• 제목/요약/키워드: Gold electrode

검색결과 221건 처리시간 0.028초

Voltammetric Behaviors of Chemically Modified Electrodes Based on Zirconium Phosphonate Film

  • 홍훈기
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권9호
    • /
    • pp.886-891
    • /
    • 1995
  • Electroactive monolayers based on zirconium(Ⅳ) phosphonate film were prepared on gold and tin oxide electrodes by sequential layer-by-layer depostion technique. High transfer coefficient values and surface coverages of surface bound redox molecules were obtained from the electrochemical measurements of heterogeneous electron transfer rates for monolayer modified electrodes. 1,10-Decanediylbis(phosphonic acid) (DBPA) monolayer as insulating barrier was effective in blocking electron transfer. However, these film modified oxide electrode shows voltammetric behavior of diffusion/permeation process taking place at very small exposed area of modified electrode through channels due to structural defects within film when a very fast redox couple such as Ru(NH3)63+ is hired.

침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구 (A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD)

  • 계기성;정재헌;강동완;김병옥;황호길;고영무
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

Electrochemical Characterization of Nanosized Electrode Arrays Prepared from Nanoporous Self-Assembled Monolayers

  • Choi, Shin-Jung;Park, Su-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권5호
    • /
    • pp.699-704
    • /
    • 2002
  • We characterized nanoelectrode arrays prepared from self-assembled monolayers (SAMs) by adsorption from a solution containing thiolated $\beta$-cyclodextrin ($\beta$-CD) and n-alkanethiol on the gold electrode surface, using electrochemical methods. While the framework, the n-hexadecanethiol SAM, effectively blocked electron transfer between the electrode surface and solution-phase redox probe molecules, the $\beta$-CD cavities isolated in the forests of n-hexadecanethiol molecules were shown to act as an ultramicroelectrode array. The shapes of cyclic voltammograms of probe molecules were related to the number densities of $\beta$-CD molecules within the monolayer films. Probe molecules that have the correct combination of physical and chemical characteristics were shown to effectively penetrate the framework through the $\beta$-CD pores and exchange electrons with the electrode surface.

미소전극어레이형 DNA칩을 이용한 유전자다형의 전기화학적 검출 (Electrochemical Detection of Single Nucleotide Polymorphism (SNP) Using Microelectrode Array on a DNA Chip)

  • 최용성;권영수;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.286-292
    • /
    • 2004
  • In this study, an integrated microelectrode array was fabricated on glass slide using microfabrication technology. Probe DNAs consisting of mercaptohexyl moiety at their 5-end were spotted on the gold electrode using micropipette or DNA arrayer utilizing the affinity between gold and sulfur. Cyclic voltammetry in 5mM ferricyanide/ferrocyanide solution at 100 ㎷/s confirmed the immobilization of probe DNA on the gold electrodes. When several DNAs were detected electrochemically, there was a difference between target DNA and control DNA in the anodic peak current values. It was derived from specific binding of Hoechst 33258 to the double stranded DNA due to hybridization of target DNA. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic System.

미소전극형 DNA칩 어레이를 이용한 유전자의 검출 (A Study on Electrical Properties of Dendrimer)

  • 최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1324-1326
    • /
    • 2006
  • In this study, an integrated microelectrode array was fabricated on glass slide using microfabrication technology. Probe DNAs consisting of mercaptohexyl moiety at their 5-end were spotted on the gold electrode using micropipette or DNA arrayer utilizing the affinity between gold and sulfur. Cyclic voltammetry in 5mM ferricyanide/ferrocyanide solution at 100 mV/s confirmed the immobilization of probe DNA on the gold electrodes. When several DNAs were detected electrochemically, there was a difference between target DNA and control DNA in the anodic peak current values. It was derived from specific binding of Hoechst 33258 to the double stranded DNA due to hybridization of target DNA. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic system.

  • PDF

Detecting gold by voltammetric handhold systems

  • Kim, Nack-Joo;Choi, Dal-Woong;Yoo, Hai-Soo;Lee, Kyung;Lee, Chang-Hyun;Ly, Suw-Young;Kim, Tae-Yun
    • 한국응용과학기술학회지
    • /
    • 제31권3호
    • /
    • pp.472-477
    • /
    • 2014
  • A voltammetric investigation of Au assay was conducted at a low cost, using Nafion and DNA immobilized on a graphite Pencil working electrode (NDP) with a black lead counter and reference. The following optimal parameters were found: 0.4 V amplitude, 500 Hz frequency, -0.7 V initial potential, and 0.015 V increment potential. These optimal conditions were also applied to sand obtained from the river site. The aforementioned technique is simpler and less costly compared to the common voltammetry and spectrophotometric methods.

Electrochemical Determination of As(III) at Nanoporous Gold Electrodes with Controlled Surface Area

  • Seo, Min Ji;Kastro, Kanido Camerun;Kim, Jongwon
    • 대한화학회지
    • /
    • 제63권1호
    • /
    • pp.45-50
    • /
    • 2019
  • Because arsenic (As) is a chemical substance toxic to humans, there have been extensive investigations on the development of As detection methods. In this study, the electrochemical determination of As on nanoporous gold (NPG) electrodes was investigated using anodic stripping voltammetry. The electrochemical surface area of the NPG electrodes was controlled by changing the reaction times during the anodization of Au for NPG preparation, and its effect on the electrochemical behavior during As detection was examined. The detection efficiency of the NPG electrodes improved as the roughness factor of the NPG electrodes increased up to around 100. A further increase in the surface area of the NPG electrodes resulted in a decrease of the detection efficiency due to high background current levels. The most efficient As detection efficiency was obtained on the NPG electrodes prepared with an anodization time of 50 s. The effects of the detection parameters and of the Cu interference in As detection were investigated and the NPG electrode was compared to flat Au electrodes.

자가조립 단층 전극에 대한 순환전위법의 특성해석 (Characteristic Analysis of Cyclic Voltammetry on a Self-Assembled Mono-layer Electrode)

  • 조하나;윤도영
    • 전기화학회지
    • /
    • 제16권4호
    • /
    • pp.217-224
    • /
    • 2013
  • 본 연구에서는 금 나노입자로 전착된 전극위에 3-MPA로 개질된 자가조립 단층 전극의 순환전위법의 특성을 조사하였다. 또한 전극 주변에서 전자와 이온의 이동현상을 해석하였다. 반무한 확산모델을 채택하여, 물질전달 지배계에 대하여 지배방정식과 경계조건을 유도하였다. 자가조립단층 전극에 대한 순환전위법의 수치해를 구하기 위하여, 양함수 유한차분법을 적용하여 MATLAB 프로그램을 작성하여 해를 구현하였다. 자가조립으로 개질된 전극에 대한 본 CV 용 프로그램은 3-MPA으로 개질된 금 나노입자 SAM 전극의 순환전위법 실험결과를 잘 설명하고 있음을 확인할 수 있었다.

금 나노입자/폴리(maleic anhydride) 그래프트 탄소나노튜브에 글루코스 옥시다아제 담지를 기반으로 한 글루코스 바이오센서 (A glucose biosensor based on deposition of glucose oxidase onto Au nanoparticles poly(maleic anhydride)-grafted multiwalled carbon nanotube electrode)

  • 박명화;손평수;장주환;최성호
    • 분석과학
    • /
    • 제23권2호
    • /
    • pp.165-171
    • /
    • 2010
  • 글루코스 옥시다아(GOx)제 고정화 바이오센서를 두 가지 방법으로 제조 하였다. 첫 번째 방법은 폴리(maleic anhydride) 그래프트 탄소나노튜브(PMAn-g-MWCNT) 전극에 감마선 조사법으로 제조 된 Au 나노입자를 물리적으로 흡착시킨 후, GOx을 고정화 시켜 바이오센서를 제조한 경우이고, 다른 하나는 PMAn-g-MWCNT 전극에서 Au 이온을 전기화학적으로 환원시켜 Au 나노입자를 코팅 시키고, 그 위에 GOx을 고정화 시켜 바이오센서를 제조 한 경우이두. 제조된 바이오센서에 대해 효율 평가를 수행 하였는데, 물리적 흡착법으로 제조된 전극의 경우 검출 범위는 $30\;{\mu}M\sim100\;{\mu}M$이었으며, 검출한계는 $15\;{\mu}M$이었다. 또한 ascorbic acid와 uric acid에 대한 검출한계는 7.6%이었다. 물리적으로 Au 나노입자가 흡착된 전극의 경우가 글루코스 측정에 매우 우수한 전극임을 확인 하였다.

인쇄공정으로 제조된 저항형 습도센서의 감습특성에 대한 전극패턴의 영향 연구 (The Effect of Electrode Pattern on the Humidity-sensing Properties of the Resistive Humidity Sensor Based on All-printing Process)

  • 안희용;공명선
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.169-176
    • /
    • 2012
  • 저항형 습도센서의 개발을 위하여 스크린 인쇄방법으로 glass epoxy(GE) 기재 위에 핑거의 수와 그 사이의 간격이 다른 여러 가지 바이트형의 금 전극을 제조하였다. 전극의 기본적인 구조는 핑거 수가 3, 4 및 5를 가지며 간격은 각각 310과 460 ${\mu}m$이다. 전극은 처음에 은 나노 페이스트로 전극 패턴을 인쇄하고 연속적으로 Cu, Ni 및 Au를 무전해 도금을 진행하여 제조하였다. 감습성 고분자 전해질은 [2-(methacryloyloxy)ethyl] dimethyl benzyl ammonium chloride(MDBAC)과 methyl methacrylate(MMA)의 공중합체를 사용하였으며 스크린 인쇄 방법으로 Au 전극/GE 기재 위에 인쇄하였다. 이렇게 제조된 습도 센서의 20-95%RH 영역의 상대습도 대 로그 임피던스 그래프에서 좋은 직선성을 보여주었으며 히스테리시스는 1.5%RH 이하 및 75초의 응답 및 회복 속도를 보여주었다. 전극의 구조는 고분자 저항형 습도센서의 감습특성에 큰 영향을 미치며 전해질 고분자와 전극 사이의 활성화 에너지, 온도의존성, 감도, 직선성 및 히스테리시스와 같은 감습특성 등의 차이를 비교하였고 특히 이온의 이동에 관여하는 활성화 에너지 및 온도 의존성에 큰 영향을 미쳤다.