• 제목/요약/키워드: Glass mold

검색결과 295건 처리시간 0.027초

비탈형 영구거푸집의 현장 적용을 위한 실험적 연구 (An Experimental study on field application of Permanent form)

  • 정근호;김우재;이영도;정재영;정상진
    • 한국건축시공학회지
    • /
    • 제1권1호
    • /
    • pp.143-150
    • /
    • 2001
  • Permanent-Form is one of system forms for reducing human labor, work costs, oscillation, noise, construction wastes and so on. Permanent-Form is made from precast method in facilities, and carried in construction site to assemble with no demolding. The biggest expense to produce permanent-Form is about manufacturing mold. This papers about structural efficiency evaluation, construction efficiency test. The result of this study is below. (1) In the compressive strength test of column. Fly ash specimen and polymer specimen's strength developed as each 8%, 14% to comparison with standard specimen. The reason of this result from form section area increase and form's reinforcing bar (2) The Degree of column crack in permanent form is lower than another one's The glass fiber's fiber reinforcement effect brings like this. (3) In the flexural load test of beam, the early crack load and maximum load of permanent form use specimen showed 20% higher than standard specimen's. (4) In field application experiment, an constructional error is satisfied with the allowable margin of error, $\pm$5mm (5) When the concrete is placed into the form inside, The transformation degree of permanent form is lower than plywood form's. (6) The concrete packing ability of permanent form is satisfactory. (7) The bonding strength of permanent form shows enough strength - 6kgf/$\textrm{cm}^2$.

  • PDF

미세유로채널의 새로운 제작공정 및 표면상태가 유동에 미치는 영향 (Novel Fabrication Process for Micro-Fluidic Channels and the Effect of the Surface States on the Fluid Flow)

  • 박미석;김진산;성인하;김대은;신보성
    • 한국정밀공학회지
    • /
    • 제21권1호
    • /
    • pp.87-93
    • /
    • 2004
  • Recently, with the development of bio-technology the interests in the micro-fluidic devices for analysis in the fields of biology and medical science have been steadily increasing. Although polymer is considered as one of the best materials for micro-fluidic devices. glass or silicon molds fabricated by photo-lithographic technique have been commonly used. However, it is generally perceived that the conventional photolithographic technique has the limitation for fabricating micro-channels for micro-fluidic devices. In this work, the possibility of fabrication of micro-fluidic channels on PDMS by using the mechano-chemical process and the effect of surface states on the fluid flow were investigated. Experimental results revealed that PDMS mold fabricated by the mechano-chemical process could be used effectively to replicate micro-fluidic channels with high reproducibility and dimensional accuracy. It was also found that the fluid flow generation and flow speed were largely affected by the hydrophilicity and the surface roughness of the micro-channel surfaces.

소형렌즈 성형시스템의 힘제어에 관한 연구 (Force Control of Small Lens Molding System)

  • 김갑순;국금환;신희준;김현민;정동연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1091-1096
    • /
    • 2007
  • This paper describes the development of a small lens molding system for manufacturing the small lens like lens of a cellular phone, a small digital camera and so on. In order to manufacture a small lens, firstly, the raw material for lens with spherical shape should be manufactured by processing a glass, secondly, the mold inserted the raw material for lens should be heated till its molding temperature in the electric furnace, finally, the small lens is manufactured by applying the force using pressuring control system. In this paper, the small lens molding system with the function of force control and velocity control was developed. It is composed of a electric furnace and its temperature control system, a pressuring control system, a body, and so on. The temperature characteristic test of the electric furnace, and the force and velocity characteristic test of the pressuring control system were carried out. It was confirmed that the developed system had good functions for manufacturing a small lens.

  • PDF

소형렌즈 성형시스템 개발 및 힘제어에 관한 연구 (Development of Molding System for Manufacturing a Small Lens and Its Force Control)

  • 국금환;정동연;김갑순
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.57-64
    • /
    • 2008
  • This paper describes the development of a small lens molding system for manufacturing the small lens like lens of a cellular phone, a small digital camera and so on. In order to manufacture a small lens, firstly, the raw material for lens with spherical shape should be manufactured by processing a glass material, secondly, the mold inserted the raw material for lens should be heated till its molding temperature in the electric furnace, finally, the small lens is manufactured by applying the force using pressuring control system. In this paper, the small lens molding system with the function of force control and velocity control was developed. It is composed of an electric furnace and its temperature control system, a pressuring control system, a body, and so on. The temperature characteristic test of the electric furnace, the force and velocity characteristic test of the pressuring control system were carried out. It was confirmed that the developed system had good functions for manufacturing a small lens.

비드를 이용한 면역분석용 마이크로필터 칩의 제작 (Microfilter Chip Fabrication for Bead-Based Immunoassay)

  • 이승우;안유민;채영규
    • 대한기계학회논문집A
    • /
    • 제28권9호
    • /
    • pp.1429-1434
    • /
    • 2004
  • Immunoassay is one of the important analytical methods for clinical diagnoses and biochemical studies, but needs a long time, troublesome procedures and expensive reagents. In this study, therefore, we propose the micro filter chip with microbeads for immunoassay, which has pillar structures. The advantage of the proposed micro filter chip is to use simple fabrication process and cheap materials. The mold was made by the photolithography technique with Si wafer and negative photoresist SU-8. The replica was made of PDMS, bonded on the pyrex glass. The micro filter chip consists of inlet channel, filter chamber and outlet channel. HBV (Hepatitius B virus) monoclonal antibody (Ag1) labeled with biotin were immobilized onto streptavidin coated beads of 30∼50 $\mu$m size. Fluorescein isothiocyanate (FITC)-labeled HBV monoclonal antibody (Ag8) was used to detect HBsAg (Hebatitis B virus surface Antigen), and fluorescence intensity was monitored by epi-fluorescence microscope. In this study, the immune response of less than 30 min was obtained with with the use of 100 $m\ell$ of sample.

면광원 램프 및 이를 이용한 조명 기기의 효율 특성 연구 (Flat Fluorescent Lamp(FFL) and Analysis of Optical Efficiency of FFL Lighting)

  • 박종리;임성규
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.6-12
    • /
    • 2007
  • LCD(liquid crystal display) TV용 백라이트의 광원으로서 면광원이 개발되었으며, 이를 이용한 조명 기기를 제작 및 평가하였다. 면광원은 유리성형을 통하여 채널을 형성하였으며 채널의 모양을 최적화하여 면광원을 이용한 조명 기기의 효율을 향상시킬 수 있었다. 본 논문에서는 특히 현재 주로 사용되고 있는 형광등과의 비교 평가를 통하여 조명용 면광원의 광 효율 및 조도 특성에 관한 성능을 평가하였다. 채널의 구조가 최적화된 면광원을 이용하여 제작된 32"형 조명 기기의 광 효율은 72.7[1m/W]이었다.

전기장을 이용한 나노와이어 희석기 제작 (Fabrication of a nanowire diluter using electrical fields)

  • 양진호;윤현중;양의혁;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1484-1485
    • /
    • 2008
  • The control of the number and dimension of nanowires is essential for dielectrophoretic(DEP) nanoscale assembly process. However, it is difficult to control the number of nanowires assembled between the electrodes. We have developed a nanowire diluter device, which consists of a glass substrate with gold electrodes and a PDMS layer with microchannel. The diluter device is fabricated by the conventional and soft lithographies using a SU-8 mold. Nickel nanowires (30${\mu}m$-long) are fabricated by a template-directed electrodeposition process using nanoporous alumina templates. A solution containing nanowires is injected into an inlet whereby pulsed voltages are applied to 16 pairs of electrodes in this experiment. The nanowires are trapped or released depending on the pulsed electric field from inlet to outlet (the channel). Therefore, the number of nanowires can be decreased correspondingly if the fixed frequency at each electrode is decreased from electrode to electrode.

  • PDF

RGB 레이저 가시화를 위한 축대칭 구면 f-${\theta}$ 렌즈 설계 및 프로젝션응용 (A Study of f-${\theta}$ Lens Design for Axisymmetric Spherical Surface for RGB Laser Display and its applications)

  • 이영민;최해운
    • 한국레이저가공학회지
    • /
    • 제14권2호
    • /
    • pp.24-29
    • /
    • 2011
  • The design of a telecentric f-${\theta}$ lens with a field of view (FOV) $30^{\circ}$ and an effective focal length of 1000mm is presented. The optical stop is placed at the front plane and the design is based on a geometric ray tracing technique, and the designed system consists of a series of convex and concave lenses. The designed f-${\theta}$ lens showed a considerable reduction in weight with a simplified structure and resulted in a good performance in the designated FOV. Detail analysis of rays is also presented. 653nm (red laser), 586nm (green laser), and 468nm (blue laser) were simulated as a light source and image illuminating source. The developed optical design requires 7 pieces of lenses made of SF1, N-FK56, N-LAK33, and BK7 glass materials. With optimal parametric design, the effective focal length was calculated to be 974.839mm which is very close to the initial design target. For the manufacturing purpose, the dimensions of lens curvature and thickness were truncated with error ranging 0.1% to 3.2%. As a result, the overall error was calculated to be 3.2% which can be still tolerable for display, laser material, and machining processing.

  • PDF

폴리머 2D 캠버 보상을 위한 레이저용접 기술 (A Study of Laser Joining for Polymer 2D Camber Compensation)

  • 이영민;윤진영;송치훈;최해운
    • 한국레이저가공학회지
    • /
    • 제15권2호
    • /
    • pp.15-20
    • /
    • 2012
  • A novel joining technology was developed to compensate the camber in polymers. The preheating laser beam circulates on the joining location and the accumulated heat serves to increase the flexibility of neighboring polymers. The temperature rises up to the glass transient temperature of the polymers and continually loading spring force closes the gap of camber. The irradiated laser was 808nm central wavelength and the power varied between 2Watt and 5Watt. The laps were adjusted between 3 and 10 and the optimum process parameters were 3Watt and 5 laps for the specific application. An FEM analysis was introduced to understand the mechanism of joining by the transient temperature distribution on the polymers. Thermocouples experiments were also tried to correlate the numerical analysis results and it showed the trend of heat accumulation in experiments.

  • PDF

유연 프로펠러의 제작 정도가 단독성능에 미치는 영향 (Effect of Manufacturing Accuracy of Flexible Propeller on the Open Water Performance)

  • 이건화;장현길;이창섭;노인식;이상갑;현범수
    • 대한조선학회논문집
    • /
    • 제50권5호
    • /
    • pp.349-354
    • /
    • 2013
  • The blades of flexible propellers are formed by overlaying and adhering many layers of thin glass-fiber fabric sheets, are compressed and dried in the rigid mold. The current manufacturing process can not avoid the rather irregular deformation of the blades composed of non-isotropic non-uniform fabric structures, and inevitably introduces the different shape-forming errors between blades. In this paper, several flexible model propellers are precisely measured with three-dimensional optical instrument and compared with the original design geometry. The model propellers with the as-measured geometry are evaluated with the lifting-surface-theory-based propeller analysis code. The open-water performance are presented and discussed. The importance of the manufacturing accuracy is addressed to be able to apply the flexible propellers for propulsion of marine vehicles.