• Title/Summary/Keyword: Glow Discharge

Search Result 260, Processing Time 0.032 seconds

A Study on Air Emission Spectra Observed by Using Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) (Electrothermal-Hollow Cathode Glow Discharge Spectrometry(Et-HCGDS)를 이용하여 살펴본 Air Emission에 관한 연구)

  • Lee, Sang Chun;Shin, Jung-Sook;Kang, Mi-Ra
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.5
    • /
    • pp.399-407
    • /
    • 1995
  • Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) has been constructed in our laboratory for in-situ monitoring of traceble amounts of rare earth elements and actinides. Et-HCGDS is the portable glow discharge system that can perform the trace analysis of elements. The main structural design of Et-HCGDS was based upon the electrothermal heating and glow discharge techniques. More details on Et-HCGDS are available elsewhere. In this study, air was used as a flow gas for the glow discharge system. As a result, the emission spectra of air were collected and the assignment of air emission lines was performed with helps of pure nitrogen and oxygen emission spectra and previously published results. We found that the emission lines of air plasma were mainly due to nitrogen molecules. This paper includes the complete assignments of the air emission lines observed by using Et-HCGDS. Also, this study will be an useful reference for spectrochemical anaysis including air analysis.

  • PDF

Current, flow rate and pressure effects in a Gas-Jet-assisted Glow Discharge source (Gas-Jet-assisted Glow Discharge에서 전류, 가스 흐름 속도, 압력에 따른 영향 연구)

  • Lee, Gaeho;Kim, Dongsoo;Kim, Eunhee;Kang, Seongshik;Park, Minchun;Song, Haeran;Kim, Hasuck;Kim, Hyojin
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.483-492
    • /
    • 1994
  • Direct solid analysis of various kinds of metal samples has been conducted by glow discharge. In this laboratory, the gas-jet assisted glow discharge(GJGD) device has been developed and characterized. The effect of changes in applied current, cell pressure and flow rate on atomic emission signals obtained from a jet-assisted cathodic sputtering was investigate. The emission intensities of Cu, Zn, and Ar were measured. They were increased with the current. But the intensities were decreased by increasing the flow rate of argon due to the diffusion and transportation of particles into plasma. By increasing the pressure of the cell, the intensities were greatly decreased because of enhancement of redeposition onto the surface of the sample.

  • PDF

Direct Anlysis of Impurities in Solides with Glow Discharge Mass Spectrometry

  • Ki Beom Lee;Dae Won Moon;Kwang Woo Lee
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.6
    • /
    • pp.524-529
    • /
    • 1989
  • A glow discharge mass spectrometric(GDMS) analytical method was developed for direct analysis of impurities in solids. Ions extracted from a glow discharge ion source with a sample as a cathode were analyzed by a quadrupole mass filter. Ion extractions were carried out through differentially-pumped orifices biased to positive and negative potentials. Operating parameters of the glow discharge source such as discharge current, orifice-to-cathode distance, energy analyzer setting and bias voltages have been optimized. The developed GDMS was applied to the analysis of KSS copper-base alloy standards certified by Korea Standards Research Institute(KSRI). In the analysis, the reproducibility and the detection limits were estimated to be about 2.5% RSD, and in the low ppm range, respectively.

Study on High Degree of Efficiency Chemical Reactor for Air Purification Using the Glow Discharge (글로우 방전을 이용한 고효율 공기 정화용 화학 반응기의 특성관찰에 관한 연구)

  • Kim, Gi-Ho;Bu, Min-Ho;Lee, Sang-Cheon
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.14-22
    • /
    • 2006
  • the basic model of chemical reactor using glow discharge, we used cathode discharge cell with vacant cavity in the middle. Currently glow discharge is widely studied as a radiation source or atomization device in atomic spectroscopy and remarkable technological achievements are made through the graft with other analysis devices such as microanalysis and steel analysis.1 Additionally, as the characteristics of basic glow discharge and radiation have been reviewed many times, those results could be used in this experiment.2-3 In 1993, an article regarding the treatment of poisonous gas in the air using low temperature plasma was published. According to this article, if DC Glow Discharge is used under continuous atmospheric flow, poisonous gases such as SO2 and NO can be removed.4 Based on those findings, we designed highly efficient reactor where stable air plasma is composed and all air flow pass the negative glow area passing through the tube. It was observed that the cathode tube type glow discharge developed in this study would be economical, easy to use and could be used as radiation source as well.

Effect of Discharge Gas on the Electrical Characteristics of the Glow Discharge Plasma for the Gas Chromatographic Detector (글로우방전 가스크로마토그라프 검출기에서 방전가스의 영향)

  • 박현미;강종성;김효진
    • YAKHAK HOEJI
    • /
    • v.39 no.5
    • /
    • pp.480-486
    • /
    • 1995
  • The change in discharge current of a glow discharge has been shown the potential sensitive detector for gas chromatography. To investigate the effect of carrier gas on the electrical characteristics of the discharge and the peak response, the discharge pressure, gas flow rate, and discharge gap have been studied. The discharge gas included the Ar, He, and N$_{2}$. The gas flow rate has been found one of the important parameters to affect both the electrical characteristics and the peak response.

  • PDF

Development of Analytical Techniques for Human Serum and Urine by Using Glow Discharge (글로우 방전을 이용한 혈청과 뇨의 분석기술 개발)

  • Lee, Sang Chun;Choi, Kyung-Soo;Son, Eun-Ho;Sim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.167-173
    • /
    • 1998
  • An electrothermal vaporization-hollow cathode glow discharge-atomic emission spectrometer(ETV-HCGD-AES) has been developed for detecting heavy metals in human serum and urine samples. Fisrt of all, we designed a glow discharge cell for atomic emission spectrometry and its analytical performance was studied with the standard reference materials(SRMs) purchased from the NIST. Practically, the ETV-HCGD-AES demonstrated better instrumental sensitivity and selectivity for detecting Hg and Pb in the SRMs, serum and urine, than ICP-OES since the ETV-HCGD-AES was not required the complicate sample digestion procedure, which improved sample transportation efficiency.

  • PDF

Glow discharge cleaning 법에 의한 stainless steel의 outgassing rate 감소

  • 임종연;이상균;서인용;최상철;홍승수;신용현;정광화
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.40-40
    • /
    • 1999
  • 가속기나 토카막과 같은 거대한 진공 장치의 용기 내벽을 청정화 하기 위해서는 용기 전체의 열처리(굽기, Baking)와 글로우 방전(Glow discharge) 법을 병행하여 사용한다. Baking은 일반 기체(N2, O2, 그리고 CO2)와 물(H2O)의 탈착에 효과적이고, Glow discharge cleaning은 탄소(Carbon-based)와 산소(Oxygen-based) 화합물의 탈착에 효과적이다. 특히 Glow discharge cleaning의 경우에는 전극의 모양, 진공 용기의 재질과 모양, 전극간의 거리, 사용되는 반응 기체의 압력 등에 따라 그 효과에 큰 차이가 있으므로 다각적인 연구가 필요하다. 본 연구에서는 그림 1과 같이 시험용 스테인레스(AISI 304와 AISI 316LN) 진공 용기를 설치하고, 시험 용기의 한쪽은 배기 용기와 oriffice로, 다른 편은 불순물의 정성.정량 분석을 위해 RGA(Residual gas analyser) 용기와 oriffice로 연결하였다. 전체 시스템 중에서 배기 부분과 분석 부분은 15$0^{\circ}C$에서 24시간 가열하여 전체의 기저 진공도를 1$\times$10-8Torr로 하였다. 기저 진공도의 용기에 고순도의 반응기체 (He, Ar, Ar+He, Ar+H2, Ar+N2 등)를 주입한후, DC 전압(0.8~1.5kV)을 변화하며 글로우 방전의 최적조건을 찾았다. 방전 동안 시험용 용기에서 방출되는 반응 기체 이외의 기체를 RGA로 측정하였고 외부에 Thermocouple을 여러곳에 장착하여 온도 변화를 측정하였다. 이상의 결과로부터 진공 용기 표면적으로부터의 불순물 탈착(desorption)과 불순물 분석, 플라즈마와 내벽의 상호작용등에 대한 결론을 얻을 수 있었다. 또한 Baking과 Glow discharge cleaning을 동시에 수행하여 Baking 온도의 낮춤에 따른 영향 평가도 수행하였다.

  • PDF

Technical tendency of electric field measurements in glow discharge plasmas using laser spectroscopy (레이저를 이용한 방전 플라즈마중의 전계측정 기술 동향)

  • Choi, Y.W.;Bowden, M.;Muraoka, K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1663-1665
    • /
    • 1997
  • Direct measurements of electric fields in a glow discharge are difficult because the measurement method should be sensitive to the electric field and non-intrusive. Laser spectroscopy is very suitable in that it is non-intrusive and allow in-situ measurements to be made. In this report, the measurement techniques of electric fields in glow discharge using laser spectroscopy were described.

  • PDF

Effect of Secondary Electron Emission on the Glow Discharges with Different Electrode Gaps (서로 다른 전극간격에서 이차전자 방출이 글로우 방전에 미치는 영향에 관한 연구)

  • Seo, Jeong-Hyun;Kang, Kyung-Doo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.777-782
    • /
    • 2009
  • In this paper, the effect of the secondary electron emission coefficient of Xe ion on glow discharge was examined by ID numerical simulation. The simulation was performed for two distinct structures, short and long gaps. The features of the glow discharges in the both structures, firing and sustain voltages, luminance, and efficiency, were analyzed at various secondary electron emission coefficient of Xe ion.

Study for Conductive and Non-conductive Multi-layers Depth Profiling Analysis of Radio Frequency Gas-jet Boosted Glow Discharge Spectrometry (Modified Gas-jet Boosted Radio-frequency Glow Discharge 셀의 개발 및 최적화에 관한 연구)

  • Cho, Won Bo;Borden, Stuart;Jeong, Jong Pil;Kang, Won Kyu;Kim, Kyu Whan;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • The new system using a glow discharge atomic emission spectrometer for the direct analysis of solid samples has been developed and characterized. The system was consisted of new glow discharge cell improved previous gas-jet boosted nozzle and radio-frequency power supply. In the case of previous type glow discharge chamber, it had been fitted trace analysis of low alloy steel with low discharge power, because it was to decrease redeposition and increase sample weight loss. But it had a problem that plasma becomes unstale due to increased sample weight loss and redeposition resulting from the high discharge power. Because of being problem of previous glow discharge, it is impossible to analyze using high power. The modified gas-jet boosted glow discharge to solve this problem would improve to be less sample loss rate of modified nozzle than sample loss rate of previous nozzle on the equal discharge condition, and improve to increase stability of plasma. The effect of discharge parameters such as discharge pressure, gas flow rate and power on the sample loss rate, emission intensity has been studied to find optimum discharge conditions. The calibration curves of Fe were obtained with 3 low-alloy samples.