• Title/Summary/Keyword: Glass Filter

Search Result 221, Processing Time 0.032 seconds

High Precision Path Generation of an LCD Glass-Handling Robot

  • Cho, Phil-Joo;Kim, Hyo-Gyu;Kim, Dong-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2311-2318
    • /
    • 2005
  • Progress in the LCD industries has been very rapid. Therefore, their manufacturing lines require larger LCD glass-handling robots and more precise path control of the robots. In this paper, we present two practical advanced algorithms for high-precision path generation of an LCD glass-handling robot. One is high-precision path interpolation for continuous motion, which connects several single motions and is a reliable solution for a short robot cycle time. We demonstrate that the proposed algorithm can reduce path error by approximately 91% compared with existing algorithms without increasing cycle time. The second is real-time static deflection compensation, which can optimally compensate the static deflection of the handling robot without any additional sensors, measurement instruments or mechanical axes. This reduces vertical path error to approximately 60% of the existing system error. All of these algorithms have been commercialized and applied to a seventh-generation LCD glass-handling robot.

  • PDF

Suppression of Moiré Fringes Using Hollow Glass Microspheres for LED Screen (중공 미소 유리구를 이용한 LED 스크린 모아레 억제)

  • Songeun Hong;Jeongpil Na;Mose Jung;Gieun Kim;Jongwoon Park
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.28-35
    • /
    • 2023
  • Moiré patterns emerge due to the interference between the non-emission area of the LED screen and the grid line in an image sensor of a video recording device when taking a video in the presence of the LED screen. To reduce the moiré intensity, we have fabricated an anti-moiré filter using hollow glass microspheres (HGMs) by slot-die coating. The LED screen has a large non-emission area because of a large pitch (distance between LED chips), causing more severe moiré phenomenon, compared with a display panel having a very narrow black matrix (BM). It is shown that HGMs diffuse light in such a way that the periodicity of the screen is broken and thus the moiré intensity weakens. To quantitatively analyze its moiré suppression capability, we have calculated the spatial frequencies of the moiré fringes using fast Fourier transform. It is addressed that the moiré phenomenon is suppressed and thus the amplitude of each discrete spatial frequency term is reduced as the HGM concentration is increased. Using the filter with the HGM concentration of 9 wt%, the moiré fringes appeared depending sensitively on the distance between the LED screen and the camera are almost completely removed and the visibility of a nature image is enhanced at a sacrifice of luminance.

  • PDF

Investigation on Lead-Borosilicate Glass Based Dielectrics for LTCC (Lead-Borosilicate Glass계 LTCC용 유전체에 대한 고찰)

  • Yoon, Sang-Ok;Oh, Chang-Yong;Kim, Kwan-Soo;Jo, Tae-Hyun;Shim, Sang-Heung;Park, Jong-Guk
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.6 s.289
    • /
    • pp.338-343
    • /
    • 2006
  • The effects of lead-borosilicate glass frits on the sintering behavior and microwave dielectric properties of ceramic-glass composites were investigated as functions of glass composition of glass addition ($10{\sim}50vol%$), softening point (Ts) of the glass, and sintering temperature of the composites ($500{\sim}900^{\circ}C$ for 2 h). The addition of 50 vol% glass ensured successful sintering below $900^{\circ}C$. Sintering characteristics of the composites were well described in terms of Ts. PbO addition in to the glass enhanced the reaction with $Al_{2}O_3$ to form liquid phase and $PbAl_{2}Si_{2}O_8$, which was responsible to lower Ts. Dielectric constant(${\epsilon}_r$), $Q{\times}f_0$ and temperature coefficient of resonant frequency (${\tau}_f$) of the composite with 50 vol% glass contents ($B_{2}O_{3}:PbO:SiO_{2}:CaO:Al_{2}O_3$ = 5:40:45:5:5) demonstrated 8.5, 6,000 GHz, $-70\;ppm/^{\circ}C$, respectively, which is applicable to substrate requiring a low dielectric constant. When the same glass composition was applied sinter $MgTiO_3\;and\;TiO_2,\;at\;900^{\circ}C$ (50 vol% glass in total), the properties were 23.8, 4,000 GHz, $-65ppm/^{\circ}C$ and 31.1, 2,500 GHz, $+80ppm/^{\circ}C$ respectively, which is applicable to filter requiring an intermidiate dielectric constant.

Determination of Optimal Combination of Optical Filter for Recognizing Financial Account Using Statistical Analysis (통계적 분석에 의한 금융통장 인식용 광학필터 최적 조합 선정에 관한 연구)

  • Yu, Hyeung Keun;Lee, Kang Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.328-341
    • /
    • 2014
  • The object of this paper is to develop optimal optical filter, which can be used to identify the financial account and read the information. The five factors which affect the performance of the optical filter are identified as optical glass type, existence of Fe, Photo pic coating type, and coating form. In this study we seek to determine the optimal combination for the best design of the optical filter. For each combination, the performances of optical filter are investigated using the proper experimental equipments and methods. White-state voltage, black-state voltage, and black-state error rate are used for the performance measures. Through the statistical analysis of the performance data collected, we have determined the optimal design of the optical filter.

Performance Test of Ceramic Filter Collector for the heavy-oil boiler for Concurrent treatment Dust and Nitrogen Oxides (분진 및 질소산화물 동시처리를 위한 1톤 중유 보일러용 세라믹 필터 집진기의 성능실험)

  • Jung, Wan-Bo;Cho, Jung-Sick
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.355-360
    • /
    • 2018
  • The product developed in this study is a ceramic catalyst filter for 1 ton heavy-oil boiler that can simultaneously process dust and nitrogen oxides. This has been developed for simultaneous processing of nitrogen oxides and dust at high efficiency of hot exhaust gas (approximately $300^{\circ}C$) generated after burning 1 ton heavy oil boiler. Ceramic catalytic filters for 1 tonne heavy-duty glass display are technologies that remove 90% of dust and 85% or more of nitrogen oxides. This is an improved new technology to integrate exhaust ventilation and desiccation devices into one, thereby reducing the production process and improving the economy. To this end, the performance test of the catalytic filter for heavy oil boilers was carried out, and the durability of the PLC circuit was constructed.

Study on the Filter Collection Methods of Ammonia and Ammonium Salts in the Atomosphere (대기중의 암모니아 및 암모늄염의 필터포집법에 관한 연구)

  • Hui Kang Kim;橋本芳一;Yong Keun Lee
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.36-42
    • /
    • 1982
  • Filters were evaluated to use in the collection of ammonia and ammonium salts in the atmosphere. Ammonia from standard gas generator was collected on a glass fiber filter impregnated with a mixture of 3% boric acid and 25% glycerin. The collection efficiency by the impregnated filter was 96.4${\pm}$2.15% in pH control method and 97.4${\pm}$1.06% in the atmosphere for five measurements, respectively. Adsorption and desorption of gaseous ammonia were compared using three commercially available filters; glass fiber, quartz fiber and polycarbonate filters. Both glass and quartz fiber filters indicated some loss of ammonium salts and adsorption of ammonia, respectively. However, polycarbonate filter was found to be satisfactory for the collection of ammonium salts in the atmosphere. The minimum measurable concentration of ammonia was 0.83ppb (ca. 0.63${\mu}g$/$m^3$) by spectrophotometry of the indophenol method for the sample collected by 47mm${\phi}$ filter(20l/min, 60min). The sensitivity of the present method is about 20 folds higher than that of conventional method of bubbler collection followed by spectrophotometry, so that this method makes it possible to measure thevariation of ammoniacal concentrations in the atmosphere for a short time period of about 60 min.

  • PDF