• 제목/요약/키워드: Glass-to-Glass Delay

검색결과 37건 처리시간 0.033초

지상 전투 차량을 위한 다채널 영상 스트리밍 시스템의 회전 구동 대비 품질과 압축 대비 지연 분석 (Rotational Drive-Versus-Quality and Video Compression-Versus-Delay Analysis for Multi-Channel Video Streaming System on Ground Combat Vehicles)

  • 윤지혁;조영걸;장혜민
    • 한국군사과학기술학회지
    • /
    • 제24권1호
    • /
    • pp.31-40
    • /
    • 2021
  • The multi-channel video streaming system is an essential device for future ground combat vehicles. For the system, the application of digital interfaces is required instead of the direct analog method to support selectable multiple channels. However, due to the characteristics of the digital interfaces that require en/decoding and signal conversion, the system should support the ability to adapt to quality and delay requirements depending on how video data is utilized. To support addressed issue, this study designs and emulates the multi-channel compressed-video streaming system of ground combat vehicle's fire control system based on commercial standards. Using the system, this study analyzes the quality of video according to the rotational speed of the acquisition device and Glass-to-Glass (G2G) delay between video acquisition and display devices according to video compression rates. Through these experiments and analysis, this paper presents the design direction of the system having scalability on the latest technology while providing high-quality video data streaming flexibly.

저에너지X선 영역에서 유리선량계의 preheat과 Non-preheat과의 시간에 따른 build up 특성에 관한 연구 (Experimental study on build up characteristic of glass dosimeter of preheat and Non-preheat in low energy according to delay time)

  • 손진현;민정환;김기원;손순륭;임현수
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3412-3418
    • /
    • 2013
  • 본 논문은 유리선량계를 이용하여 장기간에 걸쳐 방사선의 누적선량측정 시 예비가열(preheat)과정을 수행한 선량값과 예비가열을 수행하지 않은(non-preheat)선량값을 30일간 시간에 따른 선량변화와 빌드업 특성을 비교 평가함을 목적으로 하였다. 저 선량의 0.1 mGy, 1 mGy, 5 mGy의 선량을 얻기 위해 진단용 발생장치 AccuRay-650R을 사용하였다. 관전압, 관전류 조건으로 각각의 10개 총 30개의 유리선량계 GD SC-1에 조사하여 장시간에 걸쳐 빌드업 특성을 비교하였다. 예비가열을 거치지 않은 저선량의 유리선량에서 초기 판독선량값은 조사된 선량값에 미치지 못하다가 시간이 지남에 따라 점차 조사된 선량값으로 증가하는 것으로 나타냈다. 이후 실험 종료 후 예비가열을 실시한 값과 차이를 보이지는 않았으며 통계적으로도 유의한 차이는 없었다(p>0.05). 예비가열을 거친 저선량의 유리선량에서 초기 판독선량은 조사된 선량값에 근접하였고 일정한 안정상태를 보인 후 15일이 경과한 이후 부터는 점차 증가하는 것으로 나타냈다. 결론적으로 앞서 보고된 유리선량계의 특성들은 고에너지영역의 고선량에서 유리선량계의 특성들에 관한 내용으로 본 논문에서는 저에너지를 사용해서 저 선량의 누적 선량을 장시간 측정하고자 하면 예비가열을 실시하지 않고 판독을 해도 무방할 것으로 판단 사료된다.

5G 이동통신망을 전송채널로 활용하는 휴대형 4K UHD 방송중계 장치 (Portable 4K UHD Broadcasting Device using 5G Mobile Network as a Transmission Channel)

  • 백정훈;김용석
    • 방송공학회논문지
    • /
    • 제25권5호
    • /
    • pp.789-797
    • /
    • 2020
  • 본 논문에서는 5G 이동통신망을 전송채널로 활용하는 휴대형 4K UHD(Ultra High Definition) 방송중계 장치의 프로토콜 구조를 제안하고 시제품을 구성하여 5G 이동통신망을 통한 방송중계 시험을 실시한다. 방송중계 시험을 통하여 4K UHD 인코더의 인코딩 시간은 최소 86.28ms 부터 최대 88.41ms 이며, 5G 이동통신망에서의 중계지연 시간은 평균 13.645ms, 지연변이는 17.49ms 이고 Glass-to-Glass 지연시간은 평균 289.90ms, 지연변이는 27.63ms로 측정됨을 확인한다. 개발된 시제품을 활용한 서을과 안성간의 중계 시험을 통해 5G 이동통신망을 통한 4K UHD 방송중계의 가능성을 확인한다.

플라즈마 디스플레이 패널을 위한 $B_2O_3-Al_2O_3$-SrO계 유리의 물리적 특성 (Optical, Thermal and Dielectric Properties of $B_2O_3-Al_2O_3$-SrO Glasses for Plasma Display Panel)

  • 황성진;김진호;이상욱;김형순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.33-33
    • /
    • 2007
  • In PDP industry, the dielectrics and barrier ribs have been required with low dielectric constant, low melting point and Pb-free composition due to the low power consumption, low signal delay time and the environment restriction. We were studied with $B_2O_3-Al_2O_3$-SrO glass systems about optical, thermal and dielectric properties. The glass forming region of the $B_2O_3-Al_2O_3$-SrO glass systems was narrow due to the amount of the glass former $(B_2O_3)$. The glass transition temperature (Tg) of the glasses was at $550{\sim}590^{\circ}C$. The glasses have 6~8 for the dielectric constant. Furthermore, the transmittance of the glasses was over 80% on the range of the visible ray. From the results, the glasses of the $B_2O_3-Al_2O_3$-SrO glass systems should enable to be a good candidate of the PDP devices for information display with low dielectric constant. The aim of this study is to give a fundamental result of new glass system for low dielectric constant in the information display.

  • PDF

AsTe계 유리반도체의 스위칭현상 (Switching Phenomena of AsTe Glass Semiconductor)

  • 박창엽
    • 전기의세계
    • /
    • 제21권1호
    • /
    • pp.17-21
    • /
    • 1972
  • Electrical resistivity and switching phenomena in glass semiconductor of AsTe and AsTeGa is studied. Samples sliced from ingot which is air quenched or water quenched, show high resistivity at room temperature. The resistivity of the AsTe and AsTeGa is 1*10$^{6}$ .ohm.-cm and 5*10$^{6}$ .ohm.-cm at 27.deg. C. Switching phenomena take place in thin the thick samples. Holding voltage is different with the thickness of the samples and the characteristics of switching in the thin and thick samhles are similar. When square wave pulse voltage is applied, delay time is detected to 5.mu.sec by oscilloscpoe.

  • PDF

MEMS 추력기를 위한 마이크로 점화기의 제작 방법 및 성능 평가 (Fabrication Method and Performance Evaluation of Micro Igniter for MEMS Thruster)

  • 이종광
    • 한국추진공학회지
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2015
  • MEMS 추력기를 위한 유리 박막 마이크로 점화기를 개발하였다. 수십 마이크로 미터의 두께를 가지는 유리 박막을 사용하여 점화기의 구조적 안정성을 향상시켰다. 마이크로 점화기는 박막 형성을 위한 감광 유리의 이방성 식각과 점화 코일 형성을 위한 Pt/Ti 증착 공정으로 제작되었다. 개발된 점화기는 유리 박막의 구조적 안정성으로 인하여 특별한 장치없이 추진제 충전이 가능하였다. 점화 실험이 성공적으로 이뤄졌으며 최소 점화 지연은 27.5 ms, 최소 점화 에너지는 19.3 mJ 이였다.

레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발 (Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.137-146
    • /
    • 2004
  • 방사성폐기물 유리화 공전 중 용융로 내에서 유리시료를 직접분석 하기 위한 레이저유도 플라즈마분광법(LIBS: Laser Induced Breakdown Spectroscopy)을 개발 중이다. LIBS 시스템을 구성하기 위하여 분광기, 검출기, 레이저 등의 장비들을 구축하였다. 분광기는 CCD(charge coupled device)가 보정되어 내장되어있는 ESA 3000을 레이저는 Q-switched Nd-YAG인 Brilliant로 구매하여 분석시스템을 구축하였다. 구축된 분석시스템 분야별 성능들을 확인하였으며 최적화 연구를 수행하였다. 첫 번째 단계로 Fe가 함유된 시료에 레이저를 주사하였을 때 발광스펙트럼을 측정하였으며 검출기의 지연시간을 변화시켰을 때의 발광스펙트럼의 특성과 이를 이용한 여기온도를 Einstein-Boltzmann 식을 이용하여 계산하였다. 시료에 532nm Nd-YAG 레이저를 주사하고 검출기의 지연시간을 500, 1000, 1500, 2000ns로 변화시켰을 때의 분광선의 intensity 및 여기온도 변화를 분석하였다. 그 결과 검출시간이 1500㎱ 일 때 여기온도는 7820k로 가장 최적의 상태를 확인하였다. 향후 이 시스템은 유리화 실증시설에 적용되어 용융로 외부로의 유리시료 이송 없이 현장에서 유리성분들의 정량분석을 수행할 예정이다.

  • PDF

MEMS 고체 추진제 추력기의 점화 시스템 개발 (Development of Ignition System for MEMS Solid Propellant Thruster)

  • 이종광;박종익;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.91-94
    • /
    • 2007
  • 마이크로 고체 추진제 추력기의 점화 시스템의 제작 및 점화 실험에 관한 연구 결과를 기술하겠다. 유리 박막 마이크로 백금 점화기는 일반적인 금속 박리 공정과 감광 유리 제작 공정을 이용하여 제작되었다. 백금 층의 두께는 $2000{\AA}$, 점화기 패턴의 폭은 $40{\mu}m$ 였다. 제작된 유리 박막의 두께는 $15{\mu}m$, 유리 박막의 지름은 1 mm 였다. HTPB/AP 추진제를 이용하여 점화 실험을 수행하였다. 12 V의 전압을 사용한 경우, 점화 지연 시간은 1.6 s 였으며 이 때의 점화 에너지는 1.4 J로 측정되었다.

  • PDF

5G 이동통신망을 통한 상용 4K UHD 스트리밍 장치 (Commercial 4K UHD Streaming Device over 5G Mobile Communication Network)

  • 백정훈;김용석
    • 방송공학회논문지
    • /
    • 제27권6호
    • /
    • pp.914-922
    • /
    • 2022
  • 본 논문에서는 5G 이동통신망을 전송채널로 활용하는 4K UHD(Ultra High Definition) 상용 스트리밍 장치를 구성하고 성능시험 결과를 제시한다. 스트리밍 장치는 전송품질에 대한 모니터링 기능을 제공하는 RTP(Realtime Transport Protocol)를 전송 프로토콜로 적용하여 적응형 스트리밍 기능을 제공한다. 또한, 전송채널의 대역폭 변화에 최적화된 인코딩을 위하여 영상신호의 인코딩률을 조절할 수 있는 기능을 제공하며, 세 개의 5G 이동통신망과 인터페이스 되어 특정 채널에서의 장애 발생 시 다른 채널을 통해 스트리밍하는 자동 절체 기능도 제공한다. 성능시험을 통하여 4K UHD 신호에 대한 H.265 인코딩률은 48.69Mbps, Glass-to-Glass 평균 지연시간은 293.60ms, 립싱크를 위한 비디오 및 오디오의 평균 시간 차이는 120ms 수준임이 확인되어, 개발제품이 5G 이동통신망을 통한 4K UHD 스트리밍 장치로 적용될 수 있음을 보인다.

유리선량계의 단계별 관전류량 변화에 따른 특성연구 (A Study on Characteristic of Glass Dosimeter According to Graded Change of Tube Current)

  • 손진현;김성호;문현준;김륜균;손인화;김용준;민정환;김기원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.135-141
    • /
    • 2014
  • 개인의 피폭선량 측정에 사용되는 유리선량계 (Glass Dosimeter; GD)와 선량측정용 Piranha 반도체 선량계를 이용하여 진단방사선영역에서 사용하는 저에너지 X-선 영역에서 관전류량을 변화시켜 (5mAs, 10mAs, 16mAs, 20mAs, 25mAs, 32mAs의 저에너지 방사선) 측정하여 선량에 따른 선형성과 재현성, 그리고 지연시간에 따른 재현성을 평가하였다. 방사선량 측정은 다기능 QA 측정기 (RTI Electronic, Sweden)인 Piranha 657의 external detector로 측정하였다. 측정 조건은 80 kVp, SSD 100 cm로 조사영역은 $10cm{\times}10cm$으로 하였으며 유리선량계에 방사선을 조사하였다. 24개의 유리선량계들은 6 개의 그룹 (5mAs, 10mAs, 16mAs, 20mAs, 25mAs, 32mAs)로 나누고 측정을 하였다. 본 연구는 저 에너지 영역에서 관전류를 변화시켜 선형성 및 재현성을 측정한 결과이며, 유리선량계의 선량 특성에서 앞선 연구의 관전압 변화에 따른 특성과 같이 저 에너지 영역에서도 유용할 것으로 사료된다.