• 제목/요약/키워드: Glass tube

검색결과 328건 처리시간 0.027초

수지가공시 중에 잔존한 유리 Formaldehyde에 관한 연구 (The study of free formaldehyde remained in resin finished fabrics)

  • 송화순;조승식;김성련
    • 한국의류학회지
    • /
    • 제2권1호
    • /
    • pp.125-131
    • /
    • 1978
  • This study was intended to clarify (1) the release of free formaldehyde (2) transfer of free formaldehyde to the contacted fabrics during storing, and (3) the removal effect of free formaldehyde by washing from resin finished fabrics. The results of this study were as follow; 1. The decrease rate of free formaldehyde content in fabrics was higher during storing in open air, poly bag, and glass tube in descending order and the content of free formaldehyde in fabrics was decreased in glyoxal resin finished but, increased in Melamine M-3 resin finished when the fabrics was stored in polybag and in glass tube. 2. Increased amount of formaldehyde transfer to contacted fabrics was noted with Melamine M-3 resin finished than that of glyoxal resin finished. Increased amount of formaldehyde transfer as well as more free formaldehyde were noted in cotton fabrics than in polyester/ cotton blend. 3. The effect of removing free formaldehyde from the fabrics was better in case of solid alkaline soap, synthetic alkaline powdered detergents, neutral detergents in descending order. The romoval of free formaldehyde was marked after the 1st washing and almost no increase in free formaldehyde was found after three times of washing. 4. After first washing, the content of formaldehyde in Melamine M-3 resin finished fabrics increased more rapidly than that of glyoxal resin finished fabrics in condition of closed storing.

  • PDF

외부전극 헝광램프의 핀홀 현상 (Pinhole Phenomena in the External Electrode Fluorescent Lamps)

  • 길도현;김상범;송혁수;유동근;이상훈;박민순;강준길;조광섭;조미령;황명근;김영욱
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.266-272
    • /
    • 2006
  • 외부전극 형광램프의 구동에서 과도한 전력을 인가하면, 외부전극 부분의 유리관 표면에 작은 원형의 구멍(핀홀)이 발생하여 램프가 파손된다. 핀홀은 외부전극과 유리관을 유전층으로 하는 캐패시터의 절연파괴이며, 이러한 절연파괴력은 인가되는 전력에 비례한다. 유전상수가 K인 램프에 흐르는 전류가 작을 때, 핀홀이 발생하는 유리관의 절연파괴 전기장의 세기는 약 3K kV/mm,이다. 이러한 절연파괴 전기장의 세기는 램프에 흐르는 전류가 커질수록 작아진다.

펄스와전류를 이용한 보온재 비해체식 배관감육 평가기술 (Nondestructive evaluation of wall thinning covered with insulation using pulsed eddy current)

  • 박덕근;;이덕현
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.90-95
    • /
    • 2014
  • Local wall thinning is a point of concern in almost all steel structures such as pipe lines covered with a thermal insulator made up of materials with low thermal conductivity(fiberglass or mineral wool); hence, Non Destructive Technique(NDT) methods that are capable of detecting the wall thinning and defects without removing the insulation are necessary. In this study we developed a Pulsed Eddy Current(PEC) system to detect the wall thinning of Ferro magnetic steel pipes covered with fiber glass thermal insulator and shielded with Aluminum plate. The developed system is capable of detecting the wall thickness change through an insulation of thickness 10cm and 0.4mm aluminum shielding. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and coil sensor were used as a detecting element. In both cases, the results show a very good change corresponding to the thickness change of the test specimen. During these experiments a carbon steel tube of diameter 210mm and a length of 620mm, which is covered with insulator of 95mm thickness was used. To simulate the wall thinning, the thickness of the tube is changed for a specified length such as 2.5mm, 5mm and 8 mm from the inner surface of the tube. A 0.4mm thick Aluminum plate was covered on the Test specimen to simulate the shielding of the insulated pipelines. For both hall sensor and coil detection methods Fast Fourier transform(FFT) was calculated using window approach and the results for the test specimen without Aluminum shielding were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra. The PEC system can detect the wall thinning under the 95 mm thickness insulation and 0.4 mm Al shielding, and the output signal showed linear relation with tube wall thickness.

밀폐형 2상 열사이폰내의 비등현상에 관한 가시화 연구 (A Visual Study on Nucleate Boiling Phenomena in a Closed Two-Phase Thermosyphon)

  • 강환국;오광헌;김철주;박이동;황영규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.185-198
    • /
    • 1995
  • This is an experimental study conducted to visualize the nucleate boiling phenomena and flow regimes occurring inside the liquid pool in a closed two-phase thermosyphon. To meet this purpose, an annular-type thermosyphon was designed and manufactured using a glass tube and a stainless steel tube, being assembled axisymmetrically. The heat to be supplied to the working fluid is generated within a very thin layer of stainless steel tube wall by applying a high frequency electromagnetic field through the induction coil, axisymmetrically set around the evaporator zone. Some important results were as follows ; 1) Considering the structural complexity of the tested thermosyphon, it showed good performance for the range of heat flux 2< q" <25kW/$m^2$ and saturation vapor pressure, 0.1<Pv<1.1bar 2) different type of nucleating boiling regimes were observed as described below, -Pulse boiling regime : Flow pattern changed cyclically with time during 1 cycle of pulse boiling process. The onset of Nucleation was followed by expulsive growing of vapor bubble, resulting in the so called blow-up phenomenon, massive expulsion of large amount of liquid around the bubble. -Transient : Some spherical vapor bobbles were observed growing out from 2~3 nucleating sites, that was dispersed at the lower part of the heated tube wall in the liquid pool. But the rest upper region above the nucleating sites were filled with churns or bubbles of vapor. -Continuous nucleate boiling regime : The whole zone of evaporator was filled with lots of spherical vapor bubbles, and the bubbles showed tendency to decrease in diameter as the heat flux increased.ased.

  • PDF

Measurement of outgassing rates of Kevlar and S-Glass materials used in torque tubes of High Tc Superconducting (HTS) Motors

  • Thadela, S.;Muralidhar, BVAS;Kalyani, B;Choudhury, UK;Yadav, SN;Rao, V.V.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.11-15
    • /
    • 2018
  • Torque tubes in High Temperature Superconducting (HTS) motor transfer torque from superconducting field winding rotor to the room temperature shaft. It should have minimum heat conduction property for minimizing the load on cryo-refrigerator. Generally, these torque tubes are made with stainless steel material because of high strength, very low outgassing and low thermal contraction properties at cryogenic temperatures and vacuum conditions. With recent developments in composite materials, these torque tubes could be made of composites such as Kevlar and S-Glass, which have the required properties like high strength and low thermal conductivity at cryogenic temperatures, but with a reduced weight. Development and testing of torque tubes made of these composites for HTS motor are taken up at Bharat Heavy Electricals Limited (BHEL), Hyderabad in collaboration with Central Institute of Plastics and Engineering Technology (CIPET), Chennai and Indian Institute of Technology (IIT), Kharagpur. As these materials are subjected to vacuum, it is important to measure their outgassing rates under vacuum conditions before manufacturing prototype torque tubes. The present study focusses on the outgassing characteristics of Kevlar and S-Glass, using an Outgassing Measurement System (OMS), developed at IIT Kharagpur. The OMS facility works under vacuum environment, in which the test samples are exposed to vacuum conditions over a sufficient period of time. The outgassing measurements for the composite samples were obtained using pressure-rise technique. These studies are useful to quantify the outgassing rate of composite materials under vacuum conditions and to suggest them for manufacturing composite torque tubes used in HTS motors.

탄소나노튜브 전극의 전기화학적 특성 (Electrochemical Properties of Carbon Nano-Tube Electrode)

  • 이동윤;구보근;이원재;송재성;김현주
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권4호
    • /
    • pp.139-143
    • /
    • 2005
  • For application of carbon nano-tube (CNT) as a counter electrode materials of dye-sensitized solar cell (DSSC), the electrochemical behavior of CNT electrode was studied, employing cyclic-voltammetry (C-V) and impedance spectroscopy. Fabrication of CNT-paste and formation of CNT-counter electrode for characteristic measurement have been carried out using ball-milling and doctor blade process, respectively. Unit cell for measurements was assembled using Pt electrode, CNT electrode, and iodine-embedded electrolyte. Field emission-scanning electron microscopy (FE-SEM) was used for structural investigation of CNT powder and electrode. Sheet resistance of electrode was measured with 4-point probe method. Electrochemical properties of electrode, C-V and impedance spectrum, were studied, employing potentiogalvanostat (EG&G 273A) and lock in amplifier (EG&G 5210). As a results, the sheet resistance of CNT electrode is almost similar to that of F-doped SnO2 (FTO) coated glass substrate as approximately 10 ohm/sq. From C-V and impedance spectroscopy measurements, it was found that CNT electrode has high reaction rate and low interface reaction resistance between CNT surface and electrolyte. These results provides that CNT electrode were superior to that of conventional Pt electrode. Particularly, the reaction rate in the CNT electrode is about thrice high than Pt electrode. Therefore. CNT electrode is to be good candidate material for counter electrode in DSSC.

수중에서 구형 유전체와 단층 절연 방전관의 전계 분포 시뮬레이션 (The Simulation of Electric Field Distribution of Dielectric Tube with Single Layer and Globular Dielectric in Water)

  • 이동훈;박재윤;이재동;박홍재;고희석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1119-1122
    • /
    • 2003
  • In this paper, the electric field distribution in dielectric tube with one layer and spherical dielectric in water was simulated. The reactor was made up of the spherical dielectric that is diameter 2.5[mm], ${\epsilon}_r$ : 5, 100, 1000, 5000 respectively and one glass plate being 2[mm] thickness, ${\epsilon}_r$ : 5 as electrode. The discharge gap was 7[mm]. As a result of the simulation, in case of being about the same value between the dielectric constant of spherical dielectric and water, when the reactor was applied to high voltage dielectric polarization characteristic was trending toward disappearance. To get more strong electric field, the dielectric constant should be higher comparatively, Increasing the spherical dielectric constant, the location of equippotential line was shifting from the interior to the exterior.

  • PDF

수중에서의 이중 절연 방전관과 구형 유전체의 전계 분포 시뮬레이션 (The Simulation of Electric Field Distribution of Dielectric Tube with Two Layers and Gloular Dielectric in Water)

  • 이동훈;박재윤;박홍재;고희석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1143-1146
    • /
    • 2003
  • This paper was simulated the electric field distribution in dielectric tube with two layers and spherical dielectric in water. The reactor was made up of the spherical dielectric that is diameter : 2.5[mm], ${\epsilon}_r$ : 5, 25, 100, 1000, 5000 respectively and two glass plate being 2[mm] thickness, ${\epsilon}_r$ : 5 as electrode. The discharge gap was 9[mm]. As a result of the simulation, in case of being about the same value between the dielectric constant of spherical dielectric and water, when the reactor was applied to high voltage, dielectric polarization characteristic was trending toward disappearance. To get more strong electric field, the dielectric constant should be higher comparatively, Increasing the spherical dielectric constant, the location of equippotential line was shifting from the interior to the exterior.

  • PDF

폐흡충증으로 인한 대량 기흉 (Massive pneumothorax resulting from paragonimiasis)

  • 임우희;김수완
    • Journal of Medicine and Life Science
    • /
    • 제17권1호
    • /
    • pp.25-28
    • /
    • 2020
  • The prevalence of pulmonary pargonimiasis in Korea has been steadily decreasing due to develop of the public health, and there have been few clinical cases of paragonimiasis infections, especially in pneumothorax. A 22-year-old man referred to emergency department for dyspnea and chest pain. The right lung was totally collapsed on a chest X-ray. We emergently performed a closed thoracostomy with a 28-Fr chest tube. However, the air leak from the chest tube persisted for three days after the closed thoracostomy. A chest computed tomography showed multiple subpleural consolidative nodular lesions and mixed ground-glass attenuation nodules. We potentially suspected a secondary pneumothorax resulting from pulmonary paragonimiasis infection because the patient was a Chinese man who was working at a Korean restaurant. We decided to perform a medical treatment instead of pulmonary wedge resections. The air leak was discontinued three days after the prescription of praziquantel. The patient was discharged nine days after the admission. We suggest that anti-parasitic drugs are very effective in the secondary pneumothorax resulting from paragonimiasis.

황화급속열처리를 이용한 SnS 박막성장 및 온도의존성 연구 (Study of Growth and Temperature Dependence of SnS Thin Films Using a Rapid Thermal Processing)

  • 심지현;김제하
    • 한국전기전자재료학회논문지
    • /
    • 제29권2호
    • /
    • pp.95-100
    • /
    • 2016
  • We fabricated a tin sulfide (SnS) layer with Sn/Mo/glass layers followed by a RTP (rapid thermal processing), and studied the film growth and structural characteristics as a function of annealing temperature and time. The elemental sulfur (S) was cracked thermally and applied to form SnS polycrystalline film out of the Sn percursor at pre-determined pressures in the RTP tube. The sulfurization was done at the temperature from $200^{\circ}C$ to $500^{\circ}C$ for a time period of 10 to 40 min. At ${\leq}300^{\circ}C$, 20 min., p-type SnS thin films was grown and showed the best composition of at.% of [S]/[Sn] $${\sim_=}$$ 1 and [111] preferred orientation as investigated from using XRD (X-ray diffraction) analysis and EDS (energy dispersive spectroscopy) and SEM (scanning electron microscopy), and optical absorption by a UV-VIS spectrometer. In this paper, we report the details of growth characteristics of single phase SnS thin film as a function of annealing temperature and time associated with the pressure and ambient gas in the RTP tube.