. Long and funnel shaped resin tags were observed in demineralized specimens. and the surfaces of tags were rough.

  • PDF

CAD/CAM으로 제작된 세라믹 인레이의 변연 및 내면 적합성 (MARGINAL AND INTERNAL FIT OF CAD/CAM-MANUFACTURED CERAMIC INLAY)

  • 손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.618-629
    • /
    • 1998
  • CAD/CAM-fabricated ceramic restorations nowadays are used as alternatives of amlagam and posterior composite resin restorations, especially in the cases of inlay restorations. But the reported results on marginal and internal fit of CAD/CAM-fabricated ceramic inlay have showed considerable difference. In this study, to evaluate the marginal and internal fit of CEREC2-fabricated ceramic inlay restoration and to compare with the fit of gold inlay and amalgam restoration, standardized Class II MO cavities were prepared in forty extracted caries-free human premolars. The teeth with prepared cavities were divided into 4 groups of ten teeth each. In group 1, CEREC2-fabricated ceramic inlays were treated with Scotchbond Multi-Purpose Plus(SMP plus) and cemented with Scotchbond Resin Cement. In group 2, casted gold inlays were cemented in the same method as in group 1. In group 3, casted gold inlays were cemented with zinc-phosphate cement. And in group 4, the prepared cavities were restored with amalgam. Restored teeth were thermocycled, stored in 1% methylene blue for 24 hours, and sectioned faciolingually and mesiodistally using EXAKT. Sectioned surfaces were observed with stereomicroscope and the gaps were measured at 9 points of mesiodistally sectioned surface and 7 points of faciolingually sectioned surface. The measured data were treated by Kruskal-Wallis one way ANOVA and Student-Newman-Keuls test. 1. The differences among measured gaps at each points were statistically significant for 4 experimental groups (P<0.05). 2. There were statistically significant differences in the measured gaps at each points between group 1 and group 2, group 1 and group 3, group 1 and group 4, group 2 and group 4, and group 3 and group 4 (P<0.05). 3. There were not statistically significant differences in the measured gaps at each points between group 2 and group 3 (P>0.05). 4. In the cases of inlay restorations(group 1, group 2, group 3), the gaps at internal line angle(distopulpal, axiogingival, faciopulpal, linguopulpal line angle) had a tendency to increase. In the cases of amalgam restorations(group 4), the gaps at occlusal margin, gingival margin and axiogingival line angle were greater than those at the other parts of cavities. 5. In CEREC2-fabricated ceramic inlays which were treated with Scotchbond Multi-Purpose Plus and cemented with Scotchbond Resin Cement, the mean gaps were $111{\mu}m$ at cavity margins, $168{\mu}m$ at vertical walls of cavities, $225{\mu}m$ at internal line angles and $123{\mu}m$ at cavity floors.

  • PDF

레이저 간섭계를 이용한 적층 마이크로 외팔보의 고유진동수 측정 (Measurement on the Natural Frequency of a Laminated Cantilever Microbeam using a Laser Interferometer)

  • 김윤영;한봉구
    • 한국전산구조공학회논문집
    • /
    • 제31권1호
    • /
    • pp.17-21
    • /
    • 2018
  • 오늘날까지 적층 마이크로 외팔보의 고유진동수에 대하여 연구가 진행되었다. 마이크로 보는 실리콘 재질로 만들어 지지만, 그것의 상하 표면은 얇은 금 박막층(~30nm)이 증착되어 있다. 초음파 검사를 위해 초음파 테스트 플랫폼을 사용했으며, 시간영역 신호는 광학적으로 측정되었다. 고유진동수는 파형을 고속 Fourier 변환을 통해 정량화하였으며, 결과적으로 고전적인 보 이론과 일치하는 결과를 보여 주었다. 본 연구는 마이크로/나노스케일 재료와 마이크로 구조에 대한 동적평가기법을 제공할 것으로 기대된다.

Measurement of Effective Refractive Index of Nematic Liquid Crystal in Fabry-Perot Etalon

  • Ko, Myeong Ock;Kim, Sung-Jo;Kim, Jong-Hyun;Lee, Bong Wan;Jeon, Min Yong
    • Journal of the Optical Society of Korea
    • /
    • 제19권4호
    • /
    • pp.346-350
    • /
    • 2015
  • We report a measurement of the effective refractive index of a nematic liquid crystal (NLC) inside a Fabry-Perot (FP) etalon according to the applied electric fields. The effective refractive index of the NLC depends on the intensity of the applied electric field. A wavelength-swept laser with a polygon-scanner-based wavelength filter is used as a wide-band optical source to measure the effective refractive index of the NLC. The bandwidth of the optical source is greater than 90 nm around 1300 nm. The fabricated NLC FP etalon consists of glass substrates, gold layers as the electrodes with highly reflective surfaces, polyimide layers as the planar alignment layers, and an LC layer. Furthermore, we measured the Freedericksz transition voltages for three types of NLC FP etalons having thicknesses of $30.6{\mu}m$, $55.4{\mu}m$, and $108.8{\mu}m$. The Freedericksz transition voltages in the three cases are nearly equal. The measured effective refractive indices in the three cases decreased from 1.67 to 1.51 as the applied electric field intensity was increased. Beyond the threshold electric field, the effective refractive indices quickly decreased and eventually saturated at a value of 1.51 for all cases.

Ionic Recognition with Quinone-Derivatized Calixarenes in Solution and at Self-Assembled Monlayers

  • Kim Hasuck;Kang Sun Kil;Chung Taek Dong
    • 전기화학회지
    • /
    • 제3권2호
    • /
    • pp.69-71
    • /
    • 2000
  • 카르복시산과 이황하물 다리를 가지며 산화환원 활성이 있는 칼릭스[4]아렌을 합성하였고 그것이 은과 금 표면 위에 자발적으로 흡착하는 것을 관찰하였다. 칼릭스[4]아렌은 특이한 구조 때문에 수용액에서 알칼리 토금속이온에 선택적인 친화력을 보인다 한편 둥그런 이온 수용체를 전극 위에 고정시켰을 때 금속 이온을 포획하는 것을 전압전류법 및 분광학적인 연구를 통해 확인하였다. 아울러 EDTA와 같은 강한 킬레이트제를 이용하여 이온을 가역적으로 제거할 수 있음을 보였다.