• 제목/요약/키워드: Glass Ionomer Cement

검색결과 226건 처리시간 0.023초

35% 과산화수소를 함유한 치아미백제가 심미수복재의 색, 미세경도 및 표면 거칠기에 미치는 영향 (The effect of tooth bleaching agent contained 35% hydrogen peroxide on the color, microhardness and surface roughness of tooth-colored restorative materials)

  • 심연수
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.533-541
    • /
    • 2012
  • Objectives : The purpose of this study was to evaluate the effects of tooth bleaching agent contained 35% hydrogen peroxide on the color, microhardness and surface roughness of tooth-colored restorative materials. Methods : Four types of tooth-colored restorative materials, including a composite resin(Filtek Z350 ; Z350), a flowable composite resin(Filtek P60 : P60), a compomer(Dyract$^{(R)}$ AP ; DY), and a glass-ionomer cement(KetacTM Molar Easymix ; KM) were used in the study. The specimens($8mm{\times}5mm$) were made by using a customized acrylic mold. Each material was divided into two groups equally(n=40) : experimental group(35% HP) and control group(distilled water). 35% HP group was treated 30 mim/5 days for 15 days. Each 30 minute treatment session consisted of two 15 minute cycles of gel application with 20 second light exposure. The authors measured the color, microhardness, and roughness of the specimens before and after bleaching. The data were analyzed with ANOVA and T-test. Results : 35% HP group showed an apparent color change(${\Delta}E^*$) than control group. In particular, DY and KM showed a noticeable color change and statistically significant differences(p<0.05). 35% HP group showed a reduction in microhardness. Z350 and P60 does not have a statistically significant difference(p>0.05), DY and KM showed a statistically significant difference(p<0.05). Percentage microhardness loss(PML) of control group was 0.6 to 5.5% in the group, 35% HP group was 6.6 to 34.6%. Roughness was increased in 35% HP group after bleaching. Especially DY and KM were significantly increased(p<0.05). Conclusions : Bleaching agents may affect the surface of existing restorations; therefore, they should not be used indiscriminately when tooth-colored restorations are present.

지대치 코어 재료와 In-Ceram coping의 두께가 In-Ceram의 색에 미치는 영향 (COLOR DIFFERNCE OF IN-CERAM BY THE VARIOUS POSTCORE MATERIALS AND COPING THICKNESS)

  • 심직현;방몽숙
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.634-644
    • /
    • 1995
  • The purpose of this study is to evaluate the color differences in the In-Ceram according to coping thickness and various abutment core materials ; amalgam, precious alloy, composite resin, non-precious alloy. After the porcelain was built up on the In-Ceram coping at the thicknes of 0.3mm and 0.5mm then it was cemented with glass ionomer cement to the post & core materials. The following results were obtained. 1. There were significant differences in the $L^*$ values $a^*$ and $b^*$ values in the cementation of different cores, to the In-Ceram(P<0.01). $L^*$ values were not significantly different between the composite resin to the In-Ceram and the $a^*\;b^*$ values were not significantly different between the amalgam and the non-precious alloy. 2. All of cementations of In-Ceram to the core materisal had color difference(${\Delta}E^*ab$) compared to the In-Ceram. In the 0.3mm thickness of the In-Ceram copping non-precious alloy indicated the greatest value, while the composite resin core showed the lowest value with a thickness of 0.5mm In-Ceram copping. 3. By controlloing the In-Ceram coping thickness $L^*$ value was significatly different(P<0.01), but not in $a^*$ and $b^*$ values. 4. In an amalgam, precious & non-prcious alloys there was a 1,74 to 3.06 range color difference in the controlled thickness of In-Ceram coping at the thickness of 0.3mm and 0.5mm. The above results suggest that the requirement of the sufficient thickness of In-Ceram coping and the suitable core material in order to get an estheti restoration by In-Ceram and also to intercept the original core color.

  • PDF

치과용 수복재료에 따른 유구치부 인접면 수복물의 생존율연구 : 후향적연구 (Retrospective Study of Survival Rates According to the Type of Dental Restoration of Proximal Caries in Primary Molars)

  • 지명관;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제42권3호
    • /
    • pp.249-256
    • /
    • 2015
  • 최근 수복용 치과재료는 물리적 성질의 개선과 함께 빠르게 발전하였고 이에 따라 다양한 재료의 선택이 가능하게 되었다. 유구치 우식 수복을 위하여 아말감, 복합레진, 그리고 기성금속관이 널리 사용되어 왔으며, 최근 물성이 강화된 글라스아이오노머 시멘트가 수복재로서 사용되고 있다. 유구치부 인접면 우식증 치료에 사용되고 있는 수많은 치과용 재료들은 각각 뚜렷한 장단점을 가지고 있지만 이의 생존율에 관한 연구는 많지 않다. 이에 본 논문은 유구치의 2급 수복물에 있어서 생존율을 평가하고, 각 수복물의 종류에 따른 합병증들을 조사하여 비교 해보고자 한다. 본 논문은 700개가 넘는 표본을 조사하여, 현재 소아치과의사들에게 가장 큰 고민 중 하나인 구치부 2급 수복물의 선택에 대해 고려해볼 수 있는 결과를 도출하였다.

Hybrid-Ceramic Crown과 금속 도재관의 파절강도 비교 (COMPARISON OF FRACTURE STRENGTH BETWEEN HYBRID-CERAMIC CROWN AND METAL-CERAMIC CROWN)

  • 구철회;양홍서
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.14-24
    • /
    • 2001
  • The purpose of this study was to compare the fracture strengths and the fracture patterns of several hybrid-ceramic crowns and metal-ceramic crown. Ten crowns were constructed for each group according to the manufacturer's instruction. Removable template of silicone rubber impression material was used for standardization of each crowns. Each crown was cemented on a metal die with hybrid glass ionomer cement. All crowns cemented were stored in distilled water, $36^{\circ}C$ for 24 hours prior to loading in an universal testing machine. The load was directed at 130 degrees the long axis of metal die. The fracture strengths were measured and the fracture patterns were observed. The following results were obtained from this study 1. The mean fracture strengths of $Artglass^{(R)}$, $Sculpture^{(R)}$ and $Targis^{(R)}$ were $57.5{\pm}9.5Kgf,\;62.7{\pm}12.2Kgf$ and $60.2{\pm}10.1Kgf$ respectively. There was no significant difference among each hybrid ceramic crown group. 2. The toad required to fracture hybrid-ceramic crowns was significantly smaller than metal-ceramic crowns($131.7{\pm}22.0Kgf$). 3. In the metal-ceramic crowns, labial porcelain detached partially from porcelain-metal junction of proximal side by load. 4. Hybrid-ceramic crowns showed a simple fracture pattern that fracture line began at the loading area and extended through proximal surface, perpendicular to the margin. The crown was separated into two parts of labial side and lingual side. Above results revealed that three kinds of the hybrid-ceramic crowns used in this study must have careful application in clinical use since the strength of hybrid-ceramic crown was lower(about 1/2) than that of metal-ceramic crown.

  • PDF

Fracture resistance of upper central incisors restored with different posts and cores

  • Rezaei Dastjerdi, Maryam;Amirian Chaijan, Kamran;Tavanafar, Saeid
    • Restorative Dentistry and Endodontics
    • /
    • 제40권3호
    • /
    • pp.229-235
    • /
    • 2015
  • Objectives: To determine and compare the fracture resistance of endodontically treated maxillary central incisors restored with different posts and cores. Materials and Methods: Forty-eight upper central incisors were randomly divided into four groups: cast post and core (group 1), fiber-reinforced composite (FRC) post and composite core (group 2), composite post and core (group 3), and controls (group 4). Mesio-distal and bucco-lingual dimensions at 7 and 14 mm from the apex were compared to ensure standardization among the groups. Twelve teeth were prepared for crown restoration (group 4). Teeth in other groups were endodontically treated, decoronated at 14 mm from the apex, and prepared for posts and cores. Resin-based materials were used for cementation in groups 1 and 2. In group 3, composite was used directly to fill the post space and for core build-up. All samples were restored by standard metal crowns using glass ionomer cement, mounted at $135^{\circ}$ vertical angle, subjected to thermo-mechanical aging, and then fractured using a universal testing machine. Kruskal-Wallis and Mann-Whitney U tests were used to analyze the data. Results: Fracture resistance of the groups was as follows: Control (group 4) > cast post and core (group 1) > fiber post and composite core (group 2) > composite post and core (group 3). All samples in groups 2 and 3 fractured in restorable patterns, whereas most (58%) in group 1 were non-restorable. Conclusions: Within the limitations of this study, FRC posts showed acceptable fracture resistance with favorable fracture patterns for reconstruction of upper central incisors.

주근단공의 조건에 따른 Root ZX의 정확성 평가 (An evaluation of the accuracy of Root ZX according to the conditions of major apical foramen)

  • 박신영;이동균;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.68-73
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the accuracy of Root ZX (J. Morita Corp.) according to the location of major foramen and open apex. Materials and Methods: 81 mandibular premolars with mature apices were selected. After access preparation, 27 teeth were instrumented to simulate open apices. 54 teeth were classified according to location of major foramen under surgical microscope (${\times}16$). The file was fixed at the location of apical constriction by Root ZX using glass ionomer cement .The apical 4 mm of the apex was exposed and photo was taken and the distance from file tip to the major foramen was measured by calibrating metal ruler on graph paper. The results were statistically analyzed using ANOVA and Scheffe test at p < 0.05 level. Results: Mean distance from file tip to major foramen was 0.308 mm in Tip foramen group (I), 0.519 mm in Lateral foramen group (II) and 0.932 mm in open apex group (III). Root ZX located apical constriction accurately within ${\pm}0.5mm$ in group I of 85.71%, in group II of 59.09%, and in group III of 33.33%. There was a statistically significant difference between group I and III (p < 0.05). Conclusion: Root ZX located apical constriction accurately regardless of location of major foramen. However, Root ZX couldn't find it in open apex. Clinicians have to use a combination of methods to determine an appropriate working length at open apex. It may be more successful than relying on just electronic apex locator.

치과용 접착제를 사용한 접착 아말감의 결합 강도 (BOND STRENGTH OF BONDED AMALGAM USING DENIAL ADHESIVES)

  • 감동훈;이상대;한세현
    • 대한소아치과학회지
    • /
    • 제26권2호
    • /
    • pp.284-295
    • /
    • 1999
  • 아말감의 단점인 건전 치질 삭제와 미세 누출을 줄이기 위한 접착 아말감(bonded amalgam)에 사용되는 치과용 접착제의 접착 강도를 측정하고 파절면을 관찰하여 콤포지트 레진과 비교 평가하였다. 발거한 우전치의 순면을 직경 8mm의 원형으로 천공하여 얻은 부분을 순면이 바깥쪽으로 향하도록 아크릴릭 레진 블록에 매몰하여 상아질과 법랑질군을 각각 55개씩 준비하였다. 1군:Superbond C&B, 2군:Panavia 21, 3군:All-Bond 2, 4군:Fuji I Glass Ionomer Luting Cement, 5군:Scotchbond Multi-Purpose(Restorative Z-100)의 5개 군으로 나누어 지름 6.3mm, 깊이 1.5mm의 구멍이 뚫린 충전용 틀(mold)을 위치시키고 표면을 접착제로 처리한 후 아말감 충전을 하였다. 5군은 레진 충전 후 40초간 광중합하였다. 각 시편은 아말감 충전 24시간 후 접착 강도 측정용 기구에 장착하고 만능 시험기에서 0.2mm/min의 cross-head 속도로 하중을 가하여 시편이 탈락할 때까지의 하중값(kg)을 측정하고, 파절면을 검사하여 다음과 같은 결론을 얻었다. 1. 상아질군에서 1, 2, 4군은 5군에 비하여 통계학적으로 유의성 있게 낮은 접착 강도를 보였다(P<0.05). 2. 법랑질군에서 4군은 5군에 비하여 통계학적으로 유의성 있게 낮은 접착 강도를 보였다(P<0.05). 3. 2군에서는 상아질군에서 법랑질군에 비하여 통계학적으로 유의성 있게 낮은 접착 강도를 보였으나(P<0.05), 다른 접착제에서는 상아질군과 법랑질군에서의 접착 강도가 유의성 있는 차이를 보이지 않았다(P>0.05). 4. Cohesive failure는 1E군과 5D군에서 관찰되었고, mixed failure는 1, 5군에서 관찰되었으며, 2, 3, 4군에서는 adhesive failure만 관찰되었다.

  • PDF

기저재용 광중합형 글래스아이오노머의 치질 및 복합 레진 인레이에 대한 접착양상 (STUDY ON THE INTERFACE BETWEEN LIGHT-CURED GLASS IONOMER BASE AND INDIRECT COMPOSITE RESIN INLAY AND DENTIN)

  • 이송희;김동준;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제30권3호
    • /
    • pp.158-169
    • /
    • 2005
  • 본 연구는 간접 복합 레진 인레이 수복 시 기저재로 사용되는 광중합형 글래스아이오노머와 인레이 접착에 사용되는 레진 시멘트간의 접착 전까지의 시간 경과에 따른 전단 결합강도를 측정하고, 상아질과 글래스아이오노머, 글래스아이오노머와 레진 시멘트간 접착계면에 대해 SEM 관찰하였다. 2종의 광중합형 글래스아이오노머 시멘트 Fuji II LC (GC Co, Tokyo, Japan)와 Vitrebond$^{TM}$ (3M, Paul, Minnesota, U.S.A)의 시편을 제작하였다 5 mmx7 mm의 실리콘 주형에 Artglass$^{(R)}$ (Heraeus Kultzer, Germany)를 이용하여 레진 인레이를 제작하였다. 글래스아이오노머 베이스를 각 각 1시간, 24시간, 1주 및 2주 동안 37$^{\circ}C$ 증류수에 보관한 후 Variolink$^{(R)}$ II (Ivoclar Vivadent, Liechtenstein)를 적용하여 인레이를 접착하였다. 만능 물성시험기(Model 4302, Instron, U.S.A)를 이용하여 결합 면에 1 mm/min의 속도로 1000 kg 하중을 가하여 전단 결합강도를 측정하였고, one-way ANOVA를 이용하여 통계 분석하였다. SEM 관찰을 위해 발거된 제 3대구치에 2급 와동을 형성하였고, 기저재로 광중합형 글래스아이오노머 시멘트를 적용하였다. 인레이를 접착한 시편을 수직 절단하여 상아질, 글래스아이오노머, 및 복합레진 인레이 간의 계면을 SEM (JSM-5400$^{(R)}$ Jeol, Tokyo, Japan) 관찰하였다. 시간 경과에 따른 글래스아이오노머와 복합 레진 인레이 사이의 전단 결합강도는 통계학적으로 유의한 차이가 없었으며, 기저재 재료에 따른 전단 결합강도의 유의한 차이도 없었으며 대부분 시편에서 글라스아이오노머 내부에서 응집 파괴 (Cohesive failure)가 발생하였다. SEM 관찰 시 글래스아이오노머와 상아질 사이에 약 30-20 $\mu$rn 정도의 간극 (gap)이 형성되었으며 , 글래스아이오노머와 복합 레진 인레이 계면에서는 1시간 후 접착한 시편을 제외하고 간극은 발견되지 않았다.

수종의 밴드 접착 시멘트의 물성에 대한 비교 연구 (COMPARATIVE STUDY OF PHYSICAL PROPERTIES FOR VARIOUS BAND CEMENTS)

  • 양규호;김기백;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제36권3호
    • /
    • pp.427-432
    • /
    • 2009
  • 본 연구의 목적은 시중에 유통되고 있는 밴드 시멘트들을 종류별로 이용하여 교정용 밴드의 결합강도를 비교하고, 각 시멘트의 파절 양상을 비교하여 교정용 밴드에 대한 사용지침을 마련하는데 도움이 되고자 하였다. 100개의 발거된 인간의 제 3대구치를 이용해 실험군은 총 5개의 군으로 하였으며, 각 군당 시편수가 20개가 되도록 임의적으로 분류하였다. 실험에 사용한 밴드 시멘트는 다음과 같다; Ormco gold, Ultra $Band-Lok^{TM}$, Fuji $Ortho^{TM}$ LC, 3M $Unitek^{TM}$ Multi-Cure Glass Ionomer, $Ketac-Cem^{TM}$. Universal testing machine(Instron Corp., Canton, MA, USA)를 사용하여 최대하중값을 측정하였고, 전단결합강도 값을 계산하였다. 밴드가 탈락한 후, 탈락 부위를 평가하여 법랑질과 시멘트, 시멘트와 밴드 사이로 구분하였다. 밴드의 전단강도는 One-way ANOVA를 이용하여 통계처리 하였으며 Tukey test를 이용하여 검정하였다. 또한 탈락 부위는 Chi-squre analysis를 이용하여 통계 처리하였고, Fisher's exact test로 군간 유의성을 검정하였다. 실험 결과 평균 파절 강도는 Ormco군이 가장 높았고(2.44${\pm}$0.57), Fuji $Ortho^{TM}$군(2.24${\pm}$0.50), $Ketac-Cem^{TM}$군(2.10${\pm}$0.57), 3M $Unitek^{TM}$군(1.82${\pm}$0.43), $Band-Lok^{TM}$군(1.73${\pm}$0.28) 순이었으며, Ormco군은 $Band-Lok^{TM}$군과 3M $Unitek^{TM}$군, Fuji $Ortho^{TM}$군은 $Band-Lok^{TM}$군과만 통계적으로 유의할만한 차이를 보였다(p<0.05). 파절 양상에서 Ormco군과 $Band-Lok^{TM}$군은 서로뿐만 아니라 다른 군과 유의할만한 차이를 보였으며, Fuji $Ortho^{TM}$, 3M $Unitek^{TM}$, $Ketac-Cem^{TM}$ 군 간에는 유의한 차이가 없었다.

  • PDF

주조 포스트코아에서 시멘트 종류가 미세누출에 미치는 영향 (A Study of the Comparison of Microleakage according to the Types of Cement on the Cast Post and Core)

  • 남기영;이청희;조광헌
    • 구강회복응용과학지
    • /
    • 제16권1호
    • /
    • pp.51-60
    • /
    • 2000
  • 주조 포스트코아와 치질 계면에서 시멘트 종류에 따른 미세누출의 변화를 알아보기 위해 상악 전치부 및 하악 견치, 총 40개의 단근치를 백악-법랑 경계 2mm 상방에서 절단하고 백악-법랑 경계 1mm 상방에 chamfer 변연 형성 후, 통상적 근관 형성, 및 충전을 시행하고 주조용 Parapost를 이용하여 40개의 주조 포스트코아를 제작하였다. 각 군당 10개씩 4군으로 분배하여, 실험 I군에서는 인산아연 시멘트인 Fleck's를, 실험 II군에서는 글래스아이오노머 시멘트인 Fuji I을, 실험 III군에서는 4-META계 레진 시멘트인 Superbond C & B를, 실험 IV군에서는 인산 에스테르계 레진 시멘트인 Panavia 21로 각각 접착한 다음, 500회 thermocycling 및 1% basic fuchsin 염색액 침액을 거친 후 시편을 협설면으로 절단하고 광학 현미경상에서 포스트와 치질 계면사이의 미세누출정도를 지수로 산정하여 시편 협설면의 지수 평균을 계산한 후 각 군간의 비교 분석을 통해 다음과 같은 결론을 얻었다. 1. 모든 시편의 계면에서 미세누출이 관찰되었다. 2. 실험 I군에서 실험 II군, 실험 III군, 및 실험 IV군에 비해 유의성있게 가장 높은 미세누출지수를 보였고, 실험 II군에서 실험 III군, 및 실험 IV군에 비해 유의성있게 높은 미세누출지수를 보였다(p<0.05). 3. 실험 IV군에서 가장 낮은 미세누출지수를 보였으나 실험 III군과의 통계학적 차이는 없었다(p>0.05).

  • PDF