• 제목/요약/키워드: Glass infiltrated zirconia

검색결과 10건 처리시간 0.012초

지르코니아 세라믹의 Glass-infiltration에 의한 2축 굽힘강도에 관한 연구 (Study on Biaxial Flexural Strength by Glass-infiltration of Zirconia Ceramics)

  • 주규지;정종현;송경우
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.41-47
    • /
    • 2008
  • This study was to evaluate the biaxial flexural strength of zirconia ceramics after glass-infiltration on zirconia core. The zirconia specimens were made with diameter-15mm, thickness-0.6mm using zirconia block which divided into 1) sintered group, 2) heat - treated group, 3) Glass - infiltrated group and experimented fracture strength by each 10 specimens in experimental group. The biaxial flexural test was performed at crosshead speed of 0.1${\beta}\;{\AE}$ min. The experiment result average fracture strength was shown 541.0${\beta}\acute{A}$ in sintered group and glass-infiltrated group as 662.2${\beta}\acute{A}$ river of 22.4% rise appear. Weibull coefficient sintered group is 3.462 and glass-infiltrated group improved believability about fracture strength from melting permeation processing of glass by 4.716.

  • PDF

유리침투 지르코니아 복합체의 굴곡 강도 (Flexure Strength of Glass-infiltrated Zirconia Complex)

  • 김사학
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, to improve the flexure strength of Zirconia, on the Zirconia pellet surface measure the flexure strength to melt or permeate the Alumina (Vita Zahnfabrik, Bad Sachkingen, Germany) of private used In-Cream and observe by Scanning election microscope. In the control group(3Y-TZP group), the average of flexure strength was 1623.7MPa, and in the experimental group(Glass-infiltrated 3Y-TZP group) was 1800.2MPa. As a result of observing the interface between glass and zirconia with a scanning election microscope, it was showed that the glass dissolves to permeate into the surface of zirconia, so filled the zirconia with particles.

  • PDF

Acid etching of glass-infiltrated zirconia and its biological response

  • Vu, Van Thi;Oh, Gye-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Kim, Ji-Won;Nguyen, Thao Phuong Thi;Park, Sang-Won
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.104-109
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the influence of acid etching treatment on surface characteristics and biological response of glass-infiltrated zirconia. MATERIALS AND METHODS. A hundred zirconia specimens were divided into four groups depending on surface treatments: untreated zirconia (group Z); acid-etched zirconia (group ZE); glass-infiltrated zirconia (group ZG); and glass-infiltrated and acid-etched zirconia (group ZGE). Surface roughness, surface topography, surface morphology, and Vickers hardness of specimens were evaluated. For biological response test, MC3T3-E1 cell attachment and proliferation on surface of the specimens were examined. The data were statistically analyzed using one-way ANOVA and Tukey's HSD test at a significance level of 0.05. RESULTS. Group ZGE showed the highest surface roughness ($Ra=1.54{\mu}m$) compared with other groups (P < .05). Meanwhile, the hardness of group Z was significantly higher than those of other groups (P < .05). Cell attachment and cell proliferation were significantly higher in group ZGE (P < .05). CONCLUSION. We concluded that effective surface roughness on zirconia could be made by acid etching treatment after glass infiltration. This surface showed significantly enhanced osteoblast cell response.

Comparison of two fracture toughness testing methods using a glass-infiltrated and a zirconia dental ceramic

  • Triwatana, Premwara;Srinuan, Phakphum;Suputtamongkol, Kallaya
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.36-43
    • /
    • 2013
  • PURPOSE. The objective of this study was to compare the fracture toughness ($K_{Ic}$) obtained from the single edge V-notched beam (SEVNB) and the fractographic analysis (FTA) of a glass-infiltrated and a zirconia ceramic. MATERIALS AND METHODS. For each material, ten bar-shaped specimens were prepared for the SEVNB method ($3mm{\times}4mm{\times}25mm$) and the FTA method ($2mm{\times}4mm{\times}25mm$). The starter V-notch was prepared as the fracture initiating flaw for the SEVNB method. A Vickers indentation load of 49 N was used to create a controlled surface flaw on each FTA specimen. All specimens were loaded to fracture using a universal testing machine at a crosshead speed of 0.5-1 mm/min. The independent-samples t-test was used for the statistical analysis of the $K_{Ic}$ values at ${\alpha}$=0.05. RESULTS. The mean $K_{Ic}$ of zirconia ceramic obtained from SEVNB method ($5.4{\pm}1.6\;MPa{\cdot}m^{1/2}$) was comparable to that obtained from FTA method ($6.3{\pm}1.6\;MPa{\cdot}m^{1/2}$). The mean $K_{Ic}$ of glass-infiltrated ceramic obtained from SEVNB method ($4.1{\pm}0.6\;MPa{\cdot}m^{1/2}$) was significantly lower than that obtained from FTA method ($5.1{\pm}0.7\;MPa{\cdot}m^{1/2}$). CONCLUSION. The mean $K_{Ic}$ of the glass-infiltrated and zirconia ceramics obtained from the SEVNB method were lower than those obtained from FTA method even they were not significantly different for the zirconia material. The differences in the $K_{Ic}$ values could be a result of the differences in the characteristics of fracture initiating flaws of these two methods.

지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구 (A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system)

  • 이상혁;안진수;김명호;임범순
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.235-242
    • /
    • 2012
  • 연구 목적: 본 연구는 지르코니아, 유리침투알루미나 및 금속도재소부용치관의 파절강도를 비교하고자 하였다. 연구 재료 및 방법: 지르코니아, 유리침투알루미나 및 금속도재소부용합금으로 각각 15개의 치관을 제작한 후, 제작된 치관을 장축에 $30^{\circ}$ 경사지게 제작된 지그에 장착하여 만능시험기로 파절강도를 측정하였으며, 전단결합강도 시험을 위하여 지르코니아, 유리침투알루미나 및 금속도재소부용합금을 $5.5({\phi}){\times}2.5mm$ 크기로 제작하고 포세린 분말을 $3.5({\phi}){\times}2.5mm$ 크기로 축성한 후 제조사의 설명서에 따라 전기로(Ceramco 7, Dentsply, USA)에서 소결하여 총10개의 시편을 제작하였다. 결과: 전부관 형태로 제작한 시편의 파절강도는 금속-도재 시스템이 $569.1{\pm}61.8N$, 알루미나-도재 시스템이 $551.0{\pm}76.5N$ 및 지르코니아-도재 시스템이 $588.3{\pm}49.6N$으로 측정되었으며, 각 실험군간 유의한 차이는 없었다(P>.05). 전단결합강도는 금속-도재 시스템이 $38.9{\pm}5.0MPa$, 알루미나-도재 시스템이 $39.4{\pm}5.1MPa$, 지르코니아-도재 시스템이 $25.5{\pm}5.6MPa$로 지르코니아-도재 시스템이 다른 두 시스템 보다 유의하게 낮은 값을 보였다(P<.05). 금속-도재 시스템, 알루미나-도재 시스템 및 지르코니아-도재 시스템의 각 결합계면을 SEM/EDS로 분석한 결과 각 시스템에서 상이한 결합 양상이 관찰되었다. 결론: 본 연구 결과 지르코니아-도재 시스템의 파절강도가 제일 높았으며, 금속-도재 시스템, 알루미나-도재 시스템 순서로 나타났으며, 전단결합강도는 알루미나-도재 시스템이 제일 높았고 금속-도재 시스템, 지르코니아-도재 시스템 순서으로 나타났다.

글라스 용융침투 처리가 지르코니아와 초저온 소성 도재와의 전단결합강도에 미치는 영향 (Effect of glass-infiltration treatments on the shear bond strength between zirconia and ultra low-fusing porcelain veneer)

  • 임은경;박상원
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.269-277
    • /
    • 2018
  • 목적: 본 연구는 글라스 용융침투 처리가 지르코니아와 초저온 소성 전장도재와의 전단결합강도에 미치는 영향을 평가하였다. 재료 및 방법: 표면처리 방법에 따라 대조군 (처리 안함), ZirLiner처리군 (ZL군), 글라스 용융침투처리군 (ZG군), 글라스 용융침투 후 Sandblasting 처리군 (ZGS군)으로 분류하였다 (n = 12). 모든 실험군은 초저온 소성 전장도재를 사용하여 지름 6 mm ${\times}$ 두께 3 mm가 되도록 축성하고 소성하였다. 지르코니아와 전장도재 사이의 결합강도는 만능시험기를 이용하여 측정하였고 지르코니아 시편의 결합계면, 도재파절 양상은 SEM과 EDX로 관찰하였다. 결과: 지르코니아 표면처리 방법에 따라 전장도재와의 결합강도가 ZirLiner군, 대조군, 글라스 용융침투군 순으로 나타났으나 통계학적으로 유의한 차이는 없었다 (P > .05). 글라스 용융침투 후 Sandblasting 처리군은 다른 모든 군에 비해 유의하게 낮은 전단결합강도를 보였다 (P < .05). 결론: 글라스 용융침투 지르코니아의 Sandblasting처리는 초저온 소성 전장도재와의 현저한 결합력 감소를 야기시키므로 사용이 제한되어야 할 것으로 사료된다.

생체 유리와 소다 유리침투에 따른 알루미나 세라믹의 굴곡 강도 및 PBS에서의 표면 생성물 연구 (Bending strength of alumina coated with bioglass and soda lime glass and the precipitation on the surface of coated alumina in PBS)

  • 유재양
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.39-45
    • /
    • 2008
  • Titanium and its alloys are widely used as dental implants materials because of their excellent mechanical properties. However, the alumina and zirconia ceramics are preferred to use as the substitute of Ti implants because there is a problems in esthetics and biocompatibility in Ti implant. The the glass infiltrated alumina ceramics are studied to increase the toughness and biocompatibility. The 45S5 and soda-lime glass powder was mixed with ethanol at ratio of 1:1 and brushed on the surface of alumina. Then it was heat treated in the electric furnace at $1400^{\circ}C$ from 30 min. to 5 hours. The glass powder was controlled from 200 to $350{\mu}m$ using ball milling. After heat treatment, the glass infiltrated specimen was tested in universal testing machine to measure the bending strength. The surface microstructure of each specimen was observed with SEM. The biocompatibility of 45S5 and soda-lime glass coated alumina was investigated using PBS at $36.5^{\circ}C$ incubator. The specimen was immersed in PBS for 3, 5, 7, 10 days. After that, the surface morphology was investigated with SEM. As the results of experiment, the 45S5 bioglass infiltrated alumina show the increase of bending strength according to the increasing of heat treatment time from 30 min. to 5 hours at $1400^{\circ}C$ Finally the 1370N bending strength of alumina increased to 1958N at 5 hours heat treatment, which shows 1.4 times higher. In contrast to this, the soda lime glass infiltrated alumina ceramics shows the convex curve according to heat treatment time. Thus it shows maximum bending strength of 1820N at 1 hour heat treatment of $1400^{\circ}C$ It gives 1.3 times higher. However, the bending strength of soda lime glass infiltrated alumina is decreasing with increasing heat treatment time after 1 hour. The precipitation on the surface of 45S5 glass infiltrated alumina was revealed as a sodium phosphate ($Na_{6}P_{6}O_{24}6H_{2}O$) and the amount of precipitation is increasing with increasing of immersion time in PBS. In contrast to this, there is no precipitation are observed on the surface of soda lime glass infiltrated alumina. This implies that 45S5 glass infiltrated alumina brings more biocompatible when it is implanted in human body.

  • PDF

다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 미세누출에 관한 연구 (In vitro study of microleakage of endodontically treated teeth restored with different adhesive systems and fiber-reinforced posts)

  • 박준호;최유성
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.74-81
    • /
    • 2014
  • 연구 목적: 포스트로 수복한 치아의 미세누출을 방지하기 위한 다양한 술식이 개발되고 있고 이에 본 연구에서는 다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 치근부 미세누출에 대해 비교 연구하고자 하였다. 연구 재료 및 방법: 36개의 근관치료된 상악 영구 중절치를 3가지 포스트 그룹으로 분류하였다: Zirconia-glass fiber, Quarze-glass fiber, Polyethylene fiber 포스트. 포스트 공간이 형성되었고 각 포스트는 세가지 접착시스템으로 접착되었다: 3-stage total-etch adhesive, 2-stage total-etch adhesive, 1-stage self-etch adhesive. 각 시편들을 2% 메틸렌 블루 용액에 1주일 동안 담구었다. 세척한 시편을 자가중합 아크릴릭 레진에 포매하였다. 각 시편을 치근단, 중앙, 치관 부위로 수평 절단하였다. 메틸렌 블루가 침투된 각 시편의 절단부를 교합면 측에서 stereomicroscope로 측정하였다. 시료 침투량은 메틸렌 블루 침투 표면과 총 상아질 표면의 비율로 평가하였다. 결과: 모든 절단부위에서 모든 군들은 미세 누출을 보였다. 각 절단 부위별로 접착 시스템에 따른 포스트간의 비교에서는 유의한 차이는 없었다. All Bond 2로 접착한 3단계 접착시스템으로 처리한 치아 중앙절편에서 zirconia-glass fiber와 quarze-glass fiber 포스트 간, zirconia-glass fiber와 polyethylene fiber 포스트 간, quarze-glass fiber와 polyethylene fiber 포스트 간에 미세누출에는 유의한 차이가 있었다(P<.05). 각각의 포스트의 치근단과 치관 부위 사이에는 유의한 차이가 있었고, quarze-glass fiber와 polyethylene fiber 포스트에서 치근단과 중앙 부위 사이에 유의한 차이가 있었다(P<.05). 결론: 포스트 종류에 따른 접착 시스템 간에 미세누출의 유의한 차이가 없었다. 각 절단 부위별로 접착 시스템에 따른 포스트간의 비교에서는 유의한 차이는 없었으나, 유일하게 3단계 접착시스템으로 처리한 포스트의 중앙절편에서 zirconia-glass fiber가 다른 포스트에 비해 유의하게 적은 미세누출을 보였다.

The effect of silane applied to glass ceramics on surface structure and bonding strength at different temperatures

  • Yavuz, Tevfik;Eraslan, Oguz
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.75-84
    • /
    • 2016
  • PURPOSE. To evaluate the effect of various surface treatments on the surface structure and shear bond strength (SBS) of different ceramics. MATERIALS AND METHODS. 288 specimens (lithium-disilicate, leucite-reinforced, and glass infiltrated zirconia) were first divided into two groups according to the resin cement used, and were later divided into four groups according to the given surface treatments: G1 (hydrofluoric acid (HF)+silane), G2 (silane alone-no heat-treatment), G3 (silane alone-then dried with $60^{\circ}C$ heat-treatment), and G4 (silane alonethen dried with $100^{\circ}C$ heat-treatment). Two different adhesive luting systems were applied onto the ceramic discs in all groups. SBS (in MPa) was calculated from the failure load per bonded area (in $N/mm^2$). Subsequently, one specimen from each group was prepared for SEM evaluation of the separated-resin-ceramic interface. RESULTS. SBS values of G1 were significantly higher than those of the other groups in the lithium disilicate ceramic and leucite reinforced ceramic, and the SBS values of G4 and G1 were significantly higher than those of G2 and G3 in glass infiltrated zirconia. The three-way ANOVA revealed that the SBS values were significantly affected by the type of resin cement (P<.001). FIN ceramics had the highest rate of cohesive failure on the ceramic surfaces than other ceramic groups. AFM images showed that the surface treatment groups exhibited similar topographies, except the group treated with HF. CONCLUSION. The heat treatment was not sufficient to achieve high SBS values as compared with HF acid etching. The surface topography of ceramics was affected by surface treatments.

침투된 지르코니아-뮬라이트 복합체의 미세구조 및 기계적 성질 (Microstructure and Mechanical Properties of Infiltrated Zirconia-Mullite Composite)

  • 손영권;이윤복;김영우;오기동;박홍채
    • 한국세라믹학회지
    • /
    • 제37권2호
    • /
    • pp.174-180
    • /
    • 2000
  • Y-TZP/mullite composites were prepared by the infiltration of Y-TZP precursor into partially reaction-sintered mullite. The addition of Y-TZP(~7.2 wt%) increased the bend strength(207 MPa), fracture toughness(4.6MPa.m1/2) and Vickers microhardness(853kg/$\textrm{mm}^2$) of the uninfiltrated mullite sintered at 162$0^{\circ}C$ for 10h by more than 75, 70 and 105%, respectively. Residual alumina-rich glass was observed at a mullite/mullite junction, due to the mullitization reaction of silica melt with crystalline $\alpha$-Al2O3 during a final sintering. Although ZrO2 inclusions improved the final sintered density of mullite they did not effectively prevent its grain growth.

  • PDF