• 제목/요약/키워드: Gold electrodes

검색결과 150건 처리시간 0.033초

Electrochemical Determination of As(III) at Nanoporous Gold Electrodes with Controlled Surface Area

  • Seo, Min Ji;Kastro, Kanido Camerun;Kim, Jongwon
    • 대한화학회지
    • /
    • 제63권1호
    • /
    • pp.45-50
    • /
    • 2019
  • Because arsenic (As) is a chemical substance toxic to humans, there have been extensive investigations on the development of As detection methods. In this study, the electrochemical determination of As on nanoporous gold (NPG) electrodes was investigated using anodic stripping voltammetry. The electrochemical surface area of the NPG electrodes was controlled by changing the reaction times during the anodization of Au for NPG preparation, and its effect on the electrochemical behavior during As detection was examined. The detection efficiency of the NPG electrodes improved as the roughness factor of the NPG electrodes increased up to around 100. A further increase in the surface area of the NPG electrodes resulted in a decrease of the detection efficiency due to high background current levels. The most efficient As detection efficiency was obtained on the NPG electrodes prepared with an anodization time of 50 s. The effects of the detection parameters and of the Cu interference in As detection were investigated and the NPG electrode was compared to flat Au electrodes.

Au와 탄소나노튜브 복합체 전극의 연성 향상 (Enhanced Stretchability of Gold and Carbon Nanotube Composite Electrodes)

  • 우정민;전주희;강지연;이태일;명재민
    • 한국재료학회지
    • /
    • 제21권3호
    • /
    • pp.133-137
    • /
    • 2011
  • Gold have been used as an electrode materials having a good mechanical flexibility as well as electrical conductivity, however the stretchability of the gold on a flexible substrate is poor because of its small elastic modulus. To overcome this mechanical inferiority, the reinforcing gold is necessary for the stretchable electronics. Among the reinforcing materials having a large elastic modulus, carbon nanotube (CNT) is the best candidate due to its good electrical conductivity and nanoscale diameter. Therefore, similarly to ferroconcrete technology, here we demonstrated gold electrodes mechanically reinforced by inserting fabrics of CNTs into their bodies. Flexibility and stretchability of the electrodes were determined for various densities of CNT fabrics. The roles of CNTs in resisting electrical disconnection of gold electrodes from the mechanical stress were confirmed using field emission scanning electron microscope and optical microscope. The best mechanical stability was achieved at a density of CNT fabrics manufactured by 1.5 ml spraying. The concept of the mechanical reinforced metal electrode by CNT is the first trial for the high stretchable conductive materials, and can be applied as electrodes materials in various flexible and stretchable electronic devices such as transistor, diode, sensor and solar cell and so on.

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

An Electrochemical Approach for Fabricating Organic Thin Film Photoelectrodes Consisting of Gold Nanoparticles and Polythiophene

  • Takahashi, Yukina;Umino, Hidehisa;Taura, Sakiko;Yamada, Sunao
    • Rapid Communication in Photoscience
    • /
    • 제2권3호
    • /
    • pp.79-81
    • /
    • 2013
  • A novel method of fabricating polythiophene-gold nanoparticle composite film electrodes for photoelectric conversion is demonstrated. The method includes electrodeposition of gold and electropolymerization of 2,2'-bithiophene onto an indium-tin-oxide (ITO) electrode. First, electrodeposition of gold onto the ITO electrode was carried out with various repetition times of pulsed applied potential (0.25 s at -2.0 V vs. Ag/AgCl) in an aqueous solution of $HAuCl_4$. Significant progress of the number density of deposited gold nanoparticles was confirmed from scanning electron micrographs, from 4 (1 time) to 25% (15 times). Next, electropolymerization of 2,2'-bithiophene onto the above ITO electrode was performed under controlled charge condition (+1.4 V vs. Ag wire, 15 $mC/cm^2$). Structural characterization of as-fabricated films were carried out by spectroscopic and electron micrographic methods. Photocurrent responses from the sample film electrodes were investigated in the presence of electron acceptors (methyl viologen and oxygen). Photocurrent intensities increased with increasing the density of deposited gold nanoparticles up to ~10%, and tended to decrease above it. It suggests that the surplus gold nanoparticles exhibit quenching effects rather than enhancement effects based on localized electric fields induced by surface plasmon resonance of the deposited gold nanoparticles.

Enhanced Electrical Conductivity of Gold Doped Graphene Films by Microwave Treatment

  • Kim, Yoo-Seok;Song, Woo-Seok;Cha, Myoung-Jun;Lee, Su-Il;Cho, Ju-Mi;Kim, Sung-Hwan;Park, Chong-Yun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.188-188
    • /
    • 2012
  • Graphene, with its unique physical and structural properties, has recently become a proving ground for various physical phenomena, and is a promising candidate for a variety of electronic device and flexible display applications. Compared to indium tin oxide (ITO) electrodes, which have a typical sheet resistance of ${\sim}60{\Omega}$/sq and ~85% transmittance in the visible range, the chemical vapor deposition (CVD) synthesized graphene electrodes have a higher transmittance in the visible to IR region and are more robust under bending. Nevertheless, the lowest sheet resistance of the currently available CVD graphene electrodes is higher than that of ITO. In this study, we report a creative strategy, irradiation of microwave at room temperature under vacuum, for obtaining size-homogeneous gold nano-particle doping on graphene. The gold nano-particlization promoted by microwave irradiation was investigated by transmission electron microscopy, electron energy loss spectroscopy elemental mapping. These results clearly revealed that gold nanoparticle with ${\geq}30$ nm in mean size were decorated along the surface of the graphene after microwave irradiation. The fabrication high-performance transparent conducting film with optimized doping condition showed a sheet resistance of ${\geq}100{\Omega}$/sq. at ~90% transmittance. This approach advances the numerous applications of graphene films as transparent conducting electrodes.

  • PDF

Size-homogeneous gold nanoparticle decorated on graphene via MeV electron beam irradiation

  • Kim, Yoo-Seok;Song, Woo-Seok;Jeon, Cheol-Ho;Kim, Sung-Hwan;Park, Chong-Yun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.487-487
    • /
    • 2011
  • Recently graphene has emerged as a fascinating 2D system in condensed-matter physics as well as a new material for the development of nanotechnology. The unusual electronic band structure of graphene allows it to exhibit a strong ambipolar electric field effect with high mobility. These properties lead to the possibility of its application in high-performance transparent conducting films (TCFs). Compared to indium tin oxide (ITO) electrodes, which have a typical sheet resistance of ${\sim}60{\Omega}$/sq and ~85 % transmittance in the visible range (400?900 nm), the CVD-grown graphene electrodes have a higher/flatter transmittance in the visible to IR region and are more robust under bending. Nevertheless, the lowest sheet resistance of the currently available CVD graphene electrodes is higher than that of ITO. Here, we report an ingenious strategy, irradiation of MeV electron beam (e-beam) at room temperature under ambient condition, for obtaining size-homogeneous gold nanoparticle decorated on graphene. The nano-particlization promoted by MeV e-beam irradiation was investigated by transmission electron microscopy, electron energy loss spectroscopy elemental mapping, and energy dispersive X-ray spectroscopy. These results clearly revealed that gold nanoparticle with 10 ~ 15 nm in mean size were decorated along the surface of the graphene after 1.5 MeV-e-beam irradiation. A chemical transformation and charge transfer for the metal gold nanoparticle were systematically explored by X-ray photoelectron spectroscopy and Raman spectroscopy. This approach advances the numerous applications of graphene films as transparent conducting electrodes.

  • PDF

금 전극을 이용한 동물 조직 내 임피던스 측정연구 (A Study on the Measurement of Impedance in Animal Tissue Using Gold Electrodes)

  • 김민수;조영창
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.445-450
    • /
    • 2021
  • 생체임피던스 측정법은 편리성, 저비용 및 저가의 장치를 이용하여 생체정보 획득 및 피부 병 진단 등에 사용 가능한 장치이다. 본 연구에서는 생체 삽입형으로 생체 정보를 획득하기 위해서 동물 생체 모델링을 통한 시뮬레이션 연구와 직접 제작한 건식용 금 전극을 이용하여 생체임피던스를 측정하였다. 동물 조직의 피하부위에 전극을 삽입하여 2 전극법으로 100 uA, 1-100 kHz 주파수를 인가하여 임피던스를 측정하였다. 측정결과 전극의 사이즈를 5 mm전극기준으로 7.5 mm, 10 mm전극과 비교하여 저항을 측정한 결과 5 mm 전극에서 높게 측정됨을 확인할 수 있다. 5 mm전극을 기준으로 7.5 mm 전극은 전체 주파수 범위에서 평균 1.49 %차이를 발견하였고, 10 mm 전극은 2.624 %로 임피던스가 차이남을 확인하였다. 향후, 연구결과는 생체 삽입형 심전도 센서 전극 설계 및 제작 등에 활용가치가 있을 것으로 사료된다.

Microfludic 플랫폼을 이용한 생체 분자의 voltammetric 분석 (Microfluidic platform for voltammetric analysis of biomolecules)

  • ;한다운;;김용상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1686-1687
    • /
    • 2011
  • A microfabricated chip with in-channel electrochemical cell using interdigitated gold electrode was fabricated for sensitive electrochemical analysis. The gold electrodes were fabricated on glass wafer using thermal evaporator and were covered using PDMS mold containing microchannel for analyte and electrolyte. The active area of each electrode was $250\;{\mu}m{\times}200\;{\mu}m$ with a gap of 200 ${\mu}m$ between the electrodes. Microelectrodes results in maximum amplification of signal, since the signal enhancement effect due to cycling of the reduced and oxidized species strongly depends on the inter electrode distance. Analytes such as methylene blue and guanosine were characterized using the fabricated electrodes and their electrochemical characteristics were compared with conventional bulk electrodes. The device so developed shall find use as disposable electrochemical cell for rapid and sensitive analysis of electroactive species.

  • PDF

SAMs of 2-Aminoethanethiol Modified with 3,4-Dihydroxyphenylalanine for the Electrocatalytic Oxidation of NADH on Gold Electrodes

  • Cha, Seong-Keuck
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.786-790
    • /
    • 2004
  • 2-Aminoethanethiol (aet) has been used to make self-assembled monolayer (SAMs) on gold electrodes, which are subsequently modified with 3,4-dihydroxy phenylalanine (dpa). Such modified electrodes having various types of Au/aet-dpa were employed in the electrocatalytic oxidation of NADH. The purpose of this study to characterize the responses of such modified electrodes in terms of the immobilization procedure, pH of the solution and applied potential. The reaction of the surface immobilized dpa with NADH was studied using the rotating disk electrode technique and a value of $2.2{\times}10^4M^{-1}s^{-1}$ was obtained for the second-order rate constant in 0.1 M Tris/$NO_3^-$buffer (pH=8.0). The hydration behavior of the films was characterized by quartz crystal microbalance. When used as a NADH sensor, the Au/aet-dpa electrode exhibited good sensitivity and an excellent correlation (r ${\geq}$ 0.99) for NADH concentration which extended to $3.8{\times}10^{-3}$ M.

Poly(3,4-ethylenedioxythiophene) Electrodes Doped with Anionic Metalloporphyrins

  • 송의환;여인형;백운기
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권11호
    • /
    • pp.1303-1308
    • /
    • 1999
  • Conducting poly(3,4-ethylenedioxythiophene) (PEDT) films with metalloporphyrins incorporated as the counter ions were prepared by electropolymerization of the monomer in the presence of metal-tetra(sulfonatophenyl) porphyrin anions. Cathodic reduction of oxygen on the resulting conducting polymer films was studied. The overpotential for O2 reduction on electrodes with cobalt-porphyrin complex was significantly smaller in acidic solutions than on gold. In basic solutions, the overpotential at low current densities was close to those on platinum and gold. Polymer electrode with Co-complex yielded higher limiting currents than with Fe-complex, although the Co-complex polymer electrode was a poorer electrocatalyst for O2 reduction in the activation range of potential than the Fe counterpart. From the rotating ring-disk electrode experiments, oxygen reduction was shown to proceed through either a 4-electron pathway or a 2-electron pathway. In contrast to the polypyr-role-based electrodes, the PEDT-based metalloporphyrin electrodes were stable with wider potential windows, including the oxygen reduction potential. Their electrocatalytic properties were maintained at temperatures up to 80℃ in KOH solutions.