유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가 (Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors)

  • 목성윤;강영록;김효진;계용욱;안현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.

The Experience in Dose Measurement of IVR with Glass Dosimeter System

  • Nishizawa, Kanae;Moritake, Takashi;Iwai, Kazuo;Matsumaru, Yuji;Tsuboi, Koji;Maruyama, Takashi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.269-271
    • /
    • 2002
  • It is reported that exposure for the patient and the medical staff from IVR is large. Direct measurement of patient exposure is difficult, since the measurement disturbs reading of images. The fluorescence glass-dosimeter system consisting of small-size glass chips is developed in recent years. Owing to its small size and physical characteristics, direct monitoring of surface dose may be feasible. The dose measurement for patient and medical staff during head interventional radiology (IVR) examinations was tried by using the fluorescence glass-dosimeter system. A dose response of the glass dosimeter is almost linear in large dose range but its energy dependency is high. About 20% variation of sensitivity was observed in the effective energy of 45-60keV which was used in IVR. In spite of this shortcoming, the fluorescence glass-dosimeter system is a convenient means for a dose monitoring during IVR performance.

  • PDF

저에너지X선 영역에서 유리선량계의 preheat과 Non-preheat과의 시간에 따른 build up 특성에 관한 연구 (Experimental study on build up characteristic of glass dosimeter of preheat and Non-preheat in low energy according to delay time)

  • 손진현;민정환;김기원;손순륭;임현수
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3412-3418
    • /
    • 2013
  • 본 논문은 유리선량계를 이용하여 장기간에 걸쳐 방사선의 누적선량측정 시 예비가열(preheat)과정을 수행한 선량값과 예비가열을 수행하지 않은(non-preheat)선량값을 30일간 시간에 따른 선량변화와 빌드업 특성을 비교 평가함을 목적으로 하였다. 저 선량의 0.1 mGy, 1 mGy, 5 mGy의 선량을 얻기 위해 진단용 발생장치 AccuRay-650R을 사용하였다. 관전압, 관전류 조건으로 각각의 10개 총 30개의 유리선량계 GD SC-1에 조사하여 장시간에 걸쳐 빌드업 특성을 비교하였다. 예비가열을 거치지 않은 저선량의 유리선량에서 초기 판독선량값은 조사된 선량값에 미치지 못하다가 시간이 지남에 따라 점차 조사된 선량값으로 증가하는 것으로 나타냈다. 이후 실험 종료 후 예비가열을 실시한 값과 차이를 보이지는 않았으며 통계적으로도 유의한 차이는 없었다(p>0.05). 예비가열을 거친 저선량의 유리선량에서 초기 판독선량은 조사된 선량값에 근접하였고 일정한 안정상태를 보인 후 15일이 경과한 이후 부터는 점차 증가하는 것으로 나타냈다. 결론적으로 앞서 보고된 유리선량계의 특성들은 고에너지영역의 고선량에서 유리선량계의 특성들에 관한 내용으로 본 논문에서는 저에너지를 사용해서 저 선량의 누적 선량을 장시간 측정하고자 하면 예비가열을 실시하지 않고 판독을 해도 무방할 것으로 판단 사료된다.

DR(Digital Radiography)에서 PCXMC 2.0을 이용한 Kerma와 다목적 선량계, 유리선량계의 선량비교를 통한 흡수선량 평가 시 유리선량계의 유용성에 관한 연구 (A Study on the Usefulness of Glass Dosimeter in the Evaluation of Absorbed Dose by Comparing the Doses of Multi-purpose Dosimeter and Glass Dosimeter Using Kerma with PCXMC 2.0 in DR(Digital Radiography))

  • 황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.292-299
    • /
    • 2017
  • 방사선 방호는 결정적 영향을 방지하고 확률적 영향을 최소화하는데 목적이 있다. 결정적 영향과 확률적 영향을 과대평가하면 미래에 일어날 위험성에 대해 잘못된 평가를 내릴 수 있기 때문에 이들의 기본량인 흡수선량의 정확한 평가가 특히 중요하다. 본 연구는 몬테카를로 시뮬레이션을 기반으로 한 PCXMC 2.0을 이용하여 Kerma를 측정하고, 다목적 선량계 및 유리선량계를 이용하여 나타난 선량을 비교하여 정확한 흡수선량을 평가하는 것에 목적을 두었다. 실험은 부위를 두개부, 복부, 골반부로 정하였고 Kerma는 몬테카를로 시뮬레이션을 기반으로 한 PCXMC 2.0로 측정하였다. 흡수선량은 다목적 선량계와 유리선량계로 측정하였다. 그 결과 PCXMC 2.0, 다목적 선량계, 유리선량계에서 두개부, 복부, 골반부 모두 PCXMC 2.0, 다목적 선량계, 유리선량계 순으로 선량 차이가 크게 났으며, 다목적 선량계는 Kerma에 더 가까운 값을 나타냈다. 결과적으로 실제 흡수선량 측정은 유리선량계가 가장 유리하다는 것을 알 수 있었다.

엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성 (Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray)

  • 권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

반도체 선량계, 일반 선량계, 유리 선량계를 이용한 입사표면선량 모델 제시에 관한 연구: 몬테카를로 시뮬레이션 기반의 PCXMC 2.0을 통한 유효선량과 발병 위험도의 비교분석을 중심으로 (A Study on the Presentation of Entrance Surface Dose Model using Semiconductor Dosimeter, General Dosimeter, Glass Dosimeter: Focusing on Comparative Analysis of Effective Dose and Disease Risk through PCXMC 2.0 based on Monte Carlo Simulation)

  • 황준호;이경배
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.149-157
    • /
    • 2018
  • 방사선 방호의 목적 중 하나는 확률적 영향을 최소화 하는 것이다. PCXMC 2.0은 몬테카를로 시뮬레이션 기반의 프로그램으로 입사표면선량을 통해 유효선량과 암의 발병확률을 예측가능하게 해준다. 그렇기 때문에 선량계에 따른 입사표면선량 측정이 특히 중요하다. 본 연구는 반도체 선량계, 일반 선량계, 유리선량계를 통해 입사표면선량을 측정하고 그에 따른 결정 장기의 유효선량과 발병 확률을 비교분석 하는 것에 목적을 두었다. 실험방법은 두개부, 흉부, 복부의 선량계 별 입사표면선량을 측정하고 PCXMC 2.0을 통해 부위 별 결정 장기의 유효선량과 암의 발병 확률을 평가하였다. 그 결과 부위 별 입사표면선량은 동일한 조건임에도 일반 선량계, 반도체 선량계, 유리 선량계 순으로 차이가 났다. 이를 토대로 유효선량과 결정 장기의 암 발병 확률을 분석한 결과 또한 일반 선량계, 반도체 선량계, 유리 선량계 순으로 차이가 났다. 결론적으로 동일한 조건임에도 사용한 선량계에 따라 유효선량과 발병 위험도는 다르게 나타났음을 알 수 있었고, 본 연구를 통해 각각의 선량계에 따른 정확한 입사표면선량 모델을 제시하는 것이 중요하다는 것을 알 수 있었다.

A formalism for the absorbed dose evaluation of the glass dosimeter

  • Ka-Young Park;Hyun-Chul Kim;Byoung-Chul Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2283-2287
    • /
    • 2023
  • We propose in the present work how the reference glass dosimeters can be introduced, which reflects the user irradiation condition. The reference glass dosimeters are used for correcting the reader fluctuation by reading it with sample glass dosimeters at the same time. Since they can be used without annealing after irradiation for long periods, one should consider both the fading effect and the natural background dose accumulation quantitatively. We construct an empirical but practical formalism of evaluating the absorbed dose on the glass dosimeter with the fading effect and the natural background dose accumulation considered.

유리 선량계와 다이오드 측정기를 이용한 유방암 환자의 체표면 선량측정 비교 (Comparison of Skin Dose Measurement Using Glass Dosimeter and Diode for Breast Cancer Patients)

  • 고영은;박성호;최병준;김희선;노영주
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.9-13
    • /
    • 2008
  • 다이오드 측정기(diode)와 유리 선량계(glass dosimeter)를 이용하여 체표면 선량측정을 시행하고 실제 방사선조사 영역에 조사되는 방사선량을 치료계획 시스템에서 계산된 방사선량과 비교하여 유리 선량계를 체표면 측정기로 활용할 수 있는 가능성을 확인하고자 하였다. 이를 위하여 유방암 치료로 방사선을 조사받는 환자 27명을 대상으로 다이오드 측정기와 유리 선량계를 같은 부위에 부착하여 각각의 위치에서 조사되는 방사선량을 측정하였다. 여기서 사용된 유리 선량계는 총 40개 중 재현성이 3% 이내인 28개의 소자만을 사용하였다. 환자의 치료 셋업 위치에 따라 네 부위에 각각 선량계를 부착하여 각 위치에서의 선량값을 측정하였다. 연구에 참여한 27명의 환자 모두에 대하여 180 cGy/fraction의 방사선을 조사하였다. 이때 같은 부위에 부착한 두 측정기가 나타내는 선량값의 차이는 최대 3.2%였으며, 치료계획 된 선량값과 비교했을 때 다이오드 측정기의 경우 평균 2.3%의 차이를 보였으며, 유리선량계의 경우 평균 3.4%의 차이를 나타내었다. 이로써 유리 선량계는 체표면 측정기로 활용할 수 있는 가능성을 보였다. 치료계획에서 계산된 선량값에 비해 두 종류 측정기로 측정한 선량값이 모두 적은 값을 나타내었으나, 이는 각각의 선량계가 가지고 있는 특성 오차의 영향과 선량계를 부착한 부위가 고정되기 쉽지 않고 움직이기 쉬운 부분이라는 신체적 특성의 영향에 따른 차이라 생각된다.

  • PDF

진단영역 X선 에너지에서 유리선량계, 반도체선량계, 면적선량계의 선량 실측 비교 (Comparison of Dose Measurement of Glass Dose Meter, Semiconductor Dose Meter, and Area Dose Meter in Diagnostic X-ray Energy)

  • 손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.483-489
    • /
    • 2019
  • This paper obtained and compared these dose values by setting and comparing the X-ray imaging conditions (tube voltage 60 kVp, 70 kVp, 80 kVp, tube current 10 mAs, 16 mAs and X-ray field size are 10 × 10 cm, 15 × 15 cm). Each dose value was measure 10 times and represented as an average value. The purpose of this experiment is to serve as a reference for the X-ray exposure of diagnostic areas according to the type of dosimeter and to help with another dose measurement. The results of the experiment showed very little difference between the glass dosimeter(GD) and semiconductor dosimeter values due to changes in tube voltage of 60, 70, 80 kVp, regardless of field sized, but for dose area product(DAP), the difference in dose value was significant according to field size.