• Title/Summary/Keyword: Global radiation

Search Result 418, Processing Time 0.02 seconds

Study of the solar radiation and economic evaluation for the expected site of solar power plant on the waterworks site (수도사업장 태양광개발 예정지에 대한 일사량 및 경제성 평가에 관한 연구)

  • Choi, Hyeong-Cheol;Lee, Nam-Hyeong;Chang, Jeong-Ho;Na, Hye-Ran
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.139-142
    • /
    • 2009
  • The worldwide energy market is enlarging rapidly according to current issues like globalization, deregulation, global warming and strengthening for environmental regulation as well as the energy technology is developing speedily by the add of information and communication techniques. In spite of these advanced techniques in the field of the renewable energy, solar power depends on the governmental aid largely in comparison with other renewable energy sources because of the high initial investment cost. Therefore it is important to investigate scrupulously for the expected erection site of solar power plant from the planning stage. This paper shows actual measurement data of solar radiation of scheduled solar power locations in the waterworks site with consideration of waterworks facilities and regional specialties and presents the data which was analyzed comparably with the radiation data of adjacent locations served by national authorities. In addition, these data were analyzed using RETScreen and used for making decision on the business validity.

  • PDF

PREVENTION OF CIGARETTE SMOKE INDUCED LUNG CANCER BY LOW LET IONIZING RADIATION

  • Sanders, Charles L.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.539-550
    • /
    • 2008
  • Lung cancer is the most prevalent global cancer, ${\sim}90%$ of which is caused by cigarette smoking. The LNT hypothesis has been inappropriately applied to estimate lung cancer risk due to ionizing radiation. A threshold of ${\sim}1\;Gy$ for lung cancer has been observed in never smokers. Lung cancer risk among nuclear workers, radiologists and diagnostically exposed patients was typically reduced by ${\sim}40%$ following exposure to <100 mSv low LET radiation. The consistency and magnitude of reduced lung cancer in nuclear workers and occurrence of reduced lung cancer in exposed non-worker populations could not be explained by the HWE. Ecologic studies of indoor radon showed highly significant reductions in lung cancer risk. A similar reduction in lung cancer was seen in a recent well designed case-control study of indoor radon, indicating that exposure to radon at the EPA action level is associated with a decrease of ${\sim}60%$ in lung cancer. A cumulative whole-body dose of ${\sim}1\;Gy$ gamma rays is associated with a marked decrease in smoking-induced lung cancer in plutonium workers. Low dose, low LET radiation appears to increase apoptosis mediated removal of $\alpha$-particle and cigarette smoke transformed pulmonary cells before they can develop into lung cancer.

A Study on the Photovoltaic Module Layout Considering the Azimuth and Inclination in Region (방위각 및 경사각을 고려한 지역별 태양광 모듈 배치안 검토)

  • Park, Sung-Hyun;Seo, Jang-Hoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.461-466
    • /
    • 2012
  • Recently, building energy systems with solar collector and solar module have increased to improve energy problem, a heat island, a global warming and carbon dioxide emissions. In this study, value of solar radiation in areas was analyzed using TRNSYS simulation, and the optimum tilt and orientation angle for installing a photovoltaic module was examined. Average values of the weather data in the past twenty years in areas were used as input data. The results show that the tilt angle of a photovoltaic module for gaining the annual maximum solar radiation varies in different localities, and values of the annual solar radiation gained by using the variable photovoltaic module increased by 2.5 percent as compared with that gained by using the fixed photovoltaic module. When fixed photovoltaic module is installed, it should be examined the tilt and orientation angle for installing a photovoltaic module was examined.

Application of Carbon Materials for the Development of Medical Devices (의료기기의 발전을 위한 탄소소재의 활용)

  • Yeong-Gon Kwak
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.23-28
    • /
    • 2023
  • Carbon materials are widely used in many areas of our lives. A fiber having a carbon content of 90% or more obtained by heating an organic fiber precursor is referred to as a "carbon fiber". Carbon fibers are currently used in the medical market to manufacture radiation transmission device parts, artificial joints, and medical aids, as many developments have been made to utilize carbon fibers' characteristics such as light weight, radiation permeability, biocompatibility, high strength, high heat resistance, thermal conductivity, and electrical conductivity. In order to maintain body temperature and increase immunity in long-lasting nuclear medical examination and treatment through the idea of convergence of carbon materials and radiation technology, the quality of medical services can be improved by utilizing carbon materials. We should be aware of the domestic carbon-based medical device industry and make efforts to contribute to the development of medical devices. As a radiation expert, we should try to use our skills and experience to find items that can be fused with medical devices to develop various nuclear medical examination fields and radiographic examination fields that can be widely applied. We should actively engage in future technology development and carbon material research to strengthen the global competitiveness of the domestic medical device industry and improve the quality of medical services.

  • PDF

Calibration of TEPC for CubeSat Experiment to Measure Space Radiation

  • Nam, Uk-Won;Park, Won-Kee;Lee, Jaejin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Kim, Sunghwan;Jin, Ho;Lee, Seongwhan;Kim, Jungho;Kitamura, Hisashi;Uchihori, Yukio
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.2
    • /
    • pp.145-149
    • /
    • 2015
  • A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation. In order to test the performance of the TEPC, we have performed heavy ion beam experiments with the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. In space, human cells can be exposed to complex radiation sources, such as X-ray, Gamma ray, energetic electrons, protons, neutrons and heavy charged particles in a huge range of energies. These generate much a larger range of Linear Energy Transfer (LET) than on the ground and cause unexpected effects on human cells. In order to measure a large range of LET, from 0.3 to $1,000keV/{\mu}m$, we developed a compact TEPC which measures ionized particles produced by collisions between radiation sources and tissue equivalent materials in the detector. By measuring LET spectra, we can easily derive the equivalent dose from the complicated space radiation field. In this HIMAC experiment, we successfully obtained the linearity response for the TEPC with Fe 500 MeV/u and C 290 MeV/u beams and demonstrated the performance of the active radiation detector.

Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.169-174
    • /
    • 2016
  • The aim of this study is to investigate the delivery accuracy of intensity-modulated radiation therapy (IMRT) plans in the two-headed mode of the ViewRay$^{TM}$ system in comparison with that of the normal operation treatment plan of the machine. For this study, a total of eight IMRT plans and corresponding verification plans were generated (four head and neck, two liver, and two prostate IMRT plans). The delivered dose distributions were measured using ArcCHECK$^{TM}$ with the insertion of an ionization chamber. We measured the delivered dose distributions in three-headed mode (normal operation of the machine), two-headed mode with head 1 disabled, two-headed mode with head 2 disabled, and two-headed mode with head 3 disabled. Therefore, a total of four measurements were performed for each IMRT plan. The global gamma passing rates (3%/3 mm) in three-headed mode, head 1 disabled, head 2 disabled, and head 3 disabled were $99.9{\pm}0.1%$, $99.8{\pm}0.3%$, $99.6{\pm}0.7%$, and $99.7{\pm}0.4%$, respectively. The difference in the gamma passing rates of the three- and two-headed modes was insignificant. With 2%/2 mm, the rates were $96.6{\pm}3.6%$, $97.2{\pm}3.5%$, $95.7{\pm}6.2%$, and $95.5{\pm}4.3%$, respectively. Between three-headed mode and head 3 disabled, a statistically significant difference was observed with a p-value of 0.02; however, the difference was minimal (1.1%). The chamber readings showed differences of approximately 1% between three- and two-headed modes, which were minimal. Therefore, the treatment plan delivery in the two-headed mode of the ViewRay$^{TM}$ system seems accurate and robust.

Temperature Correction of Solar Radiation on Clear Sky Using by Modified Pyranometer (특수일사계를 이용한 맑은 날 일사량의 온도 보정)

  • Zo, Il-Sung;Jeong, Myeong-Jae;Lee, Kyu-Tae;Jee, Joon-Bum;Kim, Bu-Yo
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.9-19
    • /
    • 2015
  • Pyranometer have many uncertainty factors (sensitivity function, thermal offset, other spectral effect, geometric, environment, and equipment etc.) than pyrheliometer. The solution for most of the uncertainty factors have been researched, but the problem for thermal offset is being continued research so far. Under the clear sky, due to the thermal offset of pyranometer, the diffuse and global radiation have been negative value for the nighttime and lower value for the daytime, respectively. In order to understand the uncertainty of the thermal offset effect, solar radiation are observed and analyzed using Ji and Tsay method and data from modified pyranometer. As a result of performing temperature correction using the modified pyranometer, the slope (dome factor; k) and intercept ($r_0$) from a linear regression method are 0.064 and $3.457g{\cdot}m^{-2}{\cdot}k^{-1}$, respectively. And the solar radiation is decreased significantly due to the effect of thermal offset during nighttime. The solar radiation from modified pyranometer increased approximately 8% higher than its observed by general pyranometer during daytime. By the way, these results did not generalize because its result is for only single case in clear sky. Accordingly, it is to required for accurate results obtained by the various cases (clear, cloudy and rainy) with longterm observations.

Study on the Improvement of the Radiation Work Field Classification System in Republic of Korea (국내 방사선종사자 피폭 분류체계 개선에 관한 연구)

  • Su-Hui Park;Ji-Young Han;Yong-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.267-275
    • /
    • 2023
  • Occupational exposure records are subject of global interest, and analysis of radiation workers in work categories is being conducted. In Rep. of Korea, according to relevant ministries, the MOHW(Ministry of Health and Welfare), the MAFRA(Ministry of Agriculture, Food and Rural Affairs), and the NSSC(Nuclear Safety and Security Commission) collect and analyze records of occupational exposure by dividing them into 11 work categories. However, this classification system lacks consistency with the systems of major countries, including the UNSCEAR(United Nations Scientific Committee on the Effects of Atomic Radiation). The domestic radiation work field classification system does not have clear classification criteria and does not reflect the characteristics of the radiation work field. Through the analysis of the classification system of the UNSCEAR, we suggested the five main categories(nuclear cycle, medical, industrial, others(education/research, military/public) field and several sub-categories according to each radiation work field.

A Strategy for Environmental Improvement and Internationalization of the IEODO Ocean Research Station's Radiation Observatory (이어도 종합해양과학기지의 복사관측소 환경 개선 및 국제화 추진 전략)

  • LEE, SANG-HO;Zo, Il-SUNG;LEE, KYU-TAE;KIM, BU-YO;JUNG, HYUN-SEOK;RIM, SE-HUN;BYUN, DO-SEONG;LEE, JU-YEONG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.3
    • /
    • pp.118-134
    • /
    • 2017
  • The radiation observation data will be used importantly in research field such as climatology, weather, architecture, agro-livestock and marine science. The Ieodo Ocean Research Station (IORS) is regarded as an ideal observatory because its location can minimize the solar radiation reflection from the surrounding background and also the data produced here can serve as a reference data for radiation observation. This station has the potential to emerge as a significant observatory and join a global radiation observation group such as the Baseline Surface Radiation Network (BSRN), if the surrounding of observatory is improved and be equipped with the essential radiation measuring instruments (pyaranometer and pyrheliometer). IORS has observed the solar radiation using a pyranometer since November 2004 and the data from January 1, 2005 to December 31, 2015 were analyzed in this study. During the period of this study, the daily mean solar radiation observed from IORS decreased to $-3.80W/m^2/year$ due to the variation of the sensor response in addition to the natural environment. Since the yellow sand and fine dust from China are of great interest to scientists around the world, it is necessary to establish a basis of global joint response through the radiation data obtained at the Ieodo as well as at Sinan Gageocho and Ongjin Socheongcho Ocean Research Station. So it is an urgent need to improve the observatory surrounding and the accuracy of the observed data.

Multi-Dimensional Effects on a tow Strain Rate Flame Extinction Under Microgravity Environment (미소 중력장에 있는 저신장율 화염소화에 미치는 다차원 효과)

  • Oh Chang Bo;Kim Jeong Soo;Hamins Anthony;Park Jeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.988-996
    • /
    • 2005
  • Flame structure and extinction mechanism of counterflow methane/air non-premixed flame diluted with nitrogen are studied by NASA 2.2 s drop tower experiments and two-dimensional numerical simulations with finite rate chemistry and transport properties. Extinction mechanism at low strain rate is examined through the comparison among results of microgravity experiment, 1D and 2D simulations with a finite burner diameter. A two-dimensional simulation in counterflow flame especially with a finite burner diameter is shown to be very important in explaining the importance of multidimensional effects and lateral heat loss in flame extinction, effects that cannot be understood using a one-dimensional flamelet model. Extinction mechanism at low strain rate is quite different from that at high strain rate. Low strain rate flame is extinguished initially at the outer flame edge, the flame shrinks inward, and finally is extinguished at the center. It is clarified from the overall fractional contribution by each term in energy equation to heat release rate that the contribution of radiation fraction with 1D and 2D simulations does not change so much and the overall fractional contribution is decisively attributed to radial conduction ('lateral heat loss'). The experiments by Maruta et at. can be only completely understood if multi-dimensional heat loss effects are considered. It is, as a result, verified that the turning point, which is caused only by pure radiation heat loss, has to be shifted towards much lower global strain rate in microgravity flame.