• Title/Summary/Keyword: Glass-to-Glass Delay

Search Result 37, Processing Time 0.024 seconds

Rotational Drive-Versus-Quality and Video Compression-Versus-Delay Analysis for Multi-Channel Video Streaming System on Ground Combat Vehicles (지상 전투 차량을 위한 다채널 영상 스트리밍 시스템의 회전 구동 대비 품질과 압축 대비 지연 분석)

  • Yun, Jihyeok;Cho, Younggeol;Chang, HyeMin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.31-40
    • /
    • 2021
  • The multi-channel video streaming system is an essential device for future ground combat vehicles. For the system, the application of digital interfaces is required instead of the direct analog method to support selectable multiple channels. However, due to the characteristics of the digital interfaces that require en/decoding and signal conversion, the system should support the ability to adapt to quality and delay requirements depending on how video data is utilized. To support addressed issue, this study designs and emulates the multi-channel compressed-video streaming system of ground combat vehicle's fire control system based on commercial standards. Using the system, this study analyzes the quality of video according to the rotational speed of the acquisition device and Glass-to-Glass (G2G) delay between video acquisition and display devices according to video compression rates. Through these experiments and analysis, this paper presents the design direction of the system having scalability on the latest technology while providing high-quality video data streaming flexibly.

Experimental study on build up characteristic of glass dosimeter of preheat and Non-preheat in low energy according to delay time (저에너지X선 영역에서 유리선량계의 preheat과 Non-preheat과의 시간에 따른 build up 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Ki-Won;Son, Soon-Yong;Lim, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3412-3418
    • /
    • 2013
  • The Purpose of this study was to evaluate by comparing the dose change and build up characteristic according to delay time in 30 days of glass dosimeter processed preheat and non preheat when measuring accumulation dose of radiation by using glass dosimeter over the long haul. For obtaining low dose with 0.1 mGy, 1 mGy and 5 mGy, we employed diagnostic generator AccuRay-650R. We compared the build up characteristic over the long haul by exposuring radiation to 30 glass dosimeters sorted into 10 glass dosimeters per tube voltage and current. In Non preheat glass dosimeter, initial measured dose was inferior to exposed dose but as time goes on, was close to exposed dose steadily. In 72 hour after experiment end, non preheat glass dosimeters were not indicated the difference from preheat glass dosimeters and statistical analysis were meaningful (p>0.05). Initial measured dose for low glass dosimeter processed preheat was close to exposed dose and stable. After 15 days dose was gradually increased. Previous study characteristics of glass dosimeter were with respect to characteristic of glass dosimeter in high dose of high energy area. However, in this study, we make a judgment to measure the dose of glass dosimeter without preheat processing when measuring the accumulation dose of low dose in conclusion.

Portable 4K UHD Broadcasting Device using 5G Mobile Network as a Transmission Channel (5G 이동통신망을 전송채널로 활용하는 휴대형 4K UHD 방송중계 장치)

  • Paik, Junghoon;Kim, Yongsuk
    • Journal of Broadcast Engineering
    • /
    • v.25 no.5
    • /
    • pp.789-797
    • /
    • 2020
  • In this paper, we propose a protocol structure of a portable 4K Ultra High Definition (UHD) broadcast relay device that utilizes a 5G mobile communication network as a transport channel, and construct a prototype to conduct a broadcast relay performance test through a 5G mobile communication network. The test shows that the encoding time of the 4K UHD encoder is from a minimum of 86.28ms to a maximum of 88.41ms, the relay delay time in the 5G mobile communication network is 13.645ms on average, the delay variation is 17.49ms, and the glass-to-glass delay time is 289.90 on average, the delay variation is 27.63ms. Using the developed prototype, a relay test between Seoul and Anseong is conducted, and the possibility of 4K UHD broadcasting through a 5G mobile communication network is confirmed.

Optical, Thermal and Dielectric Properties of $B_2O_3-Al_2O_3$-SrO Glasses for Plasma Display Panel (플라즈마 디스플레이 패널을 위한 $B_2O_3-Al_2O_3$-SrO계 유리의 물리적 특성)

  • Hwang, Seong-Jin;Lee, Jin-Ho;Lee, Sang-Wook;Kim, Hyung-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.33-33
    • /
    • 2007
  • In PDP industry, the dielectrics and barrier ribs have been required with low dielectric constant, low melting point and Pb-free composition due to the low power consumption, low signal delay time and the environment restriction. We were studied with $B_2O_3-Al_2O_3$-SrO glass systems about optical, thermal and dielectric properties. The glass forming region of the $B_2O_3-Al_2O_3$-SrO glass systems was narrow due to the amount of the glass former $(B_2O_3)$. The glass transition temperature (Tg) of the glasses was at $550{\sim}590^{\circ}C$. The glasses have 6~8 for the dielectric constant. Furthermore, the transmittance of the glasses was over 80% on the range of the visible ray. From the results, the glasses of the $B_2O_3-Al_2O_3$-SrO glass systems should enable to be a good candidate of the PDP devices for information display with low dielectric constant. The aim of this study is to give a fundamental result of new glass system for low dielectric constant in the information display.

  • PDF

Switching Phenomena of AsTe Glass Semiconductor (AsTe계 유리반도체의 스위칭현상)

  • 박창엽
    • 전기의세계
    • /
    • v.21 no.1
    • /
    • pp.17-21
    • /
    • 1972
  • Electrical resistivity and switching phenomena in glass semiconductor of AsTe and AsTeGa is studied. Samples sliced from ingot which is air quenched or water quenched, show high resistivity at room temperature. The resistivity of the AsTe and AsTeGa is 1*10$^{6}$ .ohm.-cm and 5*10$^{6}$ .ohm.-cm at 27.deg. C. Switching phenomena take place in thin the thick samples. Holding voltage is different with the thickness of the samples and the characteristics of switching in the thin and thick samhles are similar. When square wave pulse voltage is applied, delay time is detected to 5.mu.sec by oscilloscpoe.

  • PDF

Fabrication Method and Performance Evaluation of Micro Igniter for MEMS Thruster (MEMS 추력기를 위한 마이크로 점화기의 제작 방법 및 성능 평가)

  • Lee, Jongkwang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Micro igniter on the glass membrane for MEMS thruster was developed. The stability of the micro igniter by using a glass membrane with a thickness of tens of microns was improved. The micro igniter was fabricated by anisotropic wet etching of photosensitive glass and deposition of Pt/Ti for electric heat coil. The solid propellant was loaded into the propellant chamber without an especial technique due to the high structural stability of the glass membrane. Ignition tests were performed successfully. The minimum ignition delay was 27.5 ms with an ignition energy of 19.3 mJ.

Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy (레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.137-146
    • /
    • 2004
  • Laser Induced Breakdown Spectroscopy(LIBS) system is being developed as an in-situ analysis system for the radioactive waste glass in the cold crucible melter. In order to complete the LIBS system, a spectrometer, a detector, and a laser were structured. An ESA 3000 (LLA Instruments GmbH, Germany) including a calibrated Kodak KAF-1001 CCD detector was selected as the spectrometer. A Q-switched Nd-YAG Brilliant(Quantel, France) laser was selected as an energy source. As the first research stage, the excitation temperatures of Fe(I) as a function of the detector's delay intervals(500, 1000, 1500, 2000ns) were evaluated using the Einstein-Boltzmann equation. The optimized excitation temperature of Fe (I) was 7820k at the delay time of 1500㎱ using the 532nm Nd-YAG laser pulse. This LIBS system will be optimized under the real environment vitrification facility in the near future and then used to be in-situ analyzed the glass compositions in the melter qualitatively.

  • PDF

Development of Ignition System for MEMS Solid Propellant Thruster (MEMS 고체 추진제 추력기의 점화 시스템 개발)

  • Lee, Jong-Kwang;Park, Jong-Ik;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.91-94
    • /
    • 2007
  • The fabrication and firing test of the ignition system for a micro solid propellant thruster are described in the present paper. Pt igniter coil was patterned on the glass membrane that was fabricated by the wet etching process. The thickness of Pt layer was $2000{\AA}$ and the width of igniter pattern was $40{\mu}m$. The thickness and diameter of glass membrane were $15{\mu}m$ and 1 mm, respectively. Ignition test was performed. Successful ignition of HTPB/AP propellant was obtained with an ignition delay of 1.6 s at an input voltage of 12 V. The ignition energy was estimated to be 1.4 J.

  • PDF

Commercial 4K UHD Streaming Device over 5G Mobile Communication Network (5G 이동통신망을 통한 상용 4K UHD 스트리밍 장치)

  • Junghoon, Paik;Yongsuk, Kim
    • Journal of Broadcast Engineering
    • /
    • v.27 no.6
    • /
    • pp.914-922
    • /
    • 2022
  • In this paper, we construct a commercial 4K UHD(Ultra High Definition) streaming device that utilizes a 5G mobile communication network as a transport channel and conduct a streaming performance test. It uses RTP(Realtime Transport Protocol) which has transmission quality monitoring capability as a transmission protocol to apply adaptive streaming. In addition, it provides the function to adjust the encoding rate of the video signal so that encoding can be optimized for the change in the bandwidth of the transmission channel. Through the performance test, it is confirmed that the H.265 encoding rate for 4K UHD signal is 48.69Mbps, the average glass-to-glass delay time is 293.60ms, and the average time difference between video and audio for lip sync is 120ms. With the result of performance test, it is shown that the streaming device is applied to 4K UHD Streaming device over 5G mobile communication network.

A Study on Characteristic of Glass Dosimeter According to Graded Change of Tube Current (유리선량계의 단계별 관전류량 변화에 따른 특성연구)

  • Son, Jin-Hyun;Kim, Seong-Ho;Mun, Hyun-Jun;Kim, Lyun-Kyun;Son, In-Hwa;Kim, Young-Jun;Min, Jung-Whan;Kim, Ki-Won
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.135-141
    • /
    • 2014
  • This study was evaluated the linearity and reproducibility according to dose, and reproducibility according to delay time by changing tube current amount (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively, which are low energy radiations) using Glass Dosimeter (GD) and piranha semiconductor dosimeter which are used for measuring exposure dose. Measurements of radiation dose were performed using external detector of piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Conditions of measurement were 80 kVp, SSD 100 cm and exposure region is $10cm{\times}10cm$. Glass dosimeter was exposed to radiation. Twenty-four glass dosimeters were divided into six groups (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively), then measured. This study was resulted by measuring the linearity and reproducibility according to change of tube current in low energy field. In dose characteristic of GD, this study could be useful as previous study with regard to dose characteristic according to change of tube voltage in low energy field.