Use of Portable Global Positioning System (GPS) Devices in Exposure Analysis for Time-location Measurement

  • Lee, Ki-Young;Kim, Joung-Yoon;Putti, Kiran;Bennett, Deborah H.;Cassady, Diana;Hertz-Picciotto, Irva
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.461-467
    • /
    • 2009
  • Exposure analysis is a critical component of determining the health impact of pollutants. Global positioning systems (GPS) could be useful in developing time-location information for use in exposure analysis. This study compares four low cost GPS receivers with data logging capability (Garmin 60, Garmin Forerunner 201, GeoStats GeoLogger and Skytrx minitracker MT4100) in terms of accuracy, precision, and ease of use. The accuracy of the devices was determined at two known National Geodetic Survey points. The coordinates logged by the devices were compared when the devices were carried while walking and driving. The Garmin 60 showed better accuracy and precision than the GeoLogger when they were placed at the geodetic points. The Forerunner and Skytrx did not record when they were kept stationary. When the subject wore the devices while walking, the location of the devices differed by about 8 m on average between any two device combinations involving the four devices. The distance between the coordinates logged by the devices decreased when the devices were carried with their antennas facing the sky. All the devices showed similar routes when they were used in a car. All the devices except the Forerunner had satisfactory signal reception when they were worn and when they were carried in the car. The GeoLogger is less comfortable for the subject because of specific wearing requirements. This evaluation found that the Garmin 60 and the Skytrx may be useful in personal exposure analysis studies to record time-location data.

Projection of climate change effects on the potential distribution of Abeliophyllum distichum in Korea (기후변화에 따른 우리나라 미선나무의 분포변화 예측)

  • Lee, Sang-Hyuk;Choi, Jae-Yong;Lee, You-Mi
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.219-225
    • /
    • 2011
  • Changes in biota, species distribution range shift and catastrophic climate influence due to recent global warming have been observed during the last century. Since global warming affects various sectors, such as agriculture and vegetation, it is important to predict more accurate impact of future climate change. The purpose of this study is to examine the observed distribution of Abeliophyllum distichum in the Korean peninsula. For this purpose, two period (present and future) climate data were used. Mean data between 1950 and 2000, were used as the present value and the year 2050 and 2080 data from A1B senario in IPCC SRES were used for the future value. Potential habitation is analyzed by MaxEnt(Maximum Entropy model), and Abeliophyllum distichum's coordinates data were used as a dependent variable and independent variables are composed of environmental data such as BioClim, altitude, aspect and slope. The result of six types GCM mean calculation, the potential habitability decreased by 40-60% of the average existing distribution. The methodogies and results of this research can be applicable to the climate changing adaptation stratiegies for the biodiversity conservation.

Coordinates Determination of tow Level Control Point by Aerial Triangulation (사진기준점측량을 이용한 저등급 기준점의 좌표결정)

  • 최재화;이석배;최윤수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.6 no.2
    • /
    • pp.34-41
    • /
    • 1988
  • Nowadays the considerable improvements, not only in photogrammetric equipment but also in adjustment methods have led to a high accuracy of Aerial Triangulation and reach the step to obtain A.T. technique that uses Global Position System without ground control survery. The enterance of analytical plotter have made considerable development both in accuracy and in efficiency and improved working environment of A.T. by the combination of On-Line Analytical Plotting System. In this paper, in A.T., with using of analytical polotter, aims to improve the acccuracy in coordinates determination of low level control point. The result shows that in case of A.T. with analytical plotter AVIOLYT BC2, the accuracy of control points improves to 7% in planimetry and to 40% in height compared to A.T. with precision plotter Autograph A-8.

  • PDF

The Comparision of Accuracy for GCPs by Maps and GPS in the Purpose of Geometric Correction of Satellite Images (인공위성 영상 지형보정을 위한 GCP 획득에 있어서 지도와 GPS의 정확도 비교)

  • 강인준;최철웅;곽재하
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.1
    • /
    • pp.85-94
    • /
    • 1995
  • Remote Sensing plays an Important role when we gather and extract many informations about development of the land, circumstances of urbans, land use, surveying resource and marine, geological survey, classification of trees, and condition of trees. For geometric collection to improve the accuracy of positioning with data in the processing of projection treatment by remote sensing. Authors have compared two methods by maps and GPS. Thereafter authors study exact transmation of coordinates in the projection of satellite. Authors have tried to gain improvability of difficulties and problems in the real topography, and Authors consider the coordinates system about global superposition by satellite image.

  • PDF

Geomagnetism measured in DZN (Daejeon) Geomagnetic Observatory and its time-variation (대전지자기관측소에서 측정된 지자기 값과 시간에 따른 변화)

  • Lim, Mu-Taek;Park, Yeong-Sue;Rim, Hyeong-Rae;Koo, Sung-Bon;Lee, Young-Cheol;Na, Jae-Shin
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.353-360
    • /
    • 2007
  • KIGAM has installed a FLARE+ continuous geomagnetic observation system in 1998 in Daejeon of which the IAGA identification code is DZN. The coordinates of the absolute measurement plinth precisely determined by the PDGPS(Post-Processing Differential Global Positioning System) is (127-21-37.19E, 36-22-43.96N, 45.93 m) in WGS84 for the horizontal and from the geoid surface for the vertical. Periodically we have conducted the absolute geomagnetic measurement on the plinth above. We have processed the continuous time-variation 3-axis geomagnetic data measured on arbitrary sensors' coordinates in the observatory and absolute geomagnetic data together to get as the results the time-variation H(orizontal), D(eclination), Z(vertical down), F(scalar calculated from 3 components) and P(Proton Precession Magnetometer Data). We have compared our own data with those calculated from the 10th generation IGRF(International Geomagnetic Reference Field). All the measured data in the DZN Observatory can be acquired through the website http://geomag.kigam.re.kr.

  • PDF

Blunder Detection by Matching Strength Measurement in Digital Photogrammetry (수치 사진측량에 있어서 정합 강도 측정에 의한 불량 정합점 제거에 관한 연구)

  • 정명훈;윤홍식;위광재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.191-198
    • /
    • 2000
  • Digital photogrammetry in the implementation of GIS database plays an important role, with the demand for rapid data acquisition and quick updating. Here image matching represents a fundamental task of digital photogrammetry. No image matching algorithm provides a solution as complete as the one given by human vision which is reinforced by knowledge and intelligence capabilities. In this paper, if object space is smooth, we check the global similarity between a possible corresponding point pair and its neighbouring possible corresponding point pairs, detecting blunders; We define matching strength measurement. Besides this, we compute three-dimension coordinates of matching points by bundle adjustment method. Results of the test reveal that the proposed method can eliminate the incorrectly matched pairs efficiently and the accuracy of three-dimension coordinates of matching points come within an allowable error.

  • PDF

An Experimental Study on Assessing Precision and Accuracy of Low-cost UAV-based Photogrammetry (저가형 UAV 사진측량의 정밀도 및 정확도 분석 실험에 관한 연구)

  • Yun, Seonghyeon;Lee, Hungkyu;Choi, Woonggyu;Jeong, Woochul;Jo, Eonjeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.3
    • /
    • pp.207-215
    • /
    • 2022
  • This research has been focused on accessing precision and accuracy of UAV (Unmanned Aerial Vehicle)-derived 3-D surveying coordinates. To this end, a highly precise and accurate testing control network had been established by GNSS (Global Navigation Satellite Systems) campaign and its network adjustment. The coordinates of the ground control points and the check points were estimated within 1cm accuracy for 95% of the confidence level. FC330 camera mounted on DJI Phantom 4 repeatedly took aerial photos of an experimental area seven times, and then processed them by two widely used software packages. To evaluate the precision and accuracy of the aerial surveys, 3-D coordinates of the ten check points which automatically extracted by software were compared with GNSS solutions. For the 95% confidence level, the standard deviation of two software's result is within 1cm, 2cm, and 4cm for the north-south, east-west, and height direction, and RMSE (Root Mean Square Error) is within 9cm and 8cm for the horizontal, vertical component, respectively. The interest is that the standard deviation is much smaller than RMSE. The F-ratio test was performed to confirm the statistical difference between the two software processing results. For the standard deviation and RMSE of most positional components, exception of RMSE of the height, the null hypothesis of the one-tailed tests was rejected. It indicates that the result of UAV photogrammetry can be different statistically based on the processing software.

Effective Global Placement Technique Using Quadratic Programming (Quadratic Programming을 이용한 효과적인 광역배치 기법)

  • Kim Dong-Hyun;Hur Sung-Woo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.6 s.348
    • /
    • pp.23-29
    • /
    • 2006
  • In this paper, we propose an effective global placement technique using quadratic programming(QP). In order to resolve cell congestion problem which is a drawback of QP based placement techniques, additional force and grid pre-warping technique are used. We devised a new density function for evaluating proper additional force which depends on density. Grid pre-warping technique relocates cells over entire area according to the relative ordering between coordinates of cells. Using the additional force obtained by the new density function and applying the pre-warping technique iteratively we obtained a well-distributed global placement. Mongrel which is a middle-down methodology based placer takes such a good global placement as an initial placement and produces a final detailed placement. Experimental results show that proposed technique outperforms the FM algorithm based global placement and are comparable with the well-known leading placers, FengShui, Dragon.

TLS (Total Least-Squares) within Gauss-Helmert Model: 3D Planar Fitting and Helmert Transformation of Geodetic Reference Frames (가우스-헬머트 모델 전최소제곱: 평면방정식과 측지좌표계 변환)

  • Bae, Tae-Suk;Hong, Chang-Ki;Lim, Soo-Hyeon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.315-324
    • /
    • 2022
  • The conventional LESS (LEast-Squares Solution) is calculated under the assumption that there is no errors in independent variables. However, the coordinates of a point, either from traditional ground surveying such as slant distances, horizontal and/or vertical angles, or GNSS (Global Navigation Satellite System) positioning, cannot be determined independently (and the components are correlated each other). Therefore, the TLS (Total Least Squares) adjustment should be applied for all applications related to the coordinates. Many approaches were suggested in order to solve this problem, resulting in equivalent solutions except some restrictions. In this study, we calculated the normal vector of the 3D plane determined by the trace of the VLBI targets based on TLS within GHM (Gauss-Helmert Model). Another numerical test was conducted for the estimation of the Helmert transformation parameters. Since the errors in the horizontal components are very small compared to the radius of the circle, the final estimates are almost identical. However, the estimated variance components are significantly reduced as well as show a different characteristic depending on the target location. The Helmert transformation parameters are estimated more precisely compared to the conventional LESS case. Furthermore, the residuals can be predicted on both reference frames with much smaller magnitude (in absolute sense).

Implementation of Precise Drone Positioning System using Differential Global Positioning System (차등 위성항법 보정을 이용한 정밀 드론 위치추적 시스템 구현)

  • Chung, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.14-19
    • /
    • 2020
  • This paper proposes a precise drone-positioning technique using a differential global positioning system (DGPS). The proposed system consists of a reference station for error correction data production, and a mobile station (a drone), which is the target for real-time positioning. The precise coordinates of the reference station were acquired by post-processing of received satellite data together with the reference station location data provided by government infrastructure. For the system's implementation, low-cost commercial GPS receivers were used. Furthermore, a Zigbee transmitter/receiver pair was used to wirelessly send control signals and error correction data, making the whole system affordable for personal use. To validate the system, a drone-tracking experiment was conducted. The results show that the average real-time position error is less than 0.8 m.